3.7.2 Repair procedures
To correct the wiring from the main power supply terminal to the main PCB
ARXP20~35N + RXP20~35N units
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
1
Remove the required plate work, see
111].
2
Make sure that all wires are firmly and correctly connected, see
159].
3
Check the continuity of all wires.
4
Replace any damaged or broken wires.
Is the problem solved?
Action
Yes
No further actions required.
No
84] of the PCB and
continue with the next procedure.
To remove the main PCB
ARXP-L + ARXP-M + RXP-L + RXP-M + RXP50~71N units
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Disconnect all connectors from the main PCB.
2
Disconnect the power supply wires from the main power supply terminal
X1M.
d
d
e
e
d
a
a
b
c
a
Power supply wiring
b
Red wire
c
Ground wire
d
Screw
e
PCB support
3
Disconnect the red wire from the terminal X1M.
4
Remove the ferrite core (for power supply wiring) from the swich box (unplug
fixation plug).