17 Technical data
Installation and operation manual
20
FDA125A5VEB
Split system air conditioners
4P494410-1D – 2022.10
M
C1/SW
C2/—
External static pressure
(1)
13(23)
6
01
40
02
50
03
60
04
70
05
80
06
90
07
100
08
110
09
120
10
130
11
140
12
150
13
160
14
180
15
200
Time to clean air filter
This setting must correspond with the air contamination in the room.
It determines the interval at which the
TIME TO CLEAN AIR FILTER
notification is displayed on the user interface. When using a wireless
user interface, you must also set the address (see the installation
manual of the user interface).
If you want an interval of…
(air contamination)
ThenFN
M
C1/SW
C2/—
±2500 h (light)
10(20)
0
01
±1250 h (heavy)
02
No notification
3
02
▪
2 user interfaces:
When using 2 user interfaces, one must be set
to "MAIN" and the other to "SUB".
17
Technical data
▪ A
subset
of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The
full set
of latest technical data is available on the Daikin
Business Portal (authentication required).
17.1
Wiring diagram
17.1.1
Unified wiring diagram legend
For applied parts and numbering, refer to the wiring diagram on the
unit. Part numbering is by Arabic numbers in ascending order for
each part and is represented in the overview below by "*" in the part
code.
Symbol
Meaning
Symbol Meaning
Circuit breaker
Protective earth
Connection
Protective earth (screw)
,
Connector
A
,
Rectifier
Symbol
Meaning
Symbol Meaning
Earth
Relay connector
Field wiring
Short-circuit connector
Fuse
Terminal
INDOOR
Indoor unit
Terminal strip
OUTDOOR
Outdoor unit
Wire clamp
Residual current
device
Symbol
Colour
Symbol
Colour
BLK
Black
ORG
Orange
BLU
Blue
PNK
Pink
BRN
Brown
PRP, PPL
Purple
GRN
Green
RED
Red
GRY
Grey
WHT
White
SKY BLU Sky blue
YLW
Yellow
Symbol
Meaning
A*P
Printed circuit board
BS*
Pushbutton ON/OFF, operation
switch
BZ, H*O
Buzzer
C*
Capacitor
AC*, CN*, E*, HA*, HE*, HL*,
HN*, HR*, MR*_A, MR*_B, S*, U,
V, W, X*A, K*R_*, NE
Connection, connector
D*, V*D
Diode
DB*
Diode bridge
DS*
DIP switch
E*H
Heater
FU*, F*U, (for characteristics,
refer to PCB inside your unit)
Fuse
FG*
Connector (frame ground)
H*
Harness
H*P, LED*, V*L
Pilot lamp, light emitting diode
HAP
Light emitting diode (service
monitor green)
HIGH VOLTAGE
High voltage
IES
Intelligent eye sensor
IPM*
Intelligent power module
K*R, KCR, KFR, KHuR, K*M
Magnetic relay
L
Live
L*
Coil
L*R
Reactor
M*
Stepper motor
M*C
Compressor motor
M*F
Fan motor
M*P
Drain pump motor
M*S
Swing motor
MR*, MRCW*, MRM*, MRN*
Magnetic relay
N
Neutral
(1)
Field settings are defined as follows:
•
M
: Mode number –
First number
: for group of units –
Number between brackets
: for individual unit
•
SW
: Setting number /
C1
: First code number
• —: Value number /
C2
: Second code number
•
: Default