Installer reference guide
Split system air conditioners
English
FDXM25F3V1BFDXM35F3V1BFDXM50F3V1BFDXM60F3V1B
Страница 1: ...Installer reference guide Split system air conditioners English Installer reference guide Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B...
Страница 2: ...ca acestea s fie utilizate n conformitate cu instruc iunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na imi navodili on vastavuses j rgmis...
Страница 3: ...cal wiring 13 6 4 1 About connecting the electrical wiring 13 6 4 2 Precautions when connecting the electrical wiring 13 6 4 3 Guidelines when connecting the electrical wiring 13 6 4 4 To connect the...
Страница 4: ...ss of fire department police and hospital Name address and day and night telephone numbers for obtaining service In Europe EN378 provides the necessary guidance for this logbook 1 2 2 Installation sit...
Страница 5: ...ately If the valve is not closed immediately remaining pressure might charge additional refrigerant Possible consequence Incorrect refrigerant amount 1 2 4 Brine If applicable See the installation man...
Страница 6: ...TICE Only applicable if the power supply is three phase and the compressor has an ON OFF starting method If there exists the possibility of reversed phase after a momentary black out and the power goe...
Страница 7: ...This chapter contains information about Combining outdoor and indoor units Combining the indoor unit with options 4 2 System layout b c a e d f g h a Indoor unit b Outdoor unit c User interface d Suc...
Страница 8: ...se will NOT disturb anyone WARNING Do NOT place objects below the indoor and or outdoor unit that may get wet In this condition condensation on the main unit or refrigerant pipes air filter dirt or dr...
Страница 9: ...cable legislation Make electrical connections to the fixed wiring All components procured on the site and all electrical construction must comply with the applicable legislation WARNING ALWAYS use mul...
Страница 10: ...2 hooks for 25 35 type 3 hooks for 50 60 type rear suction bottom suction 2 1 2 1 Install the unit temporarily 6 Attach the hanger bracket to the suspension bolt 7 Fix the unit securely Level Make su...
Страница 11: ...d is less than 4 mm from the metal clamp part 3 Check for water leaks see To check for water leaks 4 Install the insulation piece drain pipe 5 Wind the large sealing pad insulation around the metal cl...
Страница 12: ...1 month Pinch or tape the pipe Indoor unit Regardless of the period INFORMATION Do NOT open the refrigerant stop valve before checking the refrigerant piping When you need to charge additional refrig...
Страница 13: ...ly flammable a a Refer to the outdoor unit specifications for the type of refrigerant to be used Pipe length Keep refrigerant piping as short as possible Flare connections Connect refrigerant piping t...
Страница 14: ...l 1 Remove the service cover b a c d e e f g g A B A Outside the unit B Inside the unit a Control box cover b Connection of interconnection cable including earth c Wiring diagram d Connection of user...
Страница 15: ...es or reversed phases The system is properly earthed and the earth terminals are tightened The fuses or locally installed protection devices are installed according to this document and have not been...
Страница 16: ...s are closed The air inlet or air outlet is blocked E7 There is a missing phase in case of three phase power supply units Note Operation will be impossible Turn OFF the power recheck the wiring and sw...
Страница 17: ...ERLOADPROTECTOR D V D DIODE Q M THERMOSWITCH DB DIODEBRIDGE R RESISTOR DS DIPSWITCH R T THERMISTOR E H HEATER RC RECEIVER F U FU FORCHARACTERISTICS REFERTOPCBINSIDEYOURUNIT FUSE S C LIMITSWITCH FG CON...
Страница 18: ......
Страница 19: ......
Страница 20: ...4P482333 1 2017 03 Copyright 2017 Daikin...