SiENBE12-713
Main Functions
Function and Control
71
1.10 INTELLIGENT EYE (Wall Mounted Type Only)
This is the function that detects existence of humans in the room by a human motion sensor
(INTELLIGENT EYE) and reduces the capacity when there is no human in the room in order to
save electricity.
Processing
1. Detection method by Intelligent Eye
"
This sensor detects human motion by receiving infrared rays and displays the pulse wave
output.
"
A microcomputer in an indoor unit carries out a sampling every 20 msec. and if it detects 10
cycles of the wave in one second in total (corresponding to 20msec.× 10 = 100msec.), it
judges human is in the room as the motion signal is ON.
2. The motions (for example: in cooling)
"
When a microcomputer doesn’t have a signal from the sensor in 20 minutes, it judges that
nobody is in the room and operates the unit in temperature shifted 2°C from the set
temperature. (Cooling : 2°C higher, Dry: 1°C higher and Auto : according to the operation
mode at that time.)
H
1 In case of Fan mode, the fan speed reduces by 50 rpm.
1
s
ec
sa
mpling (20m
s
ec)
High
Low
ON
OFF
S
en
s
or o
u
tp
u
t
(H
u
m
a
n motion)
(R2
8
21)
H
u
m
a
n detection
s
ign
a
l
If the
s
en
s
or detect
s
the o
u
tp
u
t
s
10 time
s
/
s
ec.
or more, it j
u
dge
s
h
u
m
a
n
s
exi
s
t.
ON
OFF
RE
S
ET.
(R2
8
22)
within 20
min
u
te
s
.
H
u
m
a
n detection
s
ign
a
l
Cooling :
S
et temp. + 2°C
He
a
ting :
S
et temp. - 2°C
S
et temp.
M
a
xHz
Compre
ss
or
s
peed
MinHz
0Hz
Remote control
Intelligent Eye
bu
tton
Oper
a
tion
F
a
n
s
peed (
H
1)
ON
OFF
ON
OFF
OFF
S
et
s
peed
S
et
s
peed - 50 rpm
The lower limit
b
y detecting
h
u
m
a
n. (Prohi
b
ition of
thermo
s
t
a
t-off)
S
et
s
peed
in c
as
e of
thermo
s
t
a
t-off
Fre
qu
ency
a
t
s
et temp. + 2°C
20 min.
40 min.
20 min.
Содержание FTKS20D3VMW
Страница 11: ...Introduction SiENBE12 713 x...
Страница 47: ...Specifications SiENBE12 713 36 Specifications...
Страница 113: ...Control Specification SiENBE12 713 102 Function and Control...
Страница 122: ...SiENBE12 713 Instruction System Configuration 111 Names of Parts FTK X S 20 25 35 C Indoor Unit...
Страница 235: ...Instruction SiENBE12 713 224 System Configuration...
Страница 297: ...Check SiENBE12 713 286 Service Diagnosis...
Страница 316: ...SiENBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points...
Страница 330: ...SiENBE12 713 Others 319 Part 8 Others 1 Others 320 1 1 Test Run from the Remote Control 320 1 2 Jumper Settings 321...