9
|
Configuration
Installer reference guide
104
ERLA EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1A – 2020.05
a
b
d
e
f
c
g
b
c
a
Space heating control (user interface)
b
OFF
c
ON
d
LWT temperature
e
Actual
f
Desired
g
Pump operation
Request
:
Pump operation based on request.
Example:
Using a room thermostat creates a thermo ON/OFF condition. When
there is no demand, the pump is OFF.
Remark:
Request is NOT available in leaving water temperature control.
a
d
e
b
b
c
b
c
c
a
Space heating control (user interface)
b
OFF
c
ON
d
Heating demand (by ext. RT or RT)
e
Pump operation
NOTICE
Water pipe freeze prevention.
Even if you turn OFF the leaving water temperature
(main + additional) control via the home pages (
LWT main
+
LWT add
), water pipe
freeze prevention –if enabled– will remain active.
9.2.3 Quick wizard: Options
DHW pump
#
Code
Description
[A.2.2.A]
[D-02]
DHW pump
:
▪
0 (
No
) NOT installed.
▪
1 (
Secondary rtrn
): Installed for instant hot
water when water is tapped. The end-user sets
the operation timing (weekly schedule time) of
the domestic hot water pump when it should
run. Control of this pump is possible through
the outdoor unit.
▪
2 (
Disinf. shunt
): Installed for disinfection.
It runs when the disinfection function of the
domestic hot water tank is running. No further
settings are needed.
See also illustrations below.
See also:
▪
Содержание ERLA03DAV3
Страница 1: ...Installer reference guide Daikin Altherma 3 R F ERLA03DAV3 EHFZ03S18DJ3V...
Страница 182: ...1 7 Field settings table 6 8 2 ID9E51 Applicable units EHFZ03S18DJ3V Notes 4P596829 1 2019 10...
Страница 189: ......
Страница 190: ......
Страница 191: ......
Страница 192: ...4P596821 1A 2020 05 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...