manualshive.com logo in svg
background image

User Reference Guide 

Daikin room air conditioners

FTXP20M5V1B9
FTXP25M5V1B9
FTXP35M5V1B9

Содержание FTXP20M5V1B9

Страница 1: ...User Reference Guide Daikin room air conditioners FTXP20M5V1B9 FTXP25M5V1B9 FTXP35M5V1B9...

Страница 2: ...t airflow operation 23 5 6 1 To start stop Comfort airflow operation 23 5 7 Powerful operation 23 5 7 1 To start stop Powerful operation 24 5 8 Econo operation 25 5 8 1 To start stop Econo operation 2...

Страница 3: ...D520466 7C 2020 03 8 1 7 Symptom White mist comes out of a unit Indoor unit 40 8 1 8 Symptom The units can give off odours 40 8 1 9 Symptom The outdoor fan rotates while the air conditioner is not in...

Страница 4: ...1 Meaning of warnings and symbols DANGER Indicates a situation that results in death or serious injury DANGER RISK OF ELECTROCUTION Indicates a situation that could result in electrocution DANGER RISK...

Страница 5: ...icates a table title or a reference to it Example 1 3 Table title means Table 3 in chapter 1 1 2 For the user WARNING If you are NOT sure how to operate the unit contact your installer WARNING This ap...

Страница 6: ...lized treatment facility for reuse recycling and recovery By ensuring this product is disposed of correctly you will help to prevent potential negative consequences for the environment and human healt...

Страница 7: ...Operation manual Quick guide for basic usage Format Paper in the box of the indoor unit User reference guide Detailed step by step instructions and background information for basic and advanced usage...

Страница 8: ...onditioners 4D520466 7C 2020 03 Chapter Description Energy saving and optimum operation How to save energy Maintenance and service How to maintain and service the unit Troubleshooting What to do in ca...

Страница 9: ...ION The sound pressure level is less than 70 dBA WARNING Do not modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation may cause an electric shock or...

Страница 10: ...n If the user interface is missing you can use the ON OFF button on the indoor unit to start stop operation When operation is started using this button the following settings are used Operation mode A...

Страница 11: ...t wet 3 2 1 Components User interface b l k c d e f j i h g a a Signal receiver b OFF button c Fan setting button d Econo operation button e Swing buttons f Timer setting buttons ON OFF cancel g Power...

Страница 12: ...3 2 2 Status User interface LCD Icon Description Operation mode Automatic Operation mode Drying Operation mode Heating Operation mode Cooling Operation mode Fan only Powerful operation is active Econ...

Страница 13: ...ion mode Cooling Operation mode Fan only Powerful operation is active Econo operation is active Operation is active The indoor unit receives a signal from the user interface Current temperature settin...

Страница 14: ...ace a a Signal receiver a a Signal receiver 1 Aim the signal transmitter at the signal receiver on the indoor unit maximum distance for communication is 7 m Result When the indoor unit receives a sign...

Страница 15: ...operation usually consist of the following stages Inserting the batteries in the user interface Fixing the user interface to the wall Turning on the power supply 4 2 To insert the batteries The batter...

Страница 16: ...supply c User interface holder 1 Choose a place where the signals reach the unit 2 Attach the holder with screws to the wall or a similar location 3 Hang the user interface on the user interface holde...

Страница 17: ...utside its operation range b Condensation and water dripping might occur if the unit runs outside its operation range 5 2 When to use which feature You can use the following table to determine which f...

Страница 18: ...r fixed position Airflow rate To adjust the amount of air blown into the room To run more quietly Advanced features Econo To use the system when you are also using other power consuming appliances To...

Страница 19: ...g operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting operation to remove the frost During defrosting operati...

Страница 20: ...peration Fan only operation 6 Press or on the button one or more times to set the temperature You CANNOT adjust the temperature in drying or fan only operation mode Cooling operation Heating operation...

Страница 21: ...ill break Be careful when adjusting the louvers Inside the air outlet a fan is rotating at high speed Note The movable range of the flap varies according to the operation mode The flap will stop at th...

Страница 22: ...n 5 5 1 To adjust vertical airflow direction 1 Press Result appears on the LCD The flaps horizontal blades will begin to swing 2 To use fixed position press when the flaps reach the desired position R...

Страница 23: ...e Heating operation mode INFORMATION Powerful and Comfort airflow operation CANNOT be used at the same time The last selected function takes priority If the vertical automatic swing is selected Comfor...

Страница 24: ...ration will NOT increase the capacity of the unit if it already operates at maximum capacity 5 7 1 To start stop Powerful operation 1 Press to start Result is displayed on the LCD Powerful operation r...

Страница 25: ...tion will NOT further reduce power consumption 5 8 1 To start stop Econo operation 1 Press to start Result is displayed on the LCD 2 Press to stop Result disappears from the LCD a A B b c d A Running...

Страница 26: ...If is set when the unit is operating operation will stop after 5 hours 5 To cancel the setting press Result and the time setting disappear from the LCD and the timer lamp goes off INFORMATION Night s...

Страница 27: ...e setting advances by 1 hour The timer can be set between 1 to 12 hours Example If is set when the unit is NOT operating operation will start after 2 hours 5 To cancel the setting press Result and the...

Страница 28: ...ains or blinds Make sure the area is well ventilated Do NOT block any ventilation openings Ventilate often Extended use requires special attention to ventilation Keep doors and windows closed If the d...

Страница 29: ...imum operation User Reference Guide 29 FTXP20 35M5V1B9 Daikin room air conditioners 4D520466 7C 2020 03 Operate the system within the recommended temperature range 26 28 C for cooling and 20 24 C for...

Страница 30: ...ter or a cooker this may result in fire or the formation of a harmful gas Turn off any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do NOT use the...

Страница 31: ...door unit and user interface NOTICE Do NOT use gasoline benzene thinner polishing powder or liquid insecticide Possible consequence Discoloration and deformation Do NOT use water or air of 40 C or hig...

Страница 32: ...er CANNOT deodorize the air CANNOT clean the air poor heating cooling causes odour 7 5 To open the front panel 1 Hold the front panel by the panel tabs on both sides and open it 7 6 To clean the air f...

Страница 33: ...water or clean them with a vacuum cleaner 5 Soak in lukewarm water for about 10 to 15 minutes 6 Install all filters back in their original positions INFORMATION If the dust does NOT come off easily wa...

Страница 34: ...er particle filter Ag ion filter INFORMATION Clean the filter with water every 6 months 1 Remove the titanium apatite deodorizing and silver particle filters from the tabs a Tabs 2 Remove the dust fro...

Страница 35: ...hours to dry the inside of the unit 1 Press and select fan only operation 2 Press to start operation 3 Set the mode to fan only by pressing button to dry the inside of the unit 4 After operation stops...

Страница 36: ...er the operation lamp flashes and the malfunction code appears Notify your installer and report the malfunction code If the system does NOT operate properly except for the above mentioned cases and no...

Страница 37: ...the air filters See 7 Maintenance and service 430 Check for open doors or windows Close doors and windows to prevent wind from coming in Check if the unit operates in Econo operation Refer to 5 8 Eco...

Страница 38: ...rection setting is appropriate Refer to 5 5 Airflow direction 421 Check if the air inlet or outlet of the outdoor or indoor unit is NOT blocked by obstacles Remove any obstacles and make sure the air...

Страница 39: ...oms are NOT system malfunctions 8 1 1 Symptom A sound like water flowing is heard This sound is caused by the refrigerant flowing in the unit This sound may be generated when water is flowing away fro...

Страница 40: ...h the outdoor fan starts to rotate for system protection 8 2 Solving problems based on error codes If the unit runs into a problem the user interface displays an error code It is important to understa...

Страница 41: ...re thermistor abnormality Outdoor unit Error code Description 4 way valve abnormality Outdoor unit PCB abnormality Overload activation compressor overload Compressor lock DC fan lock Input power overc...

Страница 42: ...0466 7C 2020 03 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units M...

Страница 43: ...ain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application explaini...

Страница 44: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 4D520466 7C 2020 03 Copyright 20...

Отзывы: