4 User interface
Operation manual
13
EZESHP20 EZLSHP20AUAW1B
Exigo E1500 Trailer Refrigeration Unit
4P726855-1 – 2023.03
4.2.3
To disable automatic road mode start-up
WARNING
When the unit is operating in grid mode and a power
blackout occurs, the automatic road mode start-up function
is activated. This means that the unit will start-up in road
mode.
This function MUST be disabled by the operator when the
cold room is parked in a confined space or an area where
fumes from the engine could become trapped and cause
serious injury or death (e.g. indoor parking, ferry).
o
d
1
On any page, press and hold the button (o) next to the
automatic road/grid mode icon (d).
Result:
Automatic road mode start-up is OFF.
To change the automatic road mode start-up from OFF to ON:
o
d
2
On any page, press (short) the button (o) next to the automatic
road/grid mode icon (d).
Result:
Automatic road mode start-up is ON.
4.2.4
To change an operation mode from ON to
OFF
(e.g. thermoregulation)
o
c
1
In the home page, press the button (o) next to the
thermoregulation icon (c).
c
Result:
The thermoregulation icon (c) goes to grey.
Result:
Thermoregulation mode is set to OFF.
Changing the operation mode from OFF to ON is done in the same
manner.
INFORMATION
When the cold room door is closed, a micro switch (NO
contact) sends a signal to the unit.
4.2.5
To set the Set Point
n
l
j
k
1
Press the "Home page" button (n).
2
Press the "Down" (j) or "Up" (l) button to change the set point.
4.2.6
To select a working mode
On the Home page: