7.1.3 Installation site requirements of the indoor unit
INFORMATION
Also read the precautions and requirements in the
▪
The indoor unit is designed for indoor installation only and for the following
ambient temperatures:
-
Space heating operation: 5~30°C
-
Space cooling operation: 5~35°C
-
Domestic hot water production: 5~35°C. If EKECBUAF6V is installed, ambient
temperature is limited to 5~32°C.
INFORMATION
Cooling is only applicable in case of reversible models.
▪
Mind the following measurements guidelines:
Maximum refrigerant piping length
(a)
between indoor unit and
outdoor unit
30 m
Minimum refrigerant piping length
(a)
between indoor unit and
outdoor unit
3 m
Maximum height difference between indoor unit and outdoor unit:
When outdoor unit (ERGA06E
▲
V3H
▼
or
ERGA08E
▲
V3H
▼
) is at highest location
30 m
When outdoor unit (ERGA04E
▲
V3
▼
or
ERGA04~08E
▲
V3A
▼
) is at highest location
20 m
When indoor unit is at highest location
20 m
(a)
Refrigerant piping length is the one-way length of liquid piping.
▪
Mind the following spacing installation guidelines:
CAUTION
Install the indoor unit at a minimum distance of 1 m from other heat sources (>80°C)
(e.g. electrical heater, oil heater, chimney) and combustible materials. Otherwise the
unit may be damaged or in extreme cases catch fire.
≥500
00
1≥
≥100
08
4≥
[
]
mm
a
b
a
≥100
a+b
≥600
b
≥300
INFORMATION
Serviceability may be impacted, if the indicated clearances cannot be maintained.