9
|
Appendix B – About commissioning in case of Proxy Server
Installer reference guide
40
MCS341-DS1-111
Security gateway
4P529063-1A – 2020.12
INFORMATION
If the IP address (IP address), default gateway (Default gateway) and primary DNS
(Primary DNS) are according to the conditions of the local network, you do not need
to change them.
3
Click the Save (Save) button.
Result:
The confirm (Confirm) dialog appears.
4
Click the Yes (Yes) button to reboot the Security gateway.
Result:
This will reboot the Security gateway.
Result:
The web browser window appears.
Result:
The IP address will be changed.
INFORMATION
The web browser communication will be lost once step 4 is executed. Follow the
procedure as described in
"To access the Security gateway"
15] to reconnect by
using the new IP address.
5
Reset the LAN network settings of your computer to their original values.
6
If you disabled it before, enable the WiFi adapter of your computer.
7
Disconnect the Ethernet cable between your computer and the Security
gateway module.
8
Connect an Ethernet cable between the Security gateway module and the
local network.
F1, F2
OUT
IN
F1, F2
e
g
h
f
d
c
b
a
9.4 To set up the time zone of the Security gateway