5
|
Operation
User reference guide
30
ETVH/X16S(U)18+9W + ETBH/9W
Daikin Altherma 3 H HT F+W
4P644740-1 – 2021.02
2
Adjust the desired leaving water temperature.
+
–
35
°C
2
a
b
Main zone
+
–
45
°C
3
a
b
Additional zone
a
Actual leaving water temperature
b
Desired leaving water temperature
If scheduling is on after changing the desired leaving water temperature
▪
The temperature will stay the same as long as there is no scheduled action.
▪
The desired leaving water temperature will return to its scheduled value
whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off scheduling.
To turn off leaving water temperature scheduling
1
Go to one of the following:
▪
[2.1]:
Main zone
>
Schedule
▪
[3.1]:
Additional zone
>
Schedule
2
Select
No
.
To enable weather-dependent operation for the leaving water temperature
"5.9.4 Using weather-dependent curves"
5.7 Domestic hot water control
5.7.1 About domestic hot water control
Depending on the DHW tank mode (installer setting), you use a different domestic
hot water control:
▪
Reheat only
▪
Sc reheat
▪
Schedule only
CAUTION
The booster heater permission schedule is used to restrict or allow booster heater
operation based on a weekly program. Advice: In order to avoid unsuccessful
disinfection function, at least allow the booster heater (by the weekly program) for
minimum 4 hours starting from the scheduled start-up of disinfection. If the booster
heater is restricted during disinfection, this function will NOT be successful and the
applicable warning AH will be generated.
Содержание ETVH16S18EA9W
Страница 66: ......
Страница 67: ......
Страница 68: ...4P644740 1 2021 02 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...