Advanced user

4.2

Space heating/cooling

To turn room temperature control ON or OFF

1

Go to [C.1]: 

Operation

 > 

Room

.

Operation

Room

Space heating/cooling

On

On

C.1

2

Set operation to 

On

 or 

Off

.

To turn space heating/cooling operation ON or OFF

NOTICE

Room  frost  protection.

  Even  if  you  turn  OFF  space

heating/cooling  operation  ([C.2]: 

Operation

  > 

Space

heating/cooling

),  room  frost  protection  operation  –if

enabled–  can  still  activate.  However,  for  leaving  water
temperature  control  and  external  room  thermostat  control,
the protection is NOT guaranteed.

NOTICE

Water  pipe  freeze  prevention.

  Even  if  you  turn  OFF

space  heating/cooling  operation  ([C.2]: 

Operation

  >

Space heating/cooling

), water pipe freeze prevention –

if enabled– will remain active.

1

Go to [C.2]: 

Operation

 > 

Space heating/cooling

.

Operation

Space heating/cooling

On

On

Room

C.2

2

Set operation to 

On

 or 

Off

.

To change the desired room temperature

During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.

1

Go to [1]: 

Room

.

Room

1

2

Adjust the desired room temperature.

+

21

°C

1

a

b

Room

a

 Actual room temperature

b

 Desired room temperature

To change the desired leaving water temperature

You  can  use  the  leaving  water  temperature  setpoint  screen  to  read
out and adjust the desired leaving water temperature.

1

Go to [2]: 

Main zone

 or [3]: 

Additional zone

.

Main zone

2

Additional zone

3

2

Adjust the desired leaving water temperature.

+

20

°C

2

a

b

Main zone

+

12

°C

3

a

b

Additional zone

a

 Actual leaving water temperature

b

 Desired leaving water temperature

To change the weather-dependent curve for the space heating/
cooling zones

1

Go to the applicable zone:

Zone

Go to …

Main zone – Heating

[2.5] 

Main zone

 > 

Heating WD

curve

Main zone – Cooling

[2.6] 

Main zone

 > 

Cooling WD

curve

Additional zone – Heating

[3.5] 

Additional zone

 >

Heating WD curve

Additional zone – Cooling

[3.6] 

Additional zone

 >

Cooling WD curve

2

Change the weather-dependent curve.

Содержание EWAA006D2V3P

Страница 1: ...oled water chillers and packaged air to water heat pumps English Operation manual Packaged air cooled water chillers and packaged air to water heat pumps EWAA004D2V3P EWAA006D2V3P EWAA008D2V3P EWYA004...

Страница 2: ...to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If NOT request him to do so Keep the documentation for future reference T...

Страница 3: ...ns that electrical and electronic products may NOT be mixed with unsorted household waste Do NOT try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil...

Страница 4: ...uit and subsequently into the room when you purge air from the heat emitters or collectors 3 About the system Depending on the system layout the system can Heat up a space Cool down a space INFORMATIO...

Страница 5: ...eating cooling On On Room C 2 2 Set operation to On or Off To change the desired room temperature During room temperature control you can use the room temperature setpoint screen to read out and adjus...

Страница 6: ...User reference guide 5 Operation INFORMATION Heating is only applicable in case of reversible models 5 1 User interface Overview The user interface has the following components a b c d a Slot for WLA...

Страница 7: ...how a help text related to the current page if available e Right dial The LCD shows an arc on the right side of the display when you can use the right dial Turn then press the right dial Change a valu...

Страница 8: ...ice High Medium Low Schedule 8 1 Energy data Electricity input Produced heat 7 4 Quiet Mode Schedule Level Restrictions 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maxim...

Страница 9: ...r unit f Main zone f1 Installed room thermostat type Unit operation is decided based on the ambient temperature of the dedicated Human Comfort Interface BRC1HHDA used as room thermostat Unit operation...

Страница 10: ...ata and information about the outdoor unit 9 Installer settings Restriction Only for the installer Gives access to advanced settings A Commissioning Restriction Only for the installer Perform tests an...

Страница 11: ...On or Off 5 5 Reading out information To read out information 1 Go to 8 Information Possible read out information In menu You can read out 8 1 Energy data Produced energy consumed electricity and con...

Страница 12: ...Go to 1 Room Room 1 2 Adjust the desired room temperature 21 C 1 a b Room a Actual room temperature b Desired room temperature If scheduling is on after changing the desired room temperature The temp...

Страница 13: ...lear the content of a day schedule 1 Select the day of which you want to clear the content For example Friday Mon Sat Wed Fri Thu Tue Sun User defined 1 C 2 Select Delete Delete Edit Copy 3 Select OK...

Страница 14: ...ent operation The unit operates weather dependent if the desired leaving water temperature is determined automatically by the outdoor temperature It therefore is connected to a temperature sensor on t...

Страница 15: ...t ambient temperatures For example if leaving water temperature is always a bit too cold at different ambient temperatures shift the offset up to equally increase the leaving water temperature for all...

Страница 16: ...of a zone You feel Fine tune with setpoints At regular outdoor temperatures At cold outdoor temperatures Y2 a Y1 a X1 a X2 a OK Cold OK Hot You feel Fine tune with setpoints At regular outdoor tempera...

Страница 17: ...of the error and the error code is displayed on the screen 2 Press in the error screen Result A long description of the error is displayed on the screen 8 2 To check the malfunction history Conditions...

Страница 18: ...emitters or collectors Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure tha...

Страница 19: ......

Страница 20: ...4P688015 1 2022 04 Copyright 2022 Daikin 4P688015 1 0000000Q Verantwortung f r Energie und Umwelt...

Отзывы: