background image

4 Temperature sensor calibration

Operation manual

8

EKRTETS

Room thermostat

4P677096-1 – 2021.10

4

Temperature sensor
calibration

Both the internal temperature sensor of the room thermostat and the
(optional)  external  temperature  sensor  can  be  calibrated.  It  is
recommended  to  calibrate  the  sensor(s)  after  installation.  The
procedure is the same for both the internal temperature sensor and
the optional external temperature sensor.

4.1

To calibrate the temperature
sensor

1

Using a thermometer, measure the temperature in the room at
1.5 m distance from the floor for at least 1 hour.

2

Press  and  hold 

  on  the  room  thermostat  for  5  seconds  to

enter the user menu.

3

Use  to  navigation  keys  to  select  AirC  or  AMbC  parameter,
depending  on  whether  you  want  to  calibrate  the  internal  or
(optional) external temperature sensor.

4

Press OK to modify the selected parameter. By default it is set
to "no".

5

Use 

 and 

 to enter the measured value.

6

Press OK to confirm.

Result: 

The  message  "yes"  is  displayed  and  the  value  is  stored  in

the internal memory of the room thermostat.

If needed, the stored calibration value can be erased by pressing 

.

The message "no" will be displayed, confirming the value has been
erased.

5

Maintenance

5.1

Maintenance safety precautions

WARNING

Before  carrying  out  any  maintenance  or  repair  activities,
stop  system  operation  with  the  room  thermostat,  and  turn
off 

the 

power 

supply 

circuit 

breaker. 

Possible

consequence: 

electrical shock or injury.

NOTICE

To  clean  the  room  thermostat,  do  NOT  use  organic
solvents,  such  as  paint  thinner. 

Possible  consequence:

damage, electrical shock, or fire.

WARNING

Do 

NOT 

wash 

the 

room 

thermostat. 

Possible

consequence: 

electric leakage, electrical shock, or fire.

INFORMATION

When  the  dirt  on  the  surface  cannot  be  removed  easily
while  cleaning  the  room  thermostat,  soak  the  cloth  in
neutral  detergent  diluted  with  water,  squeeze  the  cloth
tightly,  and  clean  the  surface.  Afterwards,  wipe  dry  with  a
dry cloth.

5.2

To clean the user interface

1

Wipe  the  screen  and  other  surface  parts  of  the  user  interface
with a dry cloth.

5.3

To replace the batteries

When    blinks  on  the  room  thermostat  display,  the  batteries  of  the
room  thermostat  need  to  be  replaced.  Once  the  battery  indicator
starts  blinking,  the  room  thermostat  will  still  be  able  to  function  for
±30 days before completely shutting down.

1

Open  the  battery  compartments  on  both  sides  of  the  room
thermostat.

2

Remove the old batteries.

3

Insert new batteries.

4

Close the battery compartments.

Result: 

The room thermostat is ready for use.

INFORMATION

After replacing the batteries, date and time have to be set
again.  See 

"3.1.1  To  set  date  and  time"

  [

4

  3]  for  more

information.

6

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

The system MUST be repaired by a qualified service person.

If  the  system  does  NOT  operate  properly  except  for  the  above
mentioned cases and none of the above mentioned malfunctions is
evident,  investigate  the  system  in  accordance  with  the  following
procedures.

Malfunction

Measure

The thermostat display
is blank and the
thermostat is not
working.

▪ Check  whether  the  battery  insulators

have  been  removed  from  the  battery
compartments.

▪ Check  whether  the  orientation  of  the

batteries in the compartments is correct.

▪ Check  the  battery  capacity  and  replace

the batteries if necessary.

The room thermostat
buttons do not react
when pressed.

Check whether key lock functionality is
enabled. If 

 is visible on the display,

press 

 and 

 simultaneously to unlock

the room thermostat again.

The room thermostat
does not initiate cooling
or heating demand
according to the
setpoint.

▪ Check  whether  the  dew  prevention

function is active.

▪ Check  if  the  receiver  is  in  automatic

mode  and  not  in  a  manal  mode  by
verifying that the push button LED on the
receiver is OFF and not green.

The room temperature
does not match the
setpoint set on the
room thermostat.

▪ Recalibrate 

the 

room 

thermostat

temperature  sensor  (or  the  external
temperature  sensor).See  the  installation
manual for the calibration procedure.

▪ Contact your installer.

The schedule timer
starts up too early.

▪ Check  whether  the  correct  program  is

selected (P1-P9 or U1-U4).

▪ Check whether parameter 07 is enabled

in the user menu.

The time and date are
flashing on the room
thermostat display.

Set the clock as described in 

"3.1 Date and

time"

 [

4

 3].

Содержание EKRTRB

Страница 1: ...Operation manual Room thermostat English Operation manual Room thermostat EKRTRB EKRTETS...

Страница 2: ...ite or via your installer The original documentation is written in English All other languages are translations 2 Room thermostat Overview The EKRTRB room thermostat is a programmable wireless digital...

Страница 3: ...et the other values as desired 4 After setting the last value the room thermostat will ask you to confirm and save your changes Press LED blinking green to save the date and time settings Result The r...

Страница 4: ...timer mode automatically 2 Select the duration with and and press to confirm 3 Adjust the desired setpoint with and 4 Press to start the function Result The room thermostat displays the remaining dur...

Страница 5: ...0 minutes Symbol Setpoint Meaning First step of the day the room thermostat follows the comfort mode temperature setpoint during this step Leaving step optional adds an additional step to the current...

Страница 6: ...ing heating of your reversible unit To make use of reversible mode it must be enabled in the installer settings first For more information see To enable reversible mode 46 To change the unit operation...

Страница 7: ...floor temperature drops below or comes too close to the dew point cooling demand is stopped temporarily to prevent any condensation on the floor While the dew prevention function is active blinks on...

Страница 8: ...he batteries When blinks on the room thermostat display the batteries of the room thermostat need to be replaced Once the battery indicator starts blinking the room thermostat will still be able to fu...

Страница 9: ...aller floor sensor problem is blinking and Err is shown on the room thermostat display Contact your installer humidity measurement problem If after checking all above items it is impossible to fix the...

Страница 10: ......

Страница 11: ......

Страница 12: ...4P677096 1 2021 10 Copyright 2021 Daikin 4P677096 1 0000000X Verantwortung f r Energie und Umwelt...

Отзывы: