PROCEDURE

S E R V I C E   M A N U A L

Outdoor Unit

Non-Inverter

Pair Type

15000 Btu/h Class

Si011186

Содержание R15LV2S

Страница 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Outdoor Unit Non Inverter Pair Type 15000 Btu h Class Si011186 ...

Страница 2: ...Service Manual Removal Procedure Outdoor Unit Applicable Model zCooling Only R15LV2S ...

Страница 3: ...Removal Procedure 1 Table of Contents 1 Removal of Outer Panels Fan Motor 2 2 Removal of Electrical Component ASSY 10 3 Removal of Sound Blanket 11 4 Removal of Capillary Tube 12 5 Removal of Compressor ASSY 13 ...

Страница 4: ...assembling work Step Procedure Points 1 Appearance features Take care not to cut your finger by the fins of the outdoor heat exchanger 2 Remove the panels The stop valve cover is united with the shield plate When reassembling make sure to fit the 5 hooks 1 Remove the screw of the stop valve cover Pull down the stop valve cover and remove it R15226 R16332 Stop valve cover R7188 Shield plate Hook R1...

Страница 5: ...r Panels Fan Motor Removal Procedure 3 2 Remove the 3 screws and remove the top panel 3 Remove the 4 screws and remove the discharge grille The discharge grille has 4 hooks Step Procedure Points Top panel R16334 R16335 R16336 ...

Страница 6: ...s Fan Motor Si011186 4 Removal Procedure 4 Remove the 8 screws and remove the front panel 5 Unfasten the hooks Pull and remove the front panel The front panel has 4 hooks Step Procedure Points R16337 Front panel Hook R16338 ...

Страница 7: ...utdoor fan 2 Remove the outdoor fan Align the mark of the outdoor fan with the D cut section of the motor shaft when reassembling 3 Disconnect the fan motor relay connector 4 Release the fan motor lead wire from the hook Step Procedure Points R15230 Outdoor fan 10 mm R12236 D cut R7197 Hook Fan motor relay connector R16404 ...

Страница 8: ...n motor fixing frame Put the fan motor lead wire through the back of the fan motor when reassembling so as not to be entangled with the outdoor fan When reassembling fit the lower hooks into the bottom frame Step Procedure Points R16414 Fan motor fixing frame R16415 R3249 Lead wire Outdoor fan R7206 ...

Страница 9: ...i011186 Removal of Outer Panels Fan Motor Removal Procedure 7 6 Release the fan motor lead wire from the hooks 7 Remove the 4 screws and remove the fan motor Step Procedure Points R16416 R15235 Fan motor ...

Страница 10: ...Remove the 7 screws and disconnect the connecting wire and the power supply wire 2 Remove the screw and remove the wire clamp 3 Lift up and remove the guard net 4 Remove the 2 screws on the rear side Step Procedure Points Connecting wire Wire clamp R16417 Power supply wire Guard net R8284 R15237 ...

Страница 11: ...Remove the 4 screws on the right side 6 Remove the screw near the connection port 7 Unfasten the hook of the right side panel When reassembling make sure to fit the hook 8 Remove the right side panel Step Procedure Points R15238 Right side panel R16418 R15240 R16405 ...

Страница 12: ... Procedure Points 1 Pull out the terminal blue for compressor from K1M 1 2 Pull out the 2 terminals red yellow from the compressor capacitor C1R Compressor lead wire S W yellow C U blue R V red 3 Remove the electrical component ASSY 2 4 6 14 A2 1 3 5 13 A1 K1M to compressor C terminal blue R17468 C1R R17469 to compressor R terminal red to compressor S terminal yellow S W C U R V R15393 K1M C2R F1U...

Страница 13: ...tep Procedure Points 1 Untie the 2 strings and open the sound blanket Preparation Remove the outer panels according to the Removal of Outer Panels Fan Motor Remove the electrical components ASSY according to the Removal of Electrical Components ASSY 2 Remove the sound blanket Since the piping ports on the sound blanket are torn easily remove the sound blanket carefully R16419 Sound blanket body R1...

Страница 14: ...rant gas in the atmosphere Make sure to collect all the refrigerant gas Cautions for restoration 1 Restore the piping by non oxidation brazing 2 Avoid excessive heating Keep below 120 C In case of difficulty with gas brazing machine 1 Disconnect the brazed part where is easy to disconnect and restore 2 Cut pipes on the main unit with a tube cutter in order to make it easy to disconnect 1 Remove th...

Страница 15: ...ait for 10 minutes or more after turning off all power supplies before disassembling work Step Procedure Points 1 Remove the nut and remove the terminal cover 2 Disconnect the compressor lead wires S W yellow C U blue R V red 3 Remove the 3 nuts of the compressor R15244 Terminal cover R15245 S W C U R V R15393 R15442 ...

Страница 16: ...tions for restoration 1 Restore the piping by non oxidation brazing 2 Avoid excessive heating Keep below 120 C In case of difficulty with gas brazing machine 1 Disconnect the brazed part where is easy to disconnect and restore 2 Cut pipes on the main unit with a tube cutter in order to make it easy to disconnect 4 Heat up the brazed part of the discharge side and disconnect 5 6 Heat up the brazed ...

Страница 17: ...Revision History Month Year Version Revised contents 08 2012 Si011186 First edition ...

Страница 18: ...ories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage electrical shock fire or explosion z Read the User s Manual carefully before using this product The User s Manual provides important safety instruct...