Indoor Unit
SiUS091133
13
Printed Circuit Board Connector Wiring Diagram
1. Indoor Unit
1.1
FTXS09/12LVJU
Connectors and
Other Parts
PCB (1): Control PCB
PCB (2): Signal Receiver PCB
PCB (3): Display PCB
PCB (4): INTELLIGENT EYE Sensor PCB
1) S1
Connector for DC fan motor
2) S21
Connector for centralized control (HA)
3) S25
Connector for INTELLIGENT EYE sensor PCB
4) S32
Indoor heat exchanger thermistor
5) S41
Connector for swing motors
6) S46
Connector for display PCB
7) S47
Connector for signal receiver PCB
8) H1, H2, H3, FG
Connector for terminal board
9) JA
Address setting jumper
10) JB
Fan speed setting when compressor stops for thermostat OFF
JC
Power failure recovery function (auto-restart)
11) LED A
LED for service monitor (green)
12) FU1 (F1U)
Fuse (3.15 A, 250 V)
13) V1
Varistor
1) S48
Connector for control PCB
1) S49
Connector for control PCB
2) SW1
Forced cooling operation [ON/OFF] button
3) LED1 (H1P)
LED for operation (green)
4) LED2 (H2P)
LED for timer (yellow)
5) LED3 (H3P)
LED for INTELLIGENT EYE (green)
6) RTH1 (R1T)
Room temperature thermistor
1) S26
Connector for control PCB
Содержание FTXS30LVJU
Страница 8: ...SiUS091133 Table of Contents vii...
Страница 11: ...SiUS091133 1 List of Functions Part 1 List of Functions 1 Functions 2 1 1 FTXS Series 2 1 2 FDXS Series 4...
Страница 15: ...SiUS091133 5 Specifications Part 2 Specifications 1 Specifications 6 1 1 FTXS Series 6 1 2 FDXS Series 11...
Страница 164: ...SiUS091133 Check Service Diagnosis 154 15 18 class 24 30 36 class Power module R16697 R16073 Power module...
Страница 259: ...Indoor Unit FTXS30 36LVJU SiUS091133 249 Removal Procedure 6 Disconnect the connector Step Procedure Points R9558...
Страница 413: ...Wiring Diagrams SiUS091133 403 Appendix...