DAIKIN ROOM AIR CONDITIONER

Operation Manual

R410A

          

R32

FVXS25FV1B    FVXM25FV1B
FVXS35FV1B    FVXM35FV1B
FVXS50FV1B    FVXM50FV1B

3PEN477071-1A.book  Page 1  Thursday, March 30, 2017  1:28 PM

Содержание FVXM25FV1B

Страница 1: ...DAIKIN ROOM AIR CONDITIONER Operation Manual R410A R32 FVXS25FV1B FVXM25FV1B FVXS35FV1B FVXM35FV1B FVXS50FV1B FVXM50FV1B 3PEN477071 1A book Page 1 Thursday March 30 2017 1 28 PM...

Страница 2: ...irection 14 POWERFUL Operation 16 OUTDOOR UNIT QUIET Operation 17 ECONO Operation 18 TIMER Operation 19 WEEKLY TIMER Operation 21 Note for Multi System 26 CARE Care and Cleaning 28 TROUBLE SHOOTING Tr...

Страница 3: ...to wipe the unit It could cause cracking electric shocks or fire only for R32 refrigerant Do not use refrigerant other than the one indicated on the outdoor unit R410A R32 when installing moving or r...

Страница 4: ...us resulting in injury product malfunctioning or product damage Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units Under certain conditions condensation...

Страница 5: ...ated if equipment such as a burner is used together with the air conditioner Before cleaning be sure to stop unit operation turn off the circuit breaker or remove the power cord Otherwise an electric...

Страница 6: ...rigerant The drain from the outdoor unit must be discharged to a place of good drainage For installation choose a place as described below A place solid enough to bear the weight of the unit which doe...

Страница 7: ...nly This setting automatically decides a blow pattern depending on mode and conditions The unit is shipped from the factory with this setting This setting is recommended Before opening the front panel...

Страница 8: ...2 Signal receiver It receives signals from the remote controller When the unit receives a signal you will hear a short beep Operation start beep beep Settings changed beep Operation stop beeeeep 13 Ai...

Страница 9: ...lector button It selects the operation mode AUTO DRY COOL HEAT FAN page 12 8 QUIET button OUTDOOR UNIT QUIET operation page 17 9 ECONO button ECONO operation page 18 10 SWING button Adjusting the Airf...

Страница 10: ...system is not used for a long time take the batteries out The batteries will last for approximately one year If the remote controller display begins to fade and the degradation of reception performanc...

Страница 11: ...rn the breaker ON Turning ON the breaker closes the flap This is a normal procedure Checks on Remote Controller Settings This remote controller is common to the heat pump model and cooling only model...

Страница 12: ...may cause a safety device to disable the system A safety device may work to stop the operation In multi system it may work to stop the operation of the outdoor unit only Condensation may occur on the...

Страница 13: ...in sequence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION lamp goes off To change the temperature setting 4 Pr...

Страница 14: ...lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting operation hot air does not flow out of indoor unit Note on COOL operation...

Страница 15: ...s Hold the knob and move the louver You will find a knob on the left side and the right side blades Notes on flap and louvers angle Unless SWING is selected you should set the flap at a near horizonta...

Страница 16: ...passed since turning on the air conditioner So that air does not come into direct contact with people air is blown upper air outlet room tem perature is equalized At start of operation or other times...

Страница 17: ...tion of whichever button is pressed last POWERFUL Operation can only be set when the unit is running Pressing the operation stop button causes the settings to be canceled and the disappears from the L...

Страница 18: ...ll operated indoor units However if using priority room setting see Note for Multi System page 26 This function is available in COOL HEAT and AUTO modes This is not available in FAN and DRY mode POWER...

Страница 19: ...ONO Operation can only be set when the unit is running Pressing the operation stop button causes the settings to be canceled and the disappears from the LCD ECONO operation is a function which enables...

Страница 20: ...idly 3 Press OFF TIMER button again The TIMER lamp lights up To cancel the OFF TIMER Operation 4 Press CANCEL button The TIMER lamp goes off NOTE When TIMER is set the present time is not displayed On...

Страница 21: ...ting rapidly 3 Press ON TIMER button again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for co...

Страница 22: ...of ON ON ON ON settings for example makes it possible to schedule operating mode and set temperature changes Furthermore by using OFF OFF OFF OFF settings only the turn OFF time of each day can be set...

Страница 23: ...CT button changes or setting in sequence In case the reservation has already been set selecting blank deletes the reservation Go to STEP 9 if blank is selected 5 Press NEXT button The ON OFF TIMER mod...

Страница 24: ...operation Do not forget to set the clock on the remote control first The day of the week ON OFF TIMER mode time and set temperature only for ON TIMER mode can be set with WEEKLY TIMER Other settings...

Страница 25: ...days of the week repeat STEP 4 and STEP 5 6 Press button to complete the setting is displayed on the LCD and WEEKLY TIMER operation is activated NOTE Copy mode COPY MODE The entire reservation of the...

Страница 26: ...WEEKLY button again If a reservation deactivated with WEEKLY button is activated once again the last reservation mode will be used To delete reservations Refer to page 22 When selecting desired mode...

Страница 27: ...r retailer or dealer for assistance NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent annoyance to neighbors The NIGHT QUIET Mode is activated whe...

Страница 28: ...oom A enters POWERFUL operation operation capacity will be concentrated in Room A In such a case the cooling heating efficiency of the units in Rooms B C and D may be slightly reduced 3 Priority when...

Страница 29: ...ht inner side of the front grille Close the panel slowly CAUTION Units Don t touch the metal parts of the indoor unit If you touch those parts this may cause an injury When removing or attaching the f...

Страница 30: ...ned with lukewarm water then dry them up in the shade It is recommended to clean the air filters every 2 weeks Titanium Apatite Deodorizing Filter The Titanium Apatite Deodorizing Filter can be renewe...

Страница 31: ...Deodorizing Filter contact to the service shop there you bought the air conditioner Dispose of the old filter as flammable waste Check that the base stand and other fittings of the outdoor unit are n...

Страница 32: ...p flashing after the above steps there is no malfunction page 26 An abnormal functioning happens during operation The air conditioner may malfunction with lightning or radio waves Turn the breaker OFF...

Страница 33: ...ler When there is no beeping sound then there is no refrigerant leak or it is still doing detection If there is no leak it will return to the previous mode of operation automatically after a few minut...

Страница 34: ...t odour This happens when smells of the room furniture or cigarettes are absorbed into the unit and discharged with the airflow If this happens we recommend you to have the indoor unit washed by a tec...

Страница 35: ...ature is reached the airflow rate is reduced or operation stopped in order to avoid generating cool airflow during heating and in order to keep the humidity from rising during cooling Operation will r...

Страница 36: ...of the air conditioner may get foul after several seasons of use result ing in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user...

Страница 37: ...ON AIR TEMPERATURE SENSOR CH ABNORMALITY OF REFRIGERANT LEAKAGE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTO...

Страница 38: ...3PEN477071 1A book Page 1 Thursday March 30 2017 1 28 PM...