2 User safety instructions

Operation manual

3

EWAA011~016DA + EWYA009~016DA
Packaged air-cooled water chillers
and packaged air to water heat pumps
4P620244-1B – 2021.02

1

Starting from the home screen, turn the left dial and
go to 

Space heating/cooling

.

4

Space heating/cooling

2

Press the left dial to enter the submenu.

3

Turn the left dial and go to 

Operation range

.

Operation range

4.3

4

Press the left dial to enter the submenu.

2

User safety instructions

Always observe the following safety instructions and regulations.

2.1

General

WARNING

If you are NOT sure how to operate the
unit, contact your installer.

WARNING

This appliance can be used by children
aged from 8 years and above and
persons with reduced physical, sensory
or mental capabilities or lack of
experience and knowledge if they have
been given supervision or instruction
concerning use of the appliance in a
safe way and understand the hazards
involved.

Children SHALL NOT play with the
appliance.

Cleaning and user maintenance
SHALL NOT be made by children
without supervision.

WARNING

To prevent electrical shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet

hands.

▪ Do NOT place any objects containing

water on the unit.

CAUTION

▪ Do NOT place any objects or

equipment on top of the unit.

▪ Do NOT sit, climb or stand on the

unit.

▪ Units are marked with the following symbol:

This  means  that  electrical  and  electronic  products  may  NOT  be
mixed  with  unsorted  household  waste.  Do  NOT  try  to  dismantle
the  system  yourself:  the  dismantling  of  the  system,  treatment  of
the  refrigerant,  of  oil  and  of  other  parts  must  be  done  by  an
authorized installer and must comply with applicable legislation.

Units must be treated at a specialized treatment facility for reuse,
recycling  and  recovery.  By  ensuring  this  product  is  disposed  of
correctly, you will help to prevent potential negative consequences
for  the  environment  and  human  health.  For  more  information,
contact your installer or local authority.

▪ Batteries are marked with the following symbol:

This  means  that  the  batteries  may  NOT  be  mixed  with  unsorted
household  waste.  If  a  chemical  symbol  is  printed  beneath  the
symbol,  this  chemical  symbol  means  that  the  battery  contains  a
heavy metal above a certain concentration.

Possible chemical symbols are: Pb: lead (>0.004%).

Waste batteries must be treated at a specialized treatment facility
for  reuse.  By  ensuring  waste  batteries  are  disposed  of  correctly,
you  will  help  to  prevent  potential  negative  consequences  for  the
environment and human health.

2.2

Instructions for safe operation

WARNING: MILDLY FLAMMABLE
MATERIAL

The refrigerant inside this unit is mildly
flammable.

WARNING

The appliance shall be stored so as to
prevent mechanical damage and in a
well-ventilated room without
continuously operating ignition sources
(example: open flames, an operating
gas appliance or an operating electric
heater).

WARNING

▪ Do NOT pierce or burn refrigerant

cycle parts.

Содержание EWAA011-016DAV3P

Страница 1: ...air to water heat pumps English Operation manual Packaged air cooled water chillers and packaged air to water heat pumps EWAA011 016DAV3P EWAA011 016DAW1P EWAA011 016DAV3P H EWAA011 016DAW1P H EWYA009...

Страница 2: ...settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users...

Страница 3: ...ans that electrical and electronic products may NOT be mixed with unsorted household waste Do NOT try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil...

Страница 4: ...and subsequently into the room when you purge air from the heat emitters or collectors 3 About the system Depending on the system layout the system can Heat up a space Cool down a space INFORMATION H...

Страница 5: ...ature b Desired room temperature To change the desired leaving water temperature You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature...

Страница 6: ...used for SD cards USB connector With a USB memory stick the installer can Update the software This requires a correct config file on the USB memory stick Import the settings generated by E Configurato...

Страница 7: ...Schedule Level 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 4 Space heating cooling Operation mode Operation mode schedule 1 9 Room comfort setpoint Heating comf...

Страница 8: ...r unit f Main zone f1 Installed room thermostat type Unit operation is decided based on the ambient temperature of the dedicated Human Comfort Interface BRC1HHDA used as room thermostat Unit operation...

Страница 9: ...ormation about the outdoor unit 9 Installer settings Restriction Only for the installer Gives access to advanced settings A Commissioning Restriction Only for the installer Perform tests and maintenan...

Страница 10: ...le Unit pump ON OFF In menu You can read out 8 6 Operation modes Current operation mode Example Defrost oil return mode 8 7 About Version information about the system 8 8 Connection status Information...

Страница 11: ...g water temperature 1 Go to 2 Main zone or 3 Additional zone Main zone 2 Additional zone 3 2 Adjust the desired leaving water temperature 20 C 2 a b Main zone 12 C 3 a b Additional zone a Actual leavi...

Страница 12: ...lear an action set its time as the time of the previous action 4 Confirm the changes Result The schedule for Monday is defined The value of the last action is valid until the next programmed action In...

Страница 13: ...mperature the unit relies on its weather dependent curve This curve defines how much the leaving water temperature must be at different outdoor temperatures Because the slope of the curve depends on l...

Страница 14: ...ope offset When slope is selected set slope and go to offset When offset is selected set offset Confirm changes and return to the submenu 5 8 4 Using weather dependent curves Configure weather depende...

Страница 15: ...have to Keep the area around the unit clean Keep the user interface clean with a soft damp cloth Do NOT use any detergents Regularly check if the water pressure is above 1 bar Refrigerant This produc...

Страница 16: ...to the Malfunctioning main menu screen and confirm whether the backup heater can take over the heat load or not When Emergency is set to auto SH reduced DHW off or auto SH reduced DHW on 2 and a heat...

Страница 17: ...by installer 10 1 Configuration wizard Setting Fill in System Backup heater type 9 3 1 Emergency 9 5 Number of zones 4 4 Glycol Filled system overview field setting E 0D Backup heater Voltage 9 3 2 C...

Страница 18: ......

Страница 19: ......

Страница 20: ...4P620244 1B 2021 02 Copyright 2020 Daikin 4P620244 1 B 0000000W Verantwortung f r Energie und Umwelt...

Отзывы: