2

EWAA004~008D2 + EWYA004~008D2

Packaged air-cooled water chillers

and packaged air to water heat pumps

4P688015-1 – 2022.04

Table of contents

1 About this document

2

2 User safety instructions

3

2.1

General......................................................................................

3

2.2

Instructions for safe operation ...................................................

3

3 About the system

4

3.1

Components in a typical system layout .....................................

4

4 Quick guide

4

4.1

User permission level ................................................................

4

4.2

Space heating/cooling ...............................................................

5

5 Operation

6

5.1

User interface: Overview ...........................................................

6

5.2

Menu structure: Overview user settings ....................................

8

5.3

Possible screens: Overview ......................................................

9

5.3.1

Home screen...............................................................

9

5.3.2

Main menu screen ......................................................

9

5.3.3

Setpoint screen ........................................................... 10

5.3.4

Detailed screen with values ........................................ 10

5.4

Turning operation ON or OFF ...................................................

11

5.4.1

Visual indication .......................................................... 11

5.4.2

To turn ON or OFF...................................................... 11

5.5

Reading out information ............................................................

11

5.6

Space heating/cooling control ...................................................

11

5.6.1

Setting the space operation mode .............................. 11

5.6.2

To change the desired room temperature................... 12

5.6.3

To change the desired leaving water temperature...... 12

5.7

Schedule screen: Example........................................................

12

5.8

Weather-dependent curve.........................................................

14

5.8.1

What is a weather-dependent curve? ......................... 14

5.8.2

2-points curve ............................................................. 15

5.8.3

Slope-offset curve ....................................................... 15

5.8.4

Using weather-dependent curves ............................... 15

6 Energy saving tips

16

7 Maintenance and service

16

7.1

Overview: Maintenance and service .........................................

16

8 Troubleshooting

17

8.1

To display the help text in case of a malfunction.......................

17

8.2

To check the malfunction history...............................................

17

8.3

Symptom: You are feeling too cold (hot) in your living room.....

17

8.4

Symptom: Unit failure ................................................................

17

8.5

Symptom: The system is making gurgling noises after
commissioning...........................................................................

18

9 Disposal

18

10 Installer settings: Tables to be filled in by

installer

18

10.1

Configuration wizard..................................................................

18

10.2

Settings menu ...........................................................................

18

1

About this document

Thank you for purchasing this product. Please:

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

▪ Request the installer to inform you about the settings that he used

to  configure  your  system.  Check  if  he  has  filled  in  the  installer
settings tables. If NOT, request him to do so.

▪ Keep the documentation for future reference.

Target audience

End users

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you must read before installing

▪ Format: Paper (in the box of the outdoor unit)

Operation manual:

▪ Quick guide for basic usage

▪ Format: Paper (in the box of the outdoor unit)

User reference guide:

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the outdoor unit)

Installer reference guide:

▪ Preparation  of  the  installation,  good  practices,  reference

data, …

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Addendum book for optional equipment:

▪ Additional info about how to install optional equipment

▪ Format: Paper (in the box of the outdoor unit) + Digital files on

http://www.daikineurope.com/support-and-manuals/product-
information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

The original documentation is written in English. All other languages
are translations.

ONECTA app

If set up by your installer, you can use the
ONECTA app to control and monitor the status
of your system. For more information, see:

http://www.onlinecontroller.daikineurope.com/

Breadcrumbs

Breadcrumbs  (example: 

[4.3]

)  help  you  to  locate  where  you  are  in

the menu structure of the user interface.

1

To 

enable

 the breadcrumbs: In the home screen or

main menu screen, press the help button. The
breadcrumbs appear in the top left corner of the
screen.

2

To 

disable

 the breadcrumbs: Press the help button

again.

This document also mentions these breadcrumbs. 

Example:

1

Go to 

[4.3]

Space heating/cooling

 > 

Operation

range

.

This means:

Содержание EWAA006D2V3P

Страница 1: ...oled water chillers and packaged air to water heat pumps English Operation manual Packaged air cooled water chillers and packaged air to water heat pumps EWAA004D2V3P EWAA006D2V3P EWAA008D2V3P EWYA004...

Страница 2: ...to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If NOT request him to do so Keep the documentation for future reference T...

Страница 3: ...ns that electrical and electronic products may NOT be mixed with unsorted household waste Do NOT try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil...

Страница 4: ...uit and subsequently into the room when you purge air from the heat emitters or collectors 3 About the system Depending on the system layout the system can Heat up a space Cool down a space INFORMATIO...

Страница 5: ...eating cooling On On Room C 2 2 Set operation to On or Off To change the desired room temperature During room temperature control you can use the room temperature setpoint screen to read out and adjus...

Страница 6: ...User reference guide 5 Operation INFORMATION Heating is only applicable in case of reversible models 5 1 User interface Overview The user interface has the following components a b c d a Slot for WLA...

Страница 7: ...how a help text related to the current page if available e Right dial The LCD shows an arc on the right side of the display when you can use the right dial Turn then press the right dial Change a valu...

Страница 8: ...ice High Medium Low Schedule 8 1 Energy data Electricity input Produced heat 7 4 Quiet Mode Schedule Level Restrictions 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maxim...

Страница 9: ...r unit f Main zone f1 Installed room thermostat type Unit operation is decided based on the ambient temperature of the dedicated Human Comfort Interface BRC1HHDA used as room thermostat Unit operation...

Страница 10: ...ata and information about the outdoor unit 9 Installer settings Restriction Only for the installer Gives access to advanced settings A Commissioning Restriction Only for the installer Perform tests an...

Страница 11: ...On or Off 5 5 Reading out information To read out information 1 Go to 8 Information Possible read out information In menu You can read out 8 1 Energy data Produced energy consumed electricity and con...

Страница 12: ...Go to 1 Room Room 1 2 Adjust the desired room temperature 21 C 1 a b Room a Actual room temperature b Desired room temperature If scheduling is on after changing the desired room temperature The temp...

Страница 13: ...lear the content of a day schedule 1 Select the day of which you want to clear the content For example Friday Mon Sat Wed Fri Thu Tue Sun User defined 1 C 2 Select Delete Delete Edit Copy 3 Select OK...

Страница 14: ...ent operation The unit operates weather dependent if the desired leaving water temperature is determined automatically by the outdoor temperature It therefore is connected to a temperature sensor on t...

Страница 15: ...t ambient temperatures For example if leaving water temperature is always a bit too cold at different ambient temperatures shift the offset up to equally increase the leaving water temperature for all...

Страница 16: ...of a zone You feel Fine tune with setpoints At regular outdoor temperatures At cold outdoor temperatures Y2 a Y1 a X1 a X2 a OK Cold OK Hot You feel Fine tune with setpoints At regular outdoor tempera...

Страница 17: ...of the error and the error code is displayed on the screen 2 Press in the error screen Result A long description of the error is displayed on the screen 8 2 To check the malfunction history Conditions...

Страница 18: ...emitters or collectors Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure tha...

Страница 19: ......

Страница 20: ...4P688015 1 2022 04 Copyright 2022 Daikin 4P688015 1 0000000Q Verantwortung f r Energie und Umwelt...

Отзывы: