background image

29

Maintenance

Maintenance

 WARNING

Before cleaning and maintenance work, be sure to unplug 
the unit. (An electric shock or injury may result)

Humidifying Tray 

Wash/Rinse

About every 3 days or when odour or dirt becomes 
an issue

Clean with water.

•  Use a soft cloth or brush to clean hard-to-reach places.
•  For areas with water scales, remove the water scales with 

a soft cloth or brush soaked in lukewarm or room 
temperature water in which citric acid has been dissolved.

When removing water scales, be careful not to get 

the silver ion cartridge wet.

Finally, rinse with water.

•  Citric acid may be purchased at a pharmacy, drug store 

or super market.

Note

Depending on water quality and the usage environment, 
water in the humidifying tray may become discoloured due 
to water scales etc. Clean it also in such cases.

Attention

Silver ion cartridge

• 

Do not remove.

• 

Do not clean with citric acid or baking soda.

Loss of the capacity for slime-resistance will result.

Float

• 

Do not remove. 

Humidifying operation will become 
impossible.

If the fl oat detaches from the tray

1   Place the fl oat protrusion 

onto the tray protrusion

2   Insert the axle on the fl oat 

protrusion side into the hole 
of the tray

3   Insert the axle into the hole 

of the tray

2

1

3

Protrusion on tray

Sectional view

Float

•  Fill the tray with water and check 

that the fl oat rises to the water 
surface. 

•  After checking, be sure to discard 

the water, then attach the 
humidifi cation tray to the unit.

Removing the humidifying tray and 

humidifying fi lter unit

1. 

Take out the water tank from the main unit. 

Page 12

2. 

Remove the humidifying tray and then remove 

the humidifying fi lter unit from the tray.

Humidifying tray

Humidifying fi lter unit

Lift up slightly and pull out

Hold the outer 
periphery of 
the frame

•  Hold the base of the humidifying tray, lift up slightly 

and pull out.

•  Pull out the tray gently, because if there is any water 

inside, the water surface may ripple and it may spill out.

•  When carrying, hold the base of the humidifying tray.

Attaching the humidifying tray and 

humidifying fi lter unit

1. 

Attach the humidifying tray and humidifying 

fi lter unit.

1

  Attach the humidifying fi lter unit to the tray.

Fit axle into groove in 
humidifying tray

Axle

Humidifying fi lter

•  Attach the humidifying fi lter unit in the orientation 

shown in the illustration. 
If attached in the opposite orientation, it may become 
impossible to remove the humidifying tray, the humidifi cation 
performance may deteriorate, or abnormal noise may occur.

2

  Fully push in the humidifying tray to the main unit.

Attention

After installing the humidifying tray to the main unit, do not forcibly 
rotate the humidifying fi lter unit. Malfunction may result.

2. 

Put the water tank in. 

Page 12

Содержание MCK70YV

Страница 1: ...g Air Purifier Model Thank you for purchasing this humidifying air purifier Please read the operation manual carefully and follow it for correct use Please read the Safety Precautions section before u...

Страница 2: ...ters Replace 31 Streamer Unit 32 Dust Collection Filter Replace 33 When Not Using the Unit for a Prolonged Period 33 Operation When you want to let the unit decide the best operation mode 15 AUTO oper...

Страница 3: ...the power supply plug or cord is damaged it must be replaced by the manufacturer its service agent or a similar qualified person in order to avoid a hazard An electric shock short circuiting or fire m...

Страница 4: ...sounds or vibrations during operation The casing of the unit has become deformed or is abnormally hot There is a burnt smell Malfunction an electric shock smoke fire etc may result if the abnormality...

Страница 5: ...supply cord Fire an electric shock or injury may result When using the humidifier maintain the cleanliness of the water tank humidifying tray and humidifying filter unit at all times Replace the wate...

Страница 6: ...deformation may result On top of a thick carpet bed cover or mattress The unit may tilt causing water to spill or the water level sensor may fail to work correctly Places exposed to direct sunlight D...

Страница 7: ...is below Louvre Hand operated Water tank Humidifying filter unit Page 29 30 Humidifying tray Page 29 Air inlets Grip for carrying the unit Pre filter Filter frame Black Page 13 14 27 Streamer unit Ind...

Страница 8: ...dust PM2 5 sensor This is normal not a malfunction Dust PM2 5 sensor detection range Detectable matter house dust tobacco smoke pollen mite droppings and remains pet hairs diesel particulate matter S...

Страница 9: ...lug is inserted every time Insert the power supply plug when the air is clean odour free Odour sensor detection range Detectable matter tobacco odours cooking odours pet odours toilet smells waste sme...

Страница 10: ...e 20 HUM lamp orange Lamp will light up when the humidifying operation is active GOOD SLEEP MODE lamp green Lamp will light up when in GOOD SLEEP MODE Page 20 BRIGHTNESS button During operation each t...

Страница 11: ...the power ON or OFF AUTO operation lamp green Lights up during AUTO operation Page 15 HUM button Humidifying operation ON OFF and the humidification mode can be selected Page 17 The lamp turns off whe...

Страница 12: ...is not a defect Pointers for good positioning Choose a position from where airflow can reach all areas of the room Place on a stable surface If the unit is placed on an unstable surface vibrations fro...

Страница 13: ...ten the cap on the water tank If not done water leakage could result Water can be filled right up to the neck Tighten securely Note that even if tightened securely and completely the screw threads wil...

Страница 14: ...ing the tab in the centre remove the hooks 4 places on the left right from the holes in the unit 4 places on the left right Pre filter Holes 4 places left right Hooks Hooks 4 places left right 4 Remov...

Страница 15: ...om part fully behind the protrusions Dust collection filter The dust collection filter has a special orientation Check the symbol on the upper part of the filter before attaching Deodorising filter Pr...

Страница 16: ...ow Standard High Monitoring mode Blinking About AUTO operation The unit automatically switches between air purifying operation and humidifying operation based on the indoor temperature and humidity co...

Страница 17: ...leep hours As the deodorising capacity is reduced it is recommended that the FAN setting be set to Standard or above if odour needs to be quickly eliminated from a room Turbo The ambient air is quickl...

Страница 18: ...ng operation exclusively Attention Make sure that the humidifying filter unit is attached when using this operation Change the water in the humidifying tray and water tank everyday Be sure to use tap...

Страница 19: ...on in 10m area over 1 hour Assuming 1 cigarette was smoked immediately after the unit was turned on Power saving mode FAN setting switches automatically between Quiet and Low If the air is clean and t...

Страница 20: ...ated 100 90 80 70 60 50 40 30 0 30 25 20 15 10 Room conditions and target humidity Target humidity Room temperature C 60 50 40 70 CIRCULATOR When you want to circulate the air in the room The air in t...

Страница 21: ...ble for when you are sleeping or taking a nap etc The airflow rate is adjusted automatically between 3 levels Quiet Low and Standard The indicator lamp brightness is set to OFF Streamer discharge stop...

Страница 22: ...gh will blink for about 5 seconds and then the lamp corresponding to the current setting will light up Current setting HUM lamp Low HUM lamp High ON OFF Lit up OFF Lit up OFF 3 Press to change the out...

Страница 23: ...Current setting FAN lamp Quiet FAN lamp Standard Normal OFF Lit up Low Lit up OFF 3 Press to change the output settings Each press cycles between Normal and Low streamer output The MODE ANTI POLLEN la...

Страница 24: ...es between the FAN lamps allowing you to change the sensitivity To set sensitivity High Select the FAN lamp Turbo Turbo Standard Low High Normal Low The sensor is highly receptive The sensor is slight...

Страница 25: ...down for about 3 seconds with the power supply plug inserted and the unit turned off Each time is held down for about 3 seconds the setting switches between ON and OFF When the setting is changed to...

Страница 26: ...amp will light up or blink depending on the setting status 3 Press to change the setting Each press turns the ECONO MODE lamp ON or OFF The HUM lamp Low will remain lit up To turn Monitoring mode ON T...

Страница 27: ...26 Advanced Settings English This page is blank to make the next chapter easier for users to read as well as to satisfy typesetting constraints...

Страница 28: ...or holes are opened etc dust will pass through the filter and capacity for dust collection will be reduced Page 33 4 Deodorising Filter 5 Streamer Unit Wear gloves when working Dust from the deodoris...

Страница 29: ...n dirt on the exterior of the water tank becomes an issue Wipe Each season or when water scales white and brown are hard to remove Soak in citric acid or lemon juice About every 10 years Replace Wipe...

Страница 30: ...Sectional view Float Fill the tray with water and check that the float rises to the water surface After checking be sure to discard the water then attach the humidification tray to the unit Removing...

Страница 31: ...at a pharmacy drug store or super market Usage quantity 1 4 cup of lemon juice per 3 cups of water Bottled 100 lemon juice can be used Use only 100 lemon juice with no pulp strain juice if necessary...

Страница 32: ...ter Push frame hooks in direction of arrow Do not dispose of the frame Do not dispose of axle About the water scoop If the frame upper half is impacted the water scoop on the back side may detach Humi...

Страница 33: ...Grip Streamer unit Hold the centre of the grip and insert slowly and fully 8 Attach the front panel Page 14 1 Remove the power supply plug 2 Remove the front panel Page 13 3 Remove the streamer unit S...

Страница 34: ...cket and operate Dust Collection Filter Replace Replace about every 10 years About part replacement timing Replacement timing depends on usage patterns and the location of the unit Standard replacemen...

Страница 35: ...dust collection filter easily turns black A The blackening does not affect dust collection performance However it can be replaced if it is an issue Dust collection filter Q No steam is visible during...

Страница 36: ...er socket then remove the filter from the bag Finally re attach the filter and start operation again Are the front panel pre filter dust collection filter humidifying filter unit humidifying tray and...

Страница 37: ...er unit dirty A sound may be generated when there is a buildup of water scales on the humidifying tray or humidifying filter unit Clean these parts Page 29 30 Splashing sound during Humidifying operat...

Страница 38: ...was cleaned Did you clean it after unplugging the power supply plug Unplug the unit wait at least 5 seconds and then reinsert the power supply plug Is the streamer unit securely attached Insert the st...

Страница 39: ...oom Is the louvre closed Open the louvre Page 15 Is the pre filter or dust collection filter dirty Clean the pre filter replacement of the dust collection filter may also be necessary Page 27 The air...

Страница 40: ...hieved Are you using the unit in a room with an area larger than applicable Page 42 Is the target humidity set to Low or Standard Is the FAN setting set to Quiet or Low Set the humidification mode to...

Страница 41: ...rt is not attached unplug the unit and attach all the parts before turning the unit on again There is a burnt mark on the metal part of the streamer unit This is a mark left from the streamer discharg...

Страница 42: ...er made of polyester and polypropylene and the humidifying filters made of polyester Disposal requirements Units are marked with the following symbol This means that electrical and electronic products...

Страница 43: ...ater tank is empty Water tank volume L About 3 6 Power supply cord length m 2 Made in China These specification values are applicable to both 50Hz 220 240V and 60Hz 220 230V Even when the power is off...

Страница 44: ...bar code is a manufacturing code DAIKIN ISITMA VE SO UTMA S STEMLER SAN T C A G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 0...

Отзывы: