Troubleshooting by Remote Controller
Si20-701_B
471
Pressure Sensor for except RZQ(S)-B, RZQ-C7 and
CMSQ
P
H
= 1.38VH-0.69
P
H
: High pressure (MPa)
V
H
: Output Voltage [High Side] VDC
High Pressure (P
H
)
This graph is available for both high pressure sensor
and low pressure sensor.
Output Voltage (V
H
)
Detected Pressure