ESIE09-08
PCB Layout for EKHBRD 011/014/016 AAV1
Refrigerant Circuit
39
2.5 QA PCB - A5P
QA PCB - single phase
QA PCB - A5P
Legend
white
X809A
X801A
white
Fuse F3U
6,3A 250V
Green
black
X803A
X809A
X801A
X803A
F3U
E3
Connector
Color
Connected to - function
X801A
White
X2M [8 - 9] by V5C
X803A
Black
X27A of main PCB A1P
X809A
White
X9A of invertor PCB A4P
F3U
-
Fuse 6,3A / 250V
E3
Green
Earth