SiBE12-713
Troubleshooting
Service Diagnosis
243
5.7
Front Panel Open / Close Fault
Remote
Controller
Display
C7
Method of
Malfunction
Detection
Malfunction
Decision
Conditions
The system will be shut down when the error occurs twice.
Supposed
Causes
Malfunction of the reduction motor
Malfunction or deterioration of the front panel mechanism
Malfunction of the limit switch
Troubleshooting
Note:
You cannot operate the unit by the remote controller when the front panel mechanism breaks
down.
<To the dealers: temporary measure before repair>
1. Pull the plug out or turn the breaker off.
2. Remove the decorative plate.
3. Remove the slot-in panel.
4. Put the plug in or turn the breaker on.
(Wait until the initialization finishes.)
5. Operate the unit by the indoor unit ON/OFF switch.
Restart and check
the movement.
YES
YES
YES
YES
Remove the front panel
and check the movement.
Does it move?
Does it open / close
fully?
Restart.
Does the error code
reappear?
Does it move?
NO
NO
NO
NO
Replace the reduction motor.
Replace the assembly of the
front panel mechanism.
+
Check the movement of the
right and left separately by
hand.
It is supposed such as
deformation of the panel or
stuffed dust.
Find out the cause.
Replace the limit switch.
(R3313)
Caution
Be sure to turn off power switch before connect or disconnect connector,
or parts damage may be occurred.
Содержание F-Series
Страница 1: ... Applied Models Inverter Multi Cooling Only Inverter Multi Heat Pump F Series SiBE12 713 ...
Страница 11: ...Introduction SiBE12 713 x ...
Страница 47: ...Specifications SiBE12 713 36 Specifications ...
Страница 113: ...Control Specification SiBE12 713 102 Function and Control ...
Страница 122: ...SiBE12 713 Instruction Operation Manual 111 FTK X S 20 25 35 C Names of parts Indoor Unit ...
Страница 235: ...Instruction SiBE12 713 224 Operation Manual ...
Страница 297: ...Check SiBE12 713 286 Service Diagnosis ...
Страница 316: ...SiBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points ...
Страница 330: ...SiBE12 713 Others 319 Part 8 Others 1 Others 320 1 1 Test Run from the Remote Controller 320 1 2 Jumper Settings 321 ...