58
AGZ 025D through 190D
OMM 1087
Continued next page.
Screen Cx-3
From Screen U-10, U-11
Circuit x Manual Control
No password
Operator
Links to screen
Test Fan Output 2
Test Fan Output 3
Test Fan Output 4
Test Fan Output 5
Test Fan VFD Speed
Input/Output Values
Circuit Switch Input State
MHP Switch Input State
Motor Protector Input State
PVM/GFP Input State
Evaporator Pressure Input Voltage
Condenser Pressure Input Voltage
Suction Temp Input Resistance
Compressor 1/2 Output State
Compressor 3/4 Output State
Compressor 5/6 Output State
Liquid Line Solenoid Output State
Hot Gas Bypass Output State
Fan Output 1 State
Fan Output 2 State
Fan Output 3 State
Fan Output 4 State
Fan Output 5 State
Fan VFD Speed
Screen Cx-4
From Screen Cx-1
Data
No password
Operator
Links to screen
Evaporator Pressure
*
Condenser Pressure
*
Saturated Evap Temperature
*
Saturated Cond Temperature
*
Suction Temperature
*
Suction Superheat
*
Evaporator Approach
*
Evaporator Design Approach
*
Condenser Approach
*
Condenser Design Approach
*
EXV Position
*
Evap Leaving Water Temp
Evap Entering Water Temp
Screen Cx-5
From Screen Cx-1
Status/Settings Cirx
No password
Operator
Links to screen
Circuit Status
R
*
Circuit Mode
R
*
Circuit Capacity
R
*