background image

intelligent Touch Manager

Model

DCM601B71

Installation Manual

3P291714-8H

Содержание intelligent Touch Manager DCM601B71

Страница 1: ...intelligent Touch Manager Model DCM601B71 Installation Manual 3P291714 8H...

Страница 2: ...installa tion If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct th...

Страница 3: ...uld result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practi...

Страница 4: ...d c Near machinery emitting electromagnetic waves Electromagnetic waves may disturb the operation of the control system and cause the unit to malfunction d Where flammable gas may leak where there is...

Страница 5: ...5 2 2 1 Terminal location and schematic connection diagram 15 2 2 2 Wiring specifications 17 2 2 3 Precautions for using multiple centralized controllers 17 2 3 Connecting a LAN cable 18 2 3 1 Termina...

Страница 6: ...g on power supply for intelligent Touch Manager and air conditioners 33 4 3 Setting up locale 34 4 4 Setting time zone 34 4 5 Setting current time and daylight saving time 35 4 6 Confirming air condit...

Страница 7: ...cluded If there is any missing or defective part contact your DAIKIN dealer where you purchased the product Accessories included with intelligent Touch Manager A B E D F C b 1 a 1 b 2 b 3 e 2 e 1 d 1...

Страница 8: ...nager English 1 2 Understanding external dimensions intelligent Touch Manager body 9 9 16 5 31 32 1 5 32 8 5 32 11 13 32 3 16 3 16 3 16 3 16 31 32 31 32 5 16 5 16 5 16 5 16 10 3 32 10 23 32 in Wall mo...

Страница 9: ...DCM601B71 intelligent Touch Manager 9 English Frame bracket 11 3 32 8 3 16 9 7 32 2 7 16 1 17 32 9 1 2 8 27 32 9 32 8 13 16 in Thickness 1 16 Angle bracket 9 29 32 8 13 16 4 13 32 8 5 16 1 1 8 25 32...

Страница 10: ...ired B DIII The communication line connection terminals for DIII NET which enables communications with DAIKIN s air conditioning equipment C LINE PHONE The port used when subscribing to the DAIKIN Air...

Страница 11: ...ly for retaining the current settings D DIII MASTER The switch for setting MASTER or SLAVE when there are multiple DIII NET centralized controllers such as intelligent Touch Manager E CPU ALIVE LED Gr...

Страница 12: ...connect to this port from the front direction if there is not enough space on the side 1 3 4 Wiring of cables To flush mount the intelligent Touch Manager to the wall you need to route in advance the...

Страница 13: ...eck that the installation environment meets the following conditions The ambient temperature 32 to 104 F The ambient humidity 85 RH or less without condensation The electromagnetic wave does not affec...

Страница 14: ...turn on the power supply before all wire connections are completed When there is an earth leakage breaker or a local switch installed on the circuit make sure that the circuit is securely interrupted...

Страница 15: ...r WARNING Be sure to perform the operation during power off conditions Not doing so may cause an electric shock The maximum length of adhered wiring of high current electrical line of power wires and...

Страница 16: ...N P N P N P N P N P A Outdoor unit B OUT OUT communication terminal C IN OUT communication terminal D Indoor unit E A maximum of 16 indoor units can be connected per remote controller group F A maximu...

Страница 17: ...61 ft or less When using a shielded wire the total wiring length is limited to 4921 ft or less 2 2 3 Precautions for using multiple centralized controllers The centralized controller refers to the equ...

Страница 18: ...ller Main 5 intelligent Touch Manager Sub iTM plus adaptor Sub 6 Central Remote Controller Sub 7 ON OFF Controller Main 8 ON OFF Controller Sub Priority Low Centralized controllers that cannot be conn...

Страница 19: ...ble cable standard 100Base TX or 10Base T Connector standard RJ 45 SERVICE LAN socket and LAN SW switch NOTE When you connect the intelligent Touch Man ager to the LAN temporarily during installation...

Страница 20: ...ith high current lines such as a power cable 2 4 1 Terminal location and schematic connection diagram Schematic drawing of I O module connection MONITOR RS 485 The number of contacts per node is up to...

Страница 21: ...eration during power off conditions Not doing so may cause an electric shock Do not clamp high current cables together with low current cables 2 5 1 Terminal location and schematic connection diagram...

Страница 22: ...rgency stop input is cleared When the manual reset is specified for the resetting method you need to clear the emergency stop using the intelligent Touch Manager 2 6 Connecting iTM plus adaptors If yo...

Страница 23: ...agram A intelligent Touch Manager B iTM plus adaptor C plus ADP IF intelligent Touch Manager D plus ADP IF iTM plus adaptor E iTM plus adaptor on which termination resistor must be enabled For details...

Страница 24: ...ver Power supply terminal diagram Open the power supply terminal cover by lifting upward A A Power supply terminal cover 2 7 2 Terminal location and schematic connection diagram Schematic power connec...

Страница 25: ...own power supply to the entire system must be installed Turning on off the earth leakage breaker turns on off the power supply to the intelligent Touch Manager When using an earth leakage breaker make...

Страница 26: ...e bracket and angle brackets Direct mounting to control enclosure Fix the intelligent Touch Manager directly to the control enclosure using screws only with no brackets Ways of installation Wall mount...

Страница 27: ...o fix the plate we recommend you to use ones closer to the edge in order to prevent wobbling Secure the round head wood screws at four points Wall mounting installation MONI TO R B A D C C C C NOTE Ho...

Страница 28: ...eck that there are all accessories listed in section 1 1 see the accessories included with intelligent Touch Manager C 3 2 2 Wall opening dimensions Use the following dimensional drawing to provide a...

Страница 29: ...d to the rear face of the intelligent Touch Manager through the cable hole provided at the bottom of the frame bracket Remove the terminal cover from the rear face then install the intelligent Touch M...

Страница 30: ...ing four screw holes around the monitor screen and the pan head screws NOTE When securing the intelligent Touch Manager in the frame bracket do not over tighten the pan head screws After tightening th...

Страница 31: ...ntrol enclosure bottom board C intelligent Touch Manager D 31 32 in min E Opening 3 3 3 Installation procedure 1 Remove the front panel of the intelligent Touch Manager referring to Removing front pan...

Страница 32: ...Touch Manager is directly mounted to the control enclosure you will be exposed to the power line connection terminals when opening the control enclosure door Touching electrical junctions by hand may...

Страница 33: ...inal position If the power supply is left off for a long period of time six months or more turn OFF the BACKUP switch 4 2 Turning on power supply for intelligent Touch Manager and air conditioners Tur...

Страница 34: ...nheit Select the temperature display unit Celsius or Fahrenheit Decimal point CSV separate Select the marks used as the decimal point and CSV separator For details refer to the User s Manual EM11A017...

Страница 35: ...ation results On the A C Auto Register screen the message Below connected A C units are found Do you want to register into Management Points Reboot after registering appears 1 Check that the number of...

Страница 36: ...as examples NOTE For how to set the address for the Ventilator Heat Reclaim Ventilator or different adapt ers such as a universal adapter refer to the manuals supplied with those devices 4 7 1 Names o...

Страница 37: ...oller display Using the Temperature Setting buttons change the value shown in the parameter num ber display area to 00 In the address display area the current address setting is displayed This area wi...

Страница 38: ...select the address you want to set Step 4 SETTING GROUP 5 Press the SCHEDULE button to make the GROUP indicator stay lit The DIII NET address has been set Step 5 SETTING GROUP 6 Press the Inspection...

Страница 39: ...Fan ON Setting Service Settings Error History Outdoor Unit Status Indoor Unit Status 2 3 NOTE The Group Address menu is not displayed when the intelligent Touch Manager is not powered on Power on the...

Страница 40: ...elease Group Address Group 7 Press the Cancel button three times You are now brought back to the screen shown in Step 7 2 Step 7 1 Gr Addr Set 1 03 Release Group Address Group Step 7 2 Cool Room Thu 8...

Страница 41: ...st format 1 List Icon 1 3 3 2 1 Touch the List button 2 The screen changes to the list view where selecting Indoor in the Type combo box causes the name operation mode setpoint and fan speed of all ar...

Страница 42: ...g an area or management point A On 1 2 2 1 Select the area or management point you want to start or stop 2 Select Start or Stop in the On Off buttons When operation is started the icon color changes t...

Страница 43: ......

Страница 44: ...3P291714 8H EM21A029A 2205 HT...