16
|
Technical data
Installer reference guide
244
EPRA14~W1 + ET9W
Daikin Altherma 3 H HT F
4P644739-1 – 2021.02
16.3 Piping diagram: Indoor unit
3D120612B
B1PW
S1L
M3S
M1S
R8T
R2T
R1T
R5T
R7T
A
B
B
l
m
m
a2
a1
d2
d1
c2
c1
g
h
k
k
i
j
B1L
o
j
f
B
b1
f
f
B
b2
f
q
q
q
q
q
q
M
M
X
X
k
p
n
e
B
f
B
f
A
Indoor unit
B1L
Flow sensor
B
Field installed
B1PW
Space heating water pressure sensor
a1
Space heating additional/direct zone – Water IN
(screw connection, 1")
M1S
3-way valve (mixing valve for the main/mixed zone)
a2
Space heating additional/direct zone – Water OUT
(screw connection, 1")
M3S
3-way valve (space heating/domestic hot water)
b1
Space heating main/mixed zone – Water IN (screw
connection, 1")
R1T
Thermistor (water IN)
b2
Space heating main/mixed zone – Water OUT
(screw connection, 1")
R2T
Thermistor (backup heater – water OUT)
c1
DHW – Cold water IN (screw connection, 3/4")
R5T, R8T
Thermistor (tank)
c2
DHW – Hot water OUT (screw connection, 3/4")
R7T
Thermistor (main/mixed zone – water OUT)
d1
Water IN from outdoor unit (screw connection, 1")
S1L
Flow switch
d2
Water OUT to outdoor unit (screw connection, 1")
Screw connection
e
Pump (main/mixed zone)
Flare connection
f
Shut-off valve, male-female 1"
Quick coupling
g
Expansion vessel
Brazed connection
h
Magnetic filter/dirt separator
i
Safety valve
j
Air purge
k
Drain valve
l
Pump (additional/direct zone)
m
Check valve
n
Capillary tube
o
Backup heater