background image

73

SLAVE 3

SLAVE 3

S6S
(S3)

K1P

74

75

76

77

78

79

N

L1

F1

F4

230 V ~

73

24 V ~

K1P

M1P

L2

L3

SLAVE 2

F5

K1P

K1P

F2

F3

74

75

76

77

78

79

73

SLAVE 1

K1P

74

75

76

77

78

79

73

MASTER

S6S
(M)

K1P

74

75

76

77

78

79

S10S
(M)

SLAVE 2

SLAVE 1

M1P

MASTER

LOAD

R8T

N

L1

F1

M4P

F13

230 V ~

73

24 V ~

K4P

M4P

L2

L3

SLAVE 3

SLAVE 3

F14

S6S
(S3)

K4P

K4P

F2

F3

74

75

76

77

78

79

N

L1

F4

F15

230 V ~

73

24 V ~

K3P

M3P

L2

L3

SLAVE 2

F16

K3P

F5

F6

74

75

76

77

78

79

N

L1

F7

F17

230 V ~

73

24 V ~

K2P

M2P

L2

L3

SLAVE 1

F18

K2P

F8

F9

74

75

76

77

78

79

N

L1

F10

F19

230 V ~

73

24 V ~

K1P

M1P

L2

L3

MASTER

F20

S1S

S6S
(M)

K1P

F11

F12

74

75

76

77

78

79

S10S
(M)

M3P

SLAVE 2

M2P

SLAVE 1

M1P

MASTER

R8T

LOAD

K3P

K2P

K1P

N

L1

F1

M4P

F13

230V ~

73

24V ~

K4P

M4P

L2

L3

SLAVE 3

SLAVE 3

F14

S6S
(S3)

K4P

F2

F3

74

75

76

77

78

79

N

L1

F4

F15

230V ~

73

24V ~

K3P

M3P

L2

L3

SLAVE 2

F16

K3P

F5

F6

74

75

76

77

78

79

N

L1

F7

F17

230V ~

73

24V ~

K2P

M2P

L2

L3

SLAVE 1

F18

K2P

F8

F9

74

75

76

77

78

79

N

L1

F10

F19

230V ~

73

24V ~

K1P

M1P

L2

L3

MASTER

F20

S1S

S6S
(M)

K1P

F11

F12

74

75

76

77

78

79

S10S
(M)

M3P

SLAVE 2

M2P

M5P

SLAVE 1

M1P

MASTER

R9T

Y1S

LOAD

K4P

K3P

K2P

K1P

1

2

3

1

2

3

Содержание EWLD120MBYNN

Страница 1: ...INSTALLATION MANUAL EWLD120MBYNN EWLD170MBYNN EWLD240MBYNN EWLD260MBYNN EWLD340MBYNN EWLD400MBYNN EWLD480MBYNN EWLD500MBYNN EWLD540MBYNN Condenserless water cooled water chillers...

Страница 2: ...3 24 V K2P M2P L2 L3 SLAVE 1 F18 K2P F8 F9 74 75 76 77 78 79 N L1 F10 F19 230 V 73 24 V K1P M1P L2 L3 MASTER F20 S1S S6S M K1P F11 F12 74 75 76 77 78 79 S10S M M3P SLAVE 2 M2P SLAVE 1 M1P MASTER R8T L...

Страница 3: ...es 04 Richtlijnen zoals geamendeerd 05 Directivas seg n lo enmendado 06 Direttive come da modifica 07 v 08 Directivas conforme altera o em 09 10 Direktiver med senere ndringer 11 Direktiv med f retagn...

Страница 4: ...evaporator water down to 10 C Daikin Integrated Chiller Network DICN Liquid line solenoid valve Sight glass with moisture indication EWLD120MBYNN EWLD260MBYNN EWLD480MBYNN EWLD170MBYNN EWLD340MBYNN EW...

Страница 5: ...se radio interference in which case the user may be required to take adequate measures The units are designed for indoor installation and should be installed in a location that meets the following req...

Страница 6: ...e performed and the air in the refrigerant piping must be evacuated to a value of 4 mbars absolute by means of a vacuum pump 1 Anchor bolt 2 Washer 3 Rubber plate 4 Row cork or rubber sheet 5 Ground 6...

Страница 7: ...the supplied couplings to the evaporator inlet s Connecting the water outlet pipe containing the outlet water tem perature sensor not for EWLD120 The water outlet pipe containing the outlet water tem...

Страница 8: ...listed in the table below The filter kit supplied with the unit must be installed in front of the evaporator water inlet by means of the supplied couplings as shown in the figure The filter has holes...

Страница 9: ...on the unit the power circuit must be connected to the terminals 2 4 and 6 of the main isolator switch 2 Connect the earth conductor yellow green to the earthing terminal PE Interconnection cables Vol...

Страница 10: ...erature sensor Cable for remote digital controller See remote digital controller in the operation manual 1 A remote digital controller can be connected to the PCB inside the unit by means of a 6 ray c...

Страница 11: ...illed out completely tick when checked standard steps to go through before starting the unit 1 Check for external damage 2 Open all shut off valves indicated by a red label OPEN THIS VALVE BEFORE OPER...

Страница 12: ...s inlet water evaporator temperature and mixed outlet water evaporator temperature This in order to correct a possible measurement fault The default value of the probe offset is equal to 0 Steering th...

Страница 13: ...F all units the pump runs for a time indicated by the setting Slave 3 S3 is configured to operate when its remote start stop switch S6S S3 is pushed by the operator Slave 1 S1 slave 2 S2 and the maste...

Страница 14: ...3 shows the system configuration field wiring and terminals for field wiring of this example Purpose Purpose of this system is to keep a buffer at a constant temperature and to feed a load from this...

Страница 15: ...er circuit The operation of the water chiller is then controlled by the Digital Display Controller Shut down by switching off the controller and the circuit breaker of the power circuit WARNINGS Emerg...

Страница 16: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PW22686 1...

Отзывы: