ESIE16-02K
|
Part 3. Repair
3.3. Unit specific repair procedures
Page 72
31/05/21
|
Version 1.1
RA R32 Split & multi split M-Series
3.3.2.2. Replacing switch box
PRELIMINARY ACTIONS
1. Switch off the Daikin unit via the user interface.
2. Switch off the Daikin unit with the field supplied circuit breaker.
3. Remove plate work when required, refer to
.
PROCEDURE
Removal
1. Remove the insulation (1).
2. Unplug all connectors from the main PCB (2), see
"Component checklist" on page 129
.
3. Remove all electrical power wiring (3) from the wire terminals (4).
4. Remove the screws (5) that fix the wire clamp (6), remove the wire clamp (6).
5. Remove the screws (7) that fix the right side plate assembly (8).
6. Cut the cable tie (9).
7. Lift the switch box (10) from the Daikin unit.
W
ARNING
: R
ISK
OF
F
IRE
When reconnecting a connector to the PCB, do not apply force, as this may damage the connector or connector pins of
the PCB.