8 Disposal
Operation manual
11
FTXF20~3 FTXF20~25B5V1B
Daikin room air conditioner
3P520336-3E – 2019.09
7.1.7
Symptom: White mist comes out of a unit
(Indoor unit)
▪ When humidity is high during cooling operation (in oily and dusty
places). If the interior of an indoor unit is extremely contaminated,
the temperature distribution inside a room becomes uneven. It is
necessary to clean the interior of the indoor unit. Ask your dealer
for details on cleaning the unit. This operation requires a qualified
service person.
▪ When the air conditioner is changed over to heating operation
after defrost operation. Moisture generated by defrost becomes
steam and exits.
7.1.8
Symptom: The units can give off odours
The unit can absorb the smell of rooms, furniture, cigarettes, etc.,
and then emit it again.
7.1.9
Symptom: The outdoor fan rotates while
the air conditioner is not in operation
▪
After operation has stopped.
The outdoor fan continues to
rotate for another 30 seconds for system protection.
▪
While the air conditioner is not in operation.
When the outdoor
temperature is very high, the outdoor fan starts to rotate for
system protection.
7.2
Solving problems based on error
codes
If the unit runs into a problem, the user interface displays an error
code. It is important to understand the problem and to take
measures before resetting an error code. This should be done by a
licensed installer or by your local dealer.
This chapter gives you an overview of all possible error codes and
their descriptions as they appear on the user interface.
For detailed troubleshooting of each error, see the service manual.
Fault diagnosis by user interface
The user interface can receive an error code from the indoor unit
referring to the fault. It is important to understand the problem and
take measures before resetting the error code. This should be done
by a licensed installer or your local dealer.
To see the error code on the user interface:
1
Hold
for about 5 seconds.
Result:
blinks in the temperature display section.
2
Press
repeatedly until a continuous beep is heard.
Result:
The code is now displayed on the display.
INFORMATION
▪ A short beep and 2 consecutive beeps indicate non-
corresponding codes.
▪ To cancel the code display, hold the
cancel
button for 5 seconds. The code will also disappear from
the display if the button is NOT pressed within
1 minute.
System
Error code
Description
Normal
Refrigerant shortage
Overvoltage detection
Signal transmission error (between indoor and
outdoor unit)
Indoor/outdoor unit combination fault
Indoor unit
Error code
Description
Indoor unit PCB abnormality
Freeze-up protection or high-pressure control
Fan motor (DC motor) abnormality
Room temperature thermistor abnormality
Outdoor unit
Error code
Description
4-way valve abnormality
Outdoor unit PCB abnormality
Overload activation (compressor overload)
Compressor lock
DC fan lock
Input power overcurrent
Discharge pipe temperature control
High-pressure control (in cooling mode)
Compressor system sensor abnormality
Position sensor abnormality
DC voltage / current sensor abnormality
Outdoor temperature thermistor abnormality
Discharge pipe thermistor abnormality
Outdoor heat exchanger thermistor abnormality
Electrical parts heat error
Radiation fin temperature rise
Inverter instantaneous overcurrent (DC)
Radiation fin thermistor abnormality
Compressor internal temperature error
8
Disposal
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.