Troubleshooting
SiENBE12-713
242
Service Diagnosis
5.6
Thermistor or Related Abnormality (Indoor Unit)
Remote Control
Display
C4, C9
Method of
Malfunction
Detection
The temperatures detected by the thermistors are used to determine thermistor errors.
Malfunction
Decision
Conditions
When the thermistor input is more than 4.96 V or less than 0.04 V during compressor
operation
∗
.
∗
(reference)
When above about 212°C (less than 120 ohms) or below about -50°C (more than 1,860 kohms).
Note:
The values vary slightly in some models.
Supposed
Causes
"
Faulty connector connection
"
Faulty thermistor
"
Faulty PCB
Troubleshooting
Check No.06
Refer to P.279
C4
: Heat exchanger temperature thermistor
C9
: Room temperature thermistor
Check the connector connection.
YE
S
Correct the connection.
Repl
a
ce the thermi
s
tor.
(Repl
a
ce the indoor
u
nit PCB.)
Repl
a
ce the indoor
u
nit PCB.
I
s
it norm
a
l?
I
s
it norm
a
l?
(R4696)
NO
Check No. 06
Thermi
s
tor re
s
i
s
t
a
nce check
YE
S
NO
Caution
Be
su
re to t
u
rn off power
s
witch
b
efore connect or di
s
connect connector,
or p
a
rt
s
d
a
m
a
ge m
a
y
b
e occ
u
rred.
Содержание FTKS20D3VMW
Страница 11: ...Introduction SiENBE12 713 x...
Страница 47: ...Specifications SiENBE12 713 36 Specifications...
Страница 113: ...Control Specification SiENBE12 713 102 Function and Control...
Страница 122: ...SiENBE12 713 Instruction System Configuration 111 Names of Parts FTK X S 20 25 35 C Indoor Unit...
Страница 235: ...Instruction SiENBE12 713 224 System Configuration...
Страница 297: ...Check SiENBE12 713 286 Service Diagnosis...
Страница 316: ...SiENBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points...
Страница 330: ...SiENBE12 713 Others 319 Part 8 Others 1 Others 320 1 1 Test Run from the Remote Control 320 1 2 Jumper Settings 321...