SYSTEM

Air Conditioners

INSTALLATION MANUAL

CAREFULLY READ THESE INSTRUCTIONS BEFORE INSTALLATION.

KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
VEUILLEZ LIRE ATTENTIVEMENT CES INSTRUCTIONS AVANT L'INSTALLATION.

CONSERVEZ CE MANUEL EN LIEU SÛR POUR POUVOIR VOUS Y REPORTER 

ULTÉRIEUREMENT.
LEA DETENIDAMENTE ESTAS INSTRUCCIONES ANTES DE LA INSTALACIÓN.

CONSERVE ESTE MANUAL PARA POSIBLES CONSULTAS FUTURAS.
PRIMA DELL'INSTALLAZIONE, LEGGERE ATTENTAMENTE LE PRESENTI ISTRUZIONI.

CONSERVARE IL PRESENTE MANUALE IN UN LUOGO FACILMENTE ACCESSIBILE PER 

RIFERIMENTO FUTURO.
LEES DEZE INSTRUCTIES ZOGVULDIG DOOR VOORDAT MET DE INSTALLATIE WORDT 

BEGONNEN.

BEWAAR DEZE HANDLEIDING VOOR TOEKOMSTIG GEBRUIK OP EEN GESCHIKTE 

PLAATS ONDER HANDBEREIK.
LEIA ATENTAMENTE ESTAS INSTRUÇÕES ANTES DA INSTALAÇÃO.

MANTENHA ESTE MANUAL NUM LOCAL DE FÁCIL ACESSO PARA CONSULTA.

00_CV_3P366851-14C.fm  Page 1  Wednesday, September 2, 2015  5:01 PM

Содержание FXAQ20PVE

Страница 1: ...R POUVOIR VOUS Y REPORTER ULT RIEUREMENT LEA DETENIDAMENTE ESTAS INSTRUCCIONES ANTES DE LA INSTALACI N CONSERVE ESTE MANUAL PARA POSIBLES CONSULTAS FUTURAS PRIMA DELL INSTALLAZIONE LEGGERE ATTENTAMENT...

Страница 2: ...us situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices After the installation is completed test the air conditioner and check if...

Страница 3: ...t in place overheat of the terminals electric shocks or a fire may be caused If refrigerant gas leaks during installation work ventilate the area immediately Toxic gas may be produced if refrigerant g...

Страница 4: ...n to the place of purchase or a qualified serviceman Improper installation could lead to leaks and in worse cases electric shock of fire Use only parts provided with the unit or parts satisfying requi...

Страница 5: ...nsufficient cooling Is the unit fully insulated Condensate water may drip Does drainage flow smoothly Condensate water may drip Does the power supply voltage correspond to that shown on the name plate...

Страница 6: ...to the installation manual of the outdoor unit Install the indoor and outdoor units power cable and transmission wiring at least 1 m from TVs and radios to prevent distorted pictures and static Depen...

Страница 7: ...PIPING WORK 2 Remove the installation panel 1 from the unit and attach to the wall The installation panel is temporarily attached to the unit with screw In case of 20 32 type Refer to Fig 3 a Check th...

Страница 8: ...he front grille as described below when securing the indoor unit with screws or when attaching Optional Accessories wireless remote controller adapter PC board etc 1 Remove the front panel 2 Remove th...

Страница 9: ...pply wiring transmission wiring earth wiring and remote controller wiring through the wiring guide in through the back of the indoor unit and to the front Drain plug Insulating tube Fig 8 Do not place...

Страница 10: ...unit Remove the front grille Refer to Fig 7 Secure the indoor unit to the installation panel 1 with the securing screws 6 Refer to Fig 11 5 REFRIGERANT PIPING WORK For the outdoor unit refrigerant pi...

Страница 11: ...d in the outdoor unit When connecting the pipings to the air conditioner make sure to use a spanner and a torque wrench as shown in Fig 12 For the dimension of flared part and the tightening torque re...

Страница 12: ...ontains fluorine it will damage the refrigerant oil Before brazing local refrigerant piping nitrogen gas shall be blown through the piping to expel air from the piping If your brazing is done without...

Страница 13: ...o insulate the extended section of the drain hose which is indoors Refer to Fig 17 Make sure the diameter of the piping is the same as the piping hard vinyl chloride nominal diameter 13mm or bigger In...

Страница 14: ...ion manual attached to the remote controller All wiring must be performed by an authorized electrician This system consists of multiple indoor units Mark each indoor unit as unit A unit B and be sure...

Страница 15: ...TO CONNECT WIRINGS Methods of wiring power supply units and connecting remote controller wiring Power supply wiring and earth wire Unscrew and remove the service cover Connect the power supply wiring...

Страница 16: ...al heating may occur if the wirings are not tightened securely Use the required wirings connect them securely and fix these wirings securely so that external force may not apply to the terminals Use a...

Страница 17: ...pen the control box cover Make sure the cover closes tight Incomplete connections could result in overheating and in worse case electric shock or fire Round crimp style terminal Attach insulation slee...

Страница 18: ...rical noise external static could cause mistaken operation or breakage Use only specified wire and tightly connect wires to terminals Be careful wires do not place external stress on terminals Keep wi...

Страница 19: ...F1 F2 Control box LN P1 P2 P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 P1 P2 P1 P2 L N Outdoor unit No 2 System Indoor unit A Indoor unit B Indoor unit C Most dow...

Страница 20: ...tside to terminals T1 and T2 of the terminal block 6P for remote controller 2 Actuation The following table explains FORCED OFF and ON OFF OPERATIONS in response to Input A 3 How to select FORCED OFF...

Страница 21: ...ter contamination light Table 4 9 2 SETTING AIR FLOWRATE INCREASE MODE It is possible to raise set airflow HIGH and LOW from the field Change the SECOND CODE NO as shown in Table 5 to suit your needs...

Страница 22: ...rk is completed if the interior work has not been finished at the end of the test run If the air conditioner is operated substances discharged from the paint adhesive etc can contaminate the indoor un...