Installation manual

1

EWAP400~540MBYNN

Packaged air-cooled water chillers

4PW22678-1B

C

ONTENTS

Page

Introduction ....................................................................................... 1

Technical specifications ............................................................................. 1
Electrical specifications ............................................................................. 1
Options and features ................................................................................. 1
Standard supplied accessories.................................................................. 2

Operation range ................................................................................ 2

Main components.............................................................................. 2

Selection of location .......................................................................... 2

Inspecting and handling the unit ....................................................... 2

Unpacking and placing the unit ......................................................... 3

Important information regarding the refrigerant used........................ 3

Preparing, checking and connecting the water circuit ....................... 3

Connecting the water circuit .............................................................. 4

Water charge, flow and quality .......................................................... 4

Piping insulation ................................................................................ 4

Field wiring ........................................................................................ 5

Parts table.................................................................................................. 5
Power circuit and cable requirements ........................................................ 5
Connection of the air-cooled water chiller power supply ........................... 5
Interconnection cables............................................................................... 5
Connection and setup of a DICN system................................................... 5
Cable for remote digital controller .............................................................. 6

Before starting................................................................................... 6

Customization in the service menu ................................................... 7

How to continue................................................................................. 8

Thank you for purchasing this Daikin air conditioner.

I

NTRODUCTION

The Daikin EWAP-MBYNN air-cooled water chillers are designed for
outdoor installation and used for cooling applications only. The units
are available in 3 standard sizes with nominal cooling capacities
ranging from 400 to 540 kW.

The EWAP units can be combined with Daikin fan coil units or air
handling units for air conditioning purposes. They can also be used
for supplying chilled water for process cooling.

The present installation manual describes the procedures for
unpacking, installing and connecting the EWAP units.

Technical specifications

(1)

Electrical specifications

(1)

Options and features

(1)

Options

Suction stop valve

Ampere and voltmeter

Main isolator switch

Dual pressure relief valve on the condenser

Low noise operation

Condenser protection grills

BMS Connection (MODBUS/J-BUS, BACNET, LON)

Inverter fans

Heat recovery

High ESP fans

Features

Stepless capacity control (15%~100%)

Evaporator heater tape

Glycol application for leaving evaporator water down to –10°C

Daikin Integrated Chiller Network (DICN)

Low ambient operation (–15°C)

Liquid line solenoid valve

Sight glass with moisture indication

Voltage free contacts

general operation/pumpcontact

alarm

operation circuit 1

operation circuit 2

Changeable voltage free contacts

100% unit signal

second evaporator pump

free cooling contact

Changeable remote inputs

remote start/stop

dual setpoint

enable/disable capacity limitation

(2)

EWAP400MBYNN
EWAP460MBYNN
EWAP540MBYNN

Packaged air-cooled water chillers

Installation manual

READ THIS MANUAL ATTENTIVELY BEFORE STARTING
UP THE UNIT. DO NOT THROW IT AWAY. KEEP IT IN
YOUR FILES FOR FUTURE REFERENCE.

IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.

IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.

(1) Refer to the engineering data book for the complete list of specifications, 

options and features.

Model EWAP

400

460

540

Refrigerant

R407C

Dimensions HxWxD

(mm)

2250x5901x2238

Weight

• machine weight

(kg)

4842

4965

5088

• operation weight

(kg)

4916

5046

5176

Connections

• water inlet

Ø5" OD (141.3 mm OD)

• water outlet

Ø5" OD (141.3 mm OD)

Model EWAP

400

460

540

Power circuit

• Phase

(kg)

3~

• Frequency

(Hz)

50

• Voltage

(V)

400

• Voltage tolerance

(%)

±10

(2) Can be used for night set back and/or peak power limitation: A kWh-gauge 

is connected to a voltage free contact. If the contact is enabled, the circuit 
will be limited to a preset capacity step.

Содержание EWAP400MBYNN

Страница 1: ...INSTALLATION MANUAL EWAP400MBYNN EWAP460MBYNN EWAP540MBYNN Packaged air cooled water chillers...

Страница 2: ...3 24 V K2P M2P L2 L3 SLAVE 1 F18 K2P F8 F9 74 75 76 77 78 79 N L1 F10 F19 230 V 73 24 V K1P M1P L2 L3 MASTER F20 S1S S6S M K1P F11 F12 74 75 76 77 78 79 S10S M M3P SLAVE 2 M2P SLAVE 1 M1P MASTER R8T L...

Страница 3: ...nderung 03 Directives telles que modifi es 04 Richtlijnen zoals geamendeerd 05 Directivas seg n lo enmendado 06 Direttive come da modifica 07 v 08 Directivas conforme altera o em 09 10 Direktiver med...

Страница 4: ...grills BMS Connection MODBUS J BUS BACNET LON Inverter fans Heat recovery High ESP fans Features Stepless capacity control 15 100 Evaporator heater tape Glycol application for leaving evaporator wate...

Страница 5: ...the unit and the floor is flat to prevent vibration and noise generation 2 The space around the unit is adequate for servicing and the minimum space for air inlet and air outlet refer to the operatio...

Страница 6: ...or I beam frame to support the unit on the roof or it can be installed on a concrete base Ground level mounted The unit must be installed on a solid base It is recommended to fix the unit on a concret...

Страница 7: ...To assure proper operation of the unit the water flow through the evaporator must be within the operation range as specified in the table below and a minimum water volume is required in the system Th...

Страница 8: ...note the following Switch for remote on off Units with status or will be controlled by the remote on off switch connected to the chiller defined as Units with status are controlled by the switch conne...

Страница 9: ...not even for a very short period of time before the following pre commissioning checklist is filled out completely tick when checked standard steps to go through before starting the unit 1 Check for...

Страница 10: ...s to comply Defining of the changeable digital analog inputs and outputs Besides locked inputs and outputs there are a number of changeable inputs and outputs of which the function can be chosen from...

Страница 11: ...from a supervisory system If set to no the supervisory system can only read out values but cannot modify them used to address the PCB indicates the communication protocol If the optional gateway is us...

Страница 12: ...ll units the pump runs for a time indicated by the setting Slave 3 S3 is configured to operate when its remote start stop switch S6S S3 is pushed by the operator Slave 1 S1 slave 2 S2 and the master u...

Страница 13: ...em configuration field wiring and terminals for field wiring of this example Purpose Purpose of this system is to keep a buffer at a constant temperature and to feed a load from this buffer One unit s...

Страница 14: ...Installation manual 11 EWAP400 540MBYNN Packaged air cooled water chillers 4PW22678 1B NOTES...

Страница 15: ...circuit The operation of the water chiller is then controlled by the Digital Display Controller Shut down by switching off the controller and the circuit breaker of the power circuit WARNINGS Emergenc...

Страница 16: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PW22678 1B...

Отзывы: