manualshive.com logo in svg
background image

Deutsch

English

Français

Nederlands

Español

Italiano

ÅëëçíéêÜ

Portugues

Russian

FTXS50BVMB FTKS50BVMB

FTXS60BVMB FTKS60BVMB

FTXS71BVMB FTKS71BVMB

MODELS

DAIKIN ROOM AIR CONDITIONER

Operation Manual

Cover.fm  Page 1  Thursday, August 22, 2002  7:21 PM

Содержание FTKS50BVMB

Страница 1: ...is Nederlands Español Italiano ÅëëçíéêÜ Portugues Russian FTXS50BVMB FTKS50BVMB FTXS60BVMB FTKS60BVMB FTXS71BVMB FTKS71BVMB MODELS DAIKIN ROOM AIR CONDITIONER Operation Manual Cover fm Page 1 Thursday August 22 2002 7 21 PM ...

Страница 2: ... 0211 HT 3P098586 1 M02B051 Cover fm Page 2 Thursday August 22 2002 7 21 PM ...

Страница 3: ...FAN Operation 10 Adjusting the Air Flow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT SILENT Operation 15 HOME LEAVE Operation 16 INTELLIGENT EYE Operation 18 TIMER Operation 20 Note for Multi System 22 CARE Care and Cleaning 24 TROUBLE SHOOTING Trouble Shooting 27 3P098586 1_Eng_1 book Page 1 Wednesday November 27 2002 11 31 AM ...

Страница 4: ...e staff Do not attempt to install the air conditioner by your self Incorrect work will result in water leakage electric shocks or fire For installation consult the dealer or a qualified technician In order to avoid electric shock fire or injury if you detect any abnormally such as smell of fire stop the operation and turn off the breaker And call your dealer for instructions CAUTION The air condit...

Страница 5: ...unit with excessive water only use a slightly wet cloth Do not place things such as vessels containing water or anything else on top of the unit Water may penetrate into the unit and degrade electrical insulations resulting in an electric shock To install the air conditioner in the following types of environments consult the dealer Places with an oily ambient or where steam or soot occurs Salty en...

Страница 6: ...4 Names of parts Indoor Unit Main unit control panel 7 14 11 12 13 4 3 15 1 2 9 10 8 6 5 The illustration shows a 50 class unit 17 16 3P098586 1_Eng_1 book Page 4 Wednesday November 27 2002 11 31 AM ...

Страница 7: ...ce again to stop it The operation mode refer to the following table This switch is useful when the remote controller is missing 15 Packaging materials 50 class only If any packaging materials are included please remove before operating page 24 16 Room temperature sensor It senses the air temperature around the unit 17 Signal receiver It receives signals from the remote controller When the unit rec...

Страница 8: ...selects the operation mode AUTO DRY COOL HEAT FAN page 10 8 SILENT button for OUTDOOR UNIT SILENT operation page 15 9 FAN setting button It selects the air flow rate setting 10 SENSOR button for INTELLIGENT EYE operation page 18 11 SWING button page 12 Flap Horizontal blade 12 SWING button page 12 Louver Vertical blades 13 ON TIMER button page 21 14 OFF TIMER button page 20 15 TIMER Setting button...

Страница 9: ...ot used for a long time take the batteries out We recommend replacing once a year although if the remote controller display begins to fade or if reception deteriorates please replace with new alkali batteries Using manganese batteries reduces the lifespan The attached batteries are provided for the initial use of the system The usable period of the batteries may be short depending on the manufactu...

Страница 10: ...h the screws supplied with the holder 3 Place the remote controller in the remote controller holder ATTENTION About remote controller Never expose the remote controller to direct sunlight Dust on the signal transmitter or receiver will reduce the sensitivity Wipe off dust with soft cloth Signal communication may be disabled if an electronic starter type fluorescent lamp such as inverter type lamps...

Страница 11: ... turn the breaker OFF Use the air conditioner in the following conditions Operation outside this humidity or temperature range may cause a safety device to disable the system C TEMP ON OFF POWERFUL HOME LEAVE MODE TIMER FAN SILENT SWING ON CANCEL OFF SENSOR 1 3 2 Recommended temperature setting For cooling 26 C 28 C For heating 20 C 24 C Mode Operating conditions If operation is continued out of t...

Страница 12: ...EAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION lamp goes off To change the temperature setting 4 Press TEMPERATURE adjustment button DRY or FAN mode AUTO or COOL or HEAT mode The temperature setting is not variable Press to raise the temperature and press to lower the temperature Set to the temperature you like C TEMP ON OFF ...

Страница 13: ...ration it takes some time before the room gets warmer In heating operation frost may occur on the outdoor unit and lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting operation hot air does not flow out of indoor unit Note on DRY operation The computer chip works to rid the room of humidity while maintaining the temperature...

Страница 14: ... once more The display will go blank The flap will stop moving To adjust the vertical blades louvers 3 Press SWING button The display will light up and the louvers will begin to swing 4 When the louvers have reached the desired position press the SWING button once more The display will go blank The louvers will stop moving C TEMP ON OFF POWERFUL HOME LEAVE MODE TIMER FAN SILENT SWING ON CANCEL OFF...

Страница 15: ...w Using three dimensional airflow circulates cold air which tends to collected at the bottom of the room and hot air which tends to collect near the ceiling throughout the room preventing areas of cold and hot developing ATTENTION Always use a remote controller to adjust the flaps angle If you attempt to move it forcibly with hand when it is swinging the mechanism may be broken Be careful when adj...

Страница 16: ...OWERFUL button again NOTE Notes on POWERFUL operation In COOL and HEAT mode To maximize the cooling heating effect the capacity of outdoor unit must be increased and the air flow rate be fixed to the maximum setting The temperature and air flow settings are not variable In DRY mode The temperature setting is lowered by 2 5 C and the air flow rate is slightly increased In FAN mode The air flow rate...

Страница 17: ...operation is set on all operated indoor units However if using priority room setting see Note for multi system page 22 This function is available in COOL HEAT and AUTO modes This is not available in FAN and DRY mode POWERFUL operation and OUTDOOR UNIT SILENT operation cannot be used at the same time Priority is given to POWERFUL operation If operation is stopped using the remote controller or the ...

Страница 18: ...VE operation Record your preferred temperature and air flow rate 1 Press HOME LEAVE button Make sure is displayed in the remote controller display 2 Adjust the set temperature with or as you like 3 Adjust the air flow rate with FAN setting button as you like Home leave operation will run with these settings the next time you use the unit To change the recorded information repeat steps 1 3 C TEMP O...

Страница 19: ...Push the HOME LEAVE Operation button again and the air conditioner will adjust capacity to the set temperature for normal operation Set the unit to HOME LEAVE Operation before leaving the living room when going to bed The unit will maintain the temperature in the room at a comfortable level while you sleep When you enter the living room in the morning the temperature will be just right Disengaging...

Страница 20: ...NTELLIGENT EYE operation 2 Press SENSOR button again EX C TEMP ON OFF POWERFUL HOME LEAVE MODE TIMER FAN SWING SILENT ON CANCEL OFF SWING 1 2 SENSOR When somebody in the room Normal operation When nobody in the room 20 min after start energy saving operation Somebody back in the room Back to normal operation 3P098586 1_Eng_1 book Page 18 Wednesday November 27 2002 11 31 AM ...

Страница 21: ...The sensor also mistakenly detects pets sunlight fluttering curtains and light reflected off of mirrors as passersby INTELLIGENT EYE operation will not go on during powerful operation Night set mode page 20 will not go on during you use INTELLIGENT EYE operation Do not place large objects near the sensor Also keep heating units or humidifiers outside the sensor s detection area This sensor can det...

Страница 22: ...MER lamp lights up To cancel the OFF TIMER Operation 4 Press CANCEL button The TIMER lamp goes off Notes When TIMER is set the present time is not displayed Once you set ON OFF TIMER the time setting is kept in the memory The memory is canceled when remote controller batteries are replaced When operating the unit via the ON OFF Timer the actual length of operation may vary from the time entered by...

Страница 23: ...MER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for combining the two timers is shown below ATTENTION In the following cases set the timer again After a breaker has turned OFF After a power failure After replacing batteries in the remote controller C TEMP ON OFF POWERFUL HOME LEAVE MODE TIMER FAN SILEN...

Страница 24: ...ase consult your retailer or dealer for assistance NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent annoyance to neighbors The NIGHT QUIET Mode is activated when the temperature drops 5 C or more below the highest temperature recorded that day Therefore when the temperature difference is less than 5 C this function will not be activated NIGHT ...

Страница 25: ...ERFUL operation operation capacity will be concentrated in Room A In such a case the cooling heating efficiency of the units in Rooms B C and D may be slightly reduced 3 Priority when using OUTDOOR UNIT SILENT operation Example Room A is the Priority Room in the examples Just by setting the unit in Room A to SILENT operation the air conditioner starts OUTDOOR UNIT SILENT operation You don t have t...

Страница 26: ...n dowels on the left and right of the front panel with the slots then push them all the way in Close the front panel slowly Press the panel at both sides and the center CAUTION Units When the packaging materials are attached to the front panel please remove them Don t touch the metal parts of the indoor unit If you touch those parts this may cause an injury When removing or attaching the front gri...

Страница 27: ...lukewarm water then dry them up in the shade It is recommended to clean the air filters every two weeks Air purifying filter with photocatalytie deodorizing function gray The air purifying capacity of the photocatalytic purifying filter can be renewed by washing it with water once every 6 months We recommend replacing it once every 3 years Maintenance 1 Remove dust with a vacuum cleaner and wash l...

Страница 28: ...door unit and the outdoor unit Check that the earth wire is not disconnected or broken Check that the drain comes smoothly out of the drain hose during COOL or DRY operation If no drain water is seen water may be leaking from the indoor unit Stop operation and consult the service shop if this is the case Operation with dirty filters 1 cannot deodorize the air 2 cannot clean the air 3 results in po...

Страница 29: ...n In COOL or DRY mode Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mists come out of the indoor unit This happens when the air in the room is cooled into mist by the cold air flow during cooling operation The indoor unit gives out odour This happens when smells of the room furniture or cigarettes are absorbed into the unit and discharged with the ai...

Страница 30: ...ir filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with the remote controller If the lamp still blinks call the service shop where you bought the air conditioner Are operation modes all the same for indoor units connected to outdoor units in the multi system If not set all indoor units to the same operation mode and confirm th...

Страница 31: ...asons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist maintenance contact the service shop where you bought the air conditioner The maintenance cost must be born by the user Call the service shop immediately After a power failure The air conditioner automatically resumes operation in about ...

Страница 32: ...RE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OPERATION HALT DUE TO DETECTION OF INPUT OVER CURRENT F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR H8 CT ABNORMALITY H9 FAULTY SUCTION AIR TEMPERATURE SENSOR J3 FAULTY DISCHARGE PIPE TEMPERATURE SENSOR J6 FAULTY HEAT ...

Страница 33: ...PROTECTOR WORKED OR FREEZE UP IN OPERATING UNIT OR STAND BY UNIT OVERLOAD RELAY WORKED OR HIGH DISCHARGE PIPE TEMPERATURE FAULTY COMPRESSOR START INPUT OVERCURRENT THERMISTOR OR CT ABNORMALITY HIGH TEMPERATURE SWITCHBOX HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK OUTPUT OVERCURRENT REFRIGERANT SHORTAGE LOW VOLTAGE TO MAIN CIRCUIT OR MOMENTARY VOLTAGE LOSS REVERSING SOLENOID VALVE SWITCHING FAILU...

Страница 34: ...32 MEMO 3P098586 1_Eng_1 book Page 32 Wednesday November 27 2002 11 31 AM ...

Отзывы: