6
|
Application guidelines
Installer reference guide
46
ERGA04~08EAV3(A) + EHBH/X04+08EA/EJ6V+9W
Daikin Altherma 3 R W
4P629085-1 – 2020.08
b
DHW tank
c
DHW pump (field supply)
d
Heater element (field supply)
e
Non‑return valve (field supply)
f
Shower (field supply)
g
Cold water
h
Domestic hot water OUT
i
Recirculation connection
▪
The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see
"9.3.5 To connect the domestic hot water
▪
If the applicable legislation requires a higher temperature than the maximum
tank setpoint during disinfection (see [2-03] in the field settings table), you can
connect a DHW pump and heater element as shown above.
▪
If applicable legislation requires disinfection of the water piping until the tapping
point, you can connect a DHW pump and heater element (if needed) as shown
above.
Configuration
The indoor unit can control DHW pump operation. For more information, see
6.4.6 DHW pump for tank preheating
Setup
c
a
b
e
d
f
g
h
a
Indoor unit
b
DHW tank
c
DHW pump (field supply)
d
Non‑return valve (field supply)
e
Shower (field supply)
f
Cold water
g
Domestic hot water OUT
h
Recirculation connection
▪
The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see
"9.3.5 To connect the domestic hot water
▪
For the standalone DHW tank: If there is no electrical backup heater in the space
heating circuit, you must install a DHW pump for tank preheating.
Configuration
The indoor unit can control DHW pump operation. For more information, see
6.5 Setting up the energy metering
▪
Via the user interface, you can read out the following energy data:
-
Produced heat
-
Consumed energy
Содержание ERGA04EAV3A
Страница 263: ...11 11...
Страница 264: ...4P629085 1 2020 08 Copyright 2020 Daikin Verantwortung f r Energie und Umwelt...