2.3.3 Four Way Valve Operation Compensation
Outline
At the beginning of operation as the four way valve is switched, the pressure difference to activate
the four way valve is acquired when the output frequency is higher than a certain fixed frequency,
for a certain fixed time.
Details
Starting Conditions
1. When the compressor starts and the four way valve switches from OFF to ON
2. When the four way valve switches from ON to OFF during operation
3. When the compressor starts after resetting
4. When the compressor starts after the fault of four way valve switching
The lower limit of frequency keeps
A
Hz for
B
seconds with any conditions 1 through 4 above.
When the outdoor temperature is above
C
in heating, the frequency decreases depending on the
outdoor temperature.
2.3.4 3-Minute Standby
Turning on the compressor is prohibited for 3 minutes after turning it off.
(The function is not activated when defrosting.)
2.3.5 Compressor Protection Function
When turning the compressor from OFF to ON, the upper limit of frequency is set as follows.
(The function is not activated when defrosting.)
09/12 class
15/18 class
Cooling
Heating
Cooling
Heating
A
(Hz)
40
54
48
B
(seconds)
60
70
C
(°C)
10
15
(°F)
50
59
09/12 class
15/18 class
A
(Hz)
40
52
B
(Hz)
54
68
C
(Hz)
72
80
D
(Hz)
90
—
E
(Hz)
—
—
F
(seconds)
180
300
G
(seconds)
420
200
H
(seconds)
180
460
J
(seconds)
120
—
K
(seconds)
—
—
(sec.)
Time
(R23251)
(Hz)
Frequency
C
D
E
B
F
G
H
J
K
A
Содержание FFQ09Q2VJUFFQ12Q2VJUFFQ15Q2VJUFFQ18Q2VJURX09QMVJURX12QMVJURX15QMVJURX18QMVJU
Страница 12: ...SiUS091628EA 1 List of Functions Part 1 List of Functions 1 Functions 2...
Страница 14: ...SiUS091628EA 3 Specifications Part 2 Specifications 1 Specifications 4...
Страница 120: ...Check SiUS091628EA 109 Service Diagnosis 15 18 class R20701 1 2 3 4 Multimeter...
Страница 122: ...Check SiUS091628EA 111 Service Diagnosis 15 18 class R20704 W V U DC_P1 DC_N1...