Daikin KRP067A41 Скачать руководство пользователя страница 1

Inside the indoor unit

This set

S602

S601

S403

S21

To central control 
device

Option:
KRP413AB1S
KRP928BB2S

PCB of indoor unit

Electrical 
wiring box

1P398933-1C

M15B230A

This set is an interface that connects a central control device to a room 
air conditioner and allows you to perform the following operations, or 
monitoring, in combination with the central control device using 
KRP413AB1S or KRP928BB2S (sold separately).

• 

Starting and stopping the air conditioner, and setting the mode and 

temperature, through the central control device or the wired remote controller. 
(64°F to 90°F (18°C to 32°C) in COOL operation, 57°F to 82°F (14°C to 28°C) 
in HEAT operation, none in FAN operation)

• 

Monitoring the operating conditions, occurrence of errors, and contents of 

errors of the air conditioner through the central control device or the wired 
remote controller.

• 

Restricting the operation with a wireless remote controller found near the air 

conditioner, such as starting and stopping operation, changing the mode, or 
setting the temperature, through the use of the central control device, coin 
timer, or card key.

• 

Zone control through the central control device.

• 

Restoring the operating conditions of the air conditioner to the previous 

conditions at the time of power recovery in case of power outage.

• 

Group control (i.e., the control of multiple indoor units through a single 

remote controller)

• 

Monitoring of the following items: Indoor temperature and operating 

conditions of thermo, compressor, indoor fan, electric heater, and humidifier

•  Control of the following items: Forced thermo OFF, filter sign display and 

reset, airflow direction, airflow rate setting, and air-conditioner charge 

management

• 

Energy-saving command, low-noise command, and demand command

This set does not support the following functions.

This set includes the following components. Please confirm them.

Component

Component

Installation

Manual

1

1

Quantity

Quantity

Main
component

Installation Position

Wiring Outline

 •  Do not install the air conditioner where gas leakage would 

be exposed to open flames. 

If the gas leaks and builds up around the unit, it may catch fire.

•  Touch a nearby metal object (doorknob, aluminium sash, 

etc.) to discharge static electricity from your body before 

touching this set.

(Static electricity from your body can damage this set.)

 •  Lay the cable separately from other power cables.

(Poor wiring may cause external electrical noise.)

 • Removal method

1) 

Place your fingers in the indentations on the main unit 

(one each on the left and right sides), and open the 
panel until it stops.

2) Continue to open the front panel further while sliding the 

panel to the left and pulling it toward yourself in order to 
disengage the rotating shaft on the left side. 
To disengage the rotating shaft on the right side, slide 
the panel to the right while pulling it toward yourself.

 • Installation method

Align the rotating shaft of the front panel with the grooves, 
and push all the way in. Then close slowly. 
Push both the sides and the center of the lower surface of 

the panel firmly.

 •  Installation method

1) 

Install the front grille and firmly engage the upper 

hooks (3 locations).

2) Insert 2 screws of the front grille.
3) 

Install the air filter then mount the front panel.

When there is no work space because the 

unit is close to ceiling 

>

Disengage the flap (horizontal blade), and pull the lower 

part of the front grille toward yourself to remove it.

If it is difficult to remove, place both hands under the 

center of the front grille, and while pushing up, pull it 
toward yourself.

 • Removal method

1) Remove front panel.
2) 

Remove the air filter.

3) Remove the screws (2) from the front grille.
4) 

Disengage 3 hooks (the location can be identified by

  mark) at the top of the grille.

Continued on back

Note:
Wires indicated by 
thick lines             
are not included 
with the set.

Removal and Installation of Front Panel 

Removal and Installation of Front Grille 

Installation Procedure

• 

Read these 

Safety Considerations

 carefully to ensure correct 

installation. 

•  This manual classifies the precautions into 

WARNING

 and 

CAUTION

Be sure to follow all the precautions below: they are all important for 
ensuring safety.

Remote Control PC-Board Set

<KRP067A41, KRP067A41E>

Installation Manual

Safety Considerations

Outline / Features

Components

WARNING : 

Failure to follow any of WARNING is likely to result 

in such grave consequences as death or serious 
injury.

CAUTION  : 

Failure to follow any of CAUTION may in some 
cases result in grave consequences.

WARNING

 •  Installation shall be left to the authorized dealer or another 

trained professional. 

Improper installation may cause water leakage, electrical 

shock, fire, or equipment damage.

 •  Be sure to use the supplied or exact specified installation parts.

Use of other parts may cause the unit to come to fall, water 

leakage, electrical shock, fire or equipment damage.

 •  Be sure to switch off the unit before touching any electrical parts.
 •  Be sure to install a ground fault circuit interrupter / earth 

leakage circuit breaker. 

Failure to install a ground fault circuit interrupter / earth 

leakage circuit breaker may result in electrical shock, fire or 

personal injury.

CAUTION

 •  After completing installation, test the unit to check for 

installation errors. Give the user adequate instructions 

concerning the use and cleaning of the unit according to the 

Operation Manual.

Be sure to wear protection gloves.

CAUTION

Opening Service Lid of Indoor Unit

The service lid is of removable type.

 • Opening method

1) Remove the single screw of the service lid.
2) Pull out the service lid frontward.

Electrical 
wiring box

Installation 

position 

of the set

Rotating shaft

Push the rotating shaft

of the front panel into

the groove.

1) Push up.

2) Pull toward yourself.



 mark area 

(3 locations)

Hook

Push

down.

Hook

Indentations on 

the main unit

1P398933-1C.indd   1

5/11/2016   12:05:16 PM

Содержание KRP067A41

Страница 1: ...stallation Manual 1 1 Quantity Quantity Main component Installation Position Wiring Outline Do not install the air conditioner where gas leakage would be exposed to open flames If the gas leaks and builds up around the unit it may catch fire Touch a nearby metal object doorknob aluminium sash etc to discharge static electricity from your body before touching this set Static electricity from your bod...

Страница 2: ...he front panel When there is no work space because the unit is close to ceiling Disengage the flap horizontal blade and pull the lower part of the front grille toward yourself to remove it If it is difficult to remove place both hands under the center of the front grille and while pushing up pull it toward yourself Removal method 1 Remove front panel 2 Remove the air filter 3 Remove the screws 2 from...

Страница 3: ...h wire 4 Remove the mounting screw of the electrical wiring box 1 screw Mounting screw of electrical wiring box The position of the ground earth wire may differ depending on the model Make sure that the mounting bracket of the thermistor will not fall off Thermistor Inter unit wire Ground Earth wire Green Yellow Ground Earth wire Green S200 S6 WARNING Be sure to turn OFF the power at the time of i...

Страница 4: ...e HA connector S21 white on the HA PCB this set 2 Route the HA connection cord as shown in Fig 2 Connecting HA PCB Fig 1 Connection points of the HA PCB Fig 2 Routing HA connection cord HA PCB HA connector S21 white Installing HA PCB on the electrical wiring box Electrical wiring box Back of the HA PCB Spacer S403 Insert the cord into the S403 connector HA connector S21 white HA PCB Electrical wir...