background image

MODELS

Wall-mounted type

FXAQ07MVJU
FXAQ09MVJU
FXAQ12MVJU
FXAQ18MVJU
FXAQ24MVJU

INSTALLATION MANUAL

Read these instructions carefully before installation.
Keep this manual in a handy place for future reference.
This manual should be left with the equipment owner.

SYSTEM Inverter Air Conditioners

00_CV_3PN07521-1.fm  Page 1  Monday, June 19, 2006  2:30 PM

Содержание FXAQ07MVJU

Страница 1: ...4MVJU INSTALLATION MANUAL Read these instructions carefully before installation Keep this manual in a handy place for future reference This manual should be left with the equipment owner SYSTEM Invert...

Страница 2: ...n how to operate the unit and keep it maintained Also inform customers that they should store this installation manual along with the operation manual for future reference This air conditioner comes u...

Страница 3: ...ater leakage electric shocks or fire Be sure to use only the specified accessories and parts for installation work Failure to use the specified parts may result in water leakage electric shocks fire o...

Страница 4: ...electrical parts can cause malfunctions smoke or fire Please instruct the customer to keep the area around the unit clean NOTE Install the indoor and outdoor units power supply wiring and connecting...

Страница 5: ...r is suitable for installation in a commercial and light industrial environment If installed as a household appliance it could cause electromagnetic interference WARNING Entrust installation to the pl...

Страница 6: ...s the air passage Where condensate can be properly drained Items to be checked If not properly done what is likely to occur Check Are the indoor and outdoor unit fixed firmly The units may drop vibrat...

Страница 7: ...fore proceeding with the installation Also reinforce the place to prevent vibration and noise before installing The installation pitch can be found on the paper pattern for installation 3 so refer to...

Страница 8: ...at least a 3 1 2 gap between the ceiling and the main unit b Temporarily attach the installation panel 1 at the temporary securing position on the paper pattern for installation 3 and use a level to m...

Страница 9: ...and back left piping Remove the front grill Refer to Fig 7 How to remove the front grill Remove the front grill as described below when securing the indoor unit with screws or when attaching Optional...

Страница 10: ...e refrigerant piping to the wall 7 Pass power supply wiring and ground wiring threaded through conduit For connecting the con duit to the unit see 8 1 HOW TO CONNECT WIRINGS and remote controller wiri...

Страница 11: ...p to approximately 250 F so use insulation which is sufficiently resistant Also in cases where the temperature and humidity of the refrigerant piping sections might exceed 86 F or RH80 reinforce the r...

Страница 12: ...nt to leak Use the flare nut included with the unit Refer to Table 1 for tightening torque Table 1 Not recommended but in case of emergency You must use a torque wrench but if you are obliged to insta...

Страница 13: ...ould be set to 2 9 psi with a pressure reducing valve if brazing while inserting nitrogen into the piping Refer to Fig 14 After checking for gas leaks be sure to insulate the pipe connections using th...

Страница 14: ...eter of drain piping which adapts to the capacity of the unit connected 2 Make sure the drain works properly After drain work is complete perform a drain check by opening the front panel removing the...

Страница 15: ...it for the size of power supply wiring connected to the outdoor unit the capacity of the circuit breaker and switch and wiring instructions Be sure to ground the air conditioner DANGER Do not ground u...

Страница 16: ...22 Transmission wiring and remote controller wiring Unscrew and remove the service lid Thread the remote controller wiring and transmission wiring through the included insulating tube long 7 and secur...

Страница 17: ...oller wiring and transmission wiring between the units and other electrical wir ing do not pass through the same locations outside the unit separating them by at least 5 otherwise elec trical noise ex...

Страница 18: ...e terminal screws 3 Do not connect wires of different gauge to the same ground terminal Looseness in the connection may lessen protection 4 Keep transmission wiring at least 5 away from power supply w...

Страница 19: ...D OUT D F1 F2 F1 F2 Control box P1 P2 P1 P2 F1 F2 T1 T2 P1 P2 F1 F2 T1 T2 P1 P2 F1 F2 T1 T2 P1 P2 F1 F2 T1 T2 P1 P2 P1 P2 Outdoor unit No 2 System Indoor unit A Indoor unit B Indoor unit C Most downst...

Страница 20: ...other remote controller set to M Refer to Fig 29 Wiring Method See 7 ELECTRIC WIRING WORK 3 Remove the service lid 4 Add remote control 2 slave to the terminal block 6P for remote controller P1 P2 in...

Страница 21: ...NO and SECOND CODE NO Refer to the installation manual attached to the remote controller The Field Settings included with the remote controller lists the order of the settings and method of oper ation...

Страница 22: ...onding trouble is provided in the installation manual of the outdoor unit If any of the items in Table 5 are displayed there may be a problem with the wiring or power so check the wiring again Table 5...

Страница 23: ...0609 HT 3PN07521 1 EM04A013B 00_CV_3PN07521 1 fm Page 2 Monday June 19 2006 2 30 PM...