SiUS042113E
Main Functions
Part 4 Functions and Control
27
1.4 COMFORT AIRFLOW Operation
Outline
New flap structure is developed with technology Coanda. In cooling operation, ceiling airflow
provides cool air upward along the ceiling as far as entire the room. In heating operation, draftless
airflow directs warm air straight downward to your feet.
Apply new airflow system, providing a comfortable cooling and heating space without draft
feeling and spreading comfort airflow with large air volume in low velocity with double airflow
technology to disseminate a wide of airflow in low velocity even with the large air volume.
Wind reaches far
Reaching distance 16.4 ft (5 m) (for 09/12 class), 32.8 ft (10 m) (for 18/24 class)
The comfort mode is set during cooling. Measure the distance that can secure a wind speed of
0.4 m/s or more at a position of 1.18 inch (30 mm) from the ceiling.
R4003805
Reaching distance 9.84 ft (3 m) (for all class)
The comfort mode is set during heating. Measure the distance that can secure a wind speed of
0.3 m/s or less at a position of 3.28 ft (1 m) from the floor.
R4003809
Ceiling airflow (Cooling)
16.4 ft (5 m) (for 09/12 class)
32.8 ft (10 m) (for 18/24 class)
1.18 inch (30 mm)
Wind speed 0.4 m/s or more
Draftless airflow (Heating)
Wind speed 0.3 m/s or less
3.28 ft (1 m)
*Floor temperature sensor is not mounted on.
30°
9.84 ft (3 m)
Содержание FTXM-V Series
Страница 13: ...SiUS042113E Part 1 General Information 9 1 Applicable Models 10 2 Functions 11 Part 1 General Information...
Страница 16: ...SiUS042113E 12 Part 2 Specifications 1 Specifications 13 Part 2 Specifications...
Страница 96: ...Troubleshooting SiUS042113E 92 Part 6 Service Diagnosis Reference Check No 01 Refer to P 134...
Страница 147: ...SiUS042113E Check Part 6 Service Diagnosis 143 09 12 class 18 24 class 1 2 3 4 Multimeter R24538 1 2 3 4 Multimeter...
Страница 150: ...Check SiUS042113E 146 Part 6 Service Diagnosis 18 24 class R24539 DC DC W V U...
Страница 165: ...SiUS042113E Piping Diagrams Part 8 Appendix 161 1 2 Outdoor Unit RXM09 12VVJU RXM18VVJU 3D131979 3D132216...
Страница 166: ...Piping Diagrams SiUS042113E 162 Part 8 Appendix RXM24VVJU 3D132217...
Страница 171: ...SiUS042113E Operation Limit Part 8 Appendix 167 3 Operation Limit RXM09 12 18 24VVJU 3D133582A...