Removal Procedure
4.6
Removal of Four-Way Valve
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Pull out the electronic
expansion valve coil.
2
Remove the terminal
cover.
Electronic
expansion
valve coil
(R7233)
Terminal cover
(R7234)