Removal Procedure
1. Indoor Unit: FTXS09/12LVJU
1.1
Removal of Air Filters
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Appearance features
Warning
Dangerous: High voltage
A high voltage is applied to all
the electric circuits of this
product including thermistors.
When the signal receiver
catches a signal from the
remote controller, the receiving
tone sounds and the operation
lamp blinks immediately to
confirm the signal reception.
When the [ON/OFF] button is
kept pressed for 5 seconds, the
forced cooling operation is
performed for about 15 minutes.
2. Remove the air filters.
1
Open the front panel to
the position where it
stops.
2
Slightly push up the
center knob of the air
filter and release the
hooks.
The air filter is not marked for
difference between the right and
left sides.
The air filter can be set easily by
inserting it along the guides.
Insert the air filter with the
"FRONT" mark faced up.
Be sure to insert the hooks (at 2
lower positions) when
reassembling the air filter.
3
Pull out the air filter
downward and remove
it.
(R7900)
(R7901)
Signal receiver
Operation lamp
TIMER lamp
[ON/OFF] button
Room temperature thermistor
INTELLIGENT
EYE sensor
INTELLIGENT
EYE lamp
(R7902)
Front panel
(R7903)
Air filter
Содержание FTXS30LVJU
Страница 8: ...SiUS091133 Table of Contents vii...
Страница 11: ...SiUS091133 1 List of Functions Part 1 List of Functions 1 Functions 2 1 1 FTXS Series 2 1 2 FDXS Series 4...
Страница 15: ...SiUS091133 5 Specifications Part 2 Specifications 1 Specifications 6 1 1 FTXS Series 6 1 2 FDXS Series 11...
Страница 164: ...SiUS091133 Check Service Diagnosis 154 15 18 class 24 30 36 class Power module R16697 R16073 Power module...
Страница 259: ...Indoor Unit FTXS30 36LVJU SiUS091133 249 Removal Procedure 6 Disconnect the connector Step Procedure Points R9558...
Страница 413: ...Wiring Diagrams SiUS091133 403 Appendix...