2 Product description

Installation and operating manual

12

EKHW(D/C/P)(300/500)(P)B

Daikin Altherma ST (Hot water storage tank)

008.1633099_00 – 06/2020

Economical operation

The  full  area  heat  insulation  of  the  storage  tank  ensures  very  low
heat losses in use and means that the best use is made of the heat
energy being applied.

Modular extension facility

If the heat output of a single hot water storage tank is not adequate,
you can interconnect several storage tanks in a modular manner.

Electronic control

A control system integrated in the heat generator controls all heating
and hot water functions for the direct heating circuit, a mixed heating
circuit  which  can  be  connected  as  an  option  and  a  storage  tank
charging circuit.

2.3

Scope of delivery

▪ Hot water storage tank

▪ Bag of accessories

  2‒6 Content of bag of accessories

a

Carrier loops (only required for transport)

b

Cover screen

c

Hose connection piece for safety overflow

d

Fitting spanner

2.4

Optional accessories

2.4.1

Electric immersion heaters

In  addition  to  the  heating  possibilities  via  the  corrugated  stainless
steel  pipe  heat  exchanger  from  various  different  heat  sources  and
energy  carriers,  the  hot  water  storage  tank  can  also  be  charged
using an electric immersion heater.

Electric immersion heaters applicable for all Altherma ST models:

  2‒2 Overview and technical data

Type

EKBU2C

EKBU6C

Operating voltage

230 V / 50 Hz

230/400 V /

50 Hz

Heating output

2 kW

2, 4, 6 kW

Temperature range

(1)

30-78°C

Cable length

2 m

Heating element length

1.10 m

Electric immersion heater sets applicable for EKHWP in combination
with  heat  pumps  are  available.  Please  look  into  the  technical  data
book  of  the  heat  pump  for  the  appropriate  set  and  for  technical
details.

2.4.2

Non return valves

To  prevent  heat  losses  through  the  connection  lines  when  the
circulation  pump  is  turned  off  and  during  periods  without  drinking
water draw-off (gravitational circulation), circulation brakes should be
built into the connections to the hot water storage tank (see 

"   2‒1

Legend" 

[

4

 6]).

2.4.3

Dirt filter

If  the  hot  water  storage  tank  is  connected  to  a  heating  system  with
steel pipes, radiators or non-diffusion-proof floor heating pipes, slurry
and  swarf  could  enter  the  hot  water  storage  tank  and  cause
blockages, local overheating or corrosion. This can be prevented by
fitting a dirt filter or sludge trap (see price list).

2.4.4

Scalding protection

There is a danger of scalding at hot water temperatures over 60°C.
Fitting  scalding  protection  enables  the  hot  water  temperature  to  be
varied continuously and limited from 35 - 60°C.

▪ Scalding protection VTA32

▪ Screw connection set 1"

▪ Circulation set with scalding protection VTR300

2.4.5

Solar storage tank extension kit

If the heat output of a single hot water storage tank is not adequate
you can interconnect several hot water storage tank modules.

This  means  that  both  the  stainless  steel  heat  exchangers  for  post-
heating  and  the  hot  water  heat  exchangers  are  interconnected  in
accordance with the Tichelmann principle 

"6 Hydraulic" 

[

4

 20].

With  seasonal  variations  in  demand  these  individual  units  can  be
added  or  taken  out  of  service  accordingly.  In  this  way  the  total  hot
water output can be manually matched to the actual demand.

The following components are offered:

▪ Solar storage tank extension kit CON SX

▪ Solar storage tank kit 2 CON SXE

▪ FlowGuard FLG

The  installation  and  operation  of  this  accessory  component  is
described  in  detail  in  the  individual  operating  and  installation
instructions provided.

2.4.6

KFE filling connection

For convenient filling and draining of the hot water storage tank, you
can connect the KFE filling connection (KFE BA).

(1)

Temperature control and a safety temperature limiter (STB) are already integrated in the electric immersion heater. The electric immersion
heater is delivered ready for fitting.

Содержание EKHWCH300B

Страница 1: ...ikin Altherma ST Hot water storage tank English Installation and operating manual Daikin Altherma ST Hot water storage tank EKHWCH300 P B EKHWC500B EKHWCH500 P B EKHWCB500 P B EKHWDH500B EKHWDB500B EK...

Страница 2: ...sed system 19 5 3 Final shutdown 19 6 Hydraulic 20 6 1 Connection schemata 20 6 1 1 Solution for low temperature heat pumps 20 6 1 2 Solution for systems with high hot water demand 21 6 1 3 Solution f...

Страница 3: ...page hereinafter referred to as Hot water storage tank Subject to change and correction Documentation set This document is part of a documentation set The complete set consists of Installation and op...

Страница 4: ...and secure it against unintentional switch on Seals must not be damaged or removed Make sure that the safety valves comply with the requirements of EN 12828 when connecting on the heating side and wit...

Страница 5: ...lurry and swarf could enter the hot water storage tank and cause blockages local overheating or corrosion To prevent possible damage fit a dirt filter or sludge separator into the heating return flow...

Страница 6: ...lar flow S F S G S K S M x Hot water connection 1 all y Cold water connection 1 all z Storage tank charging return flow via 1st heat source 1 S A S B S D S F S G S H S M S O S P aa Storage tank chargi...

Страница 7: ...Hot water storage tank EKHWP500PBx S G Hot water storage tank EKHWP300PBx S Q Hot water storage tank EKHWC500Bx S H Hot water storage tank EKHWCH500Bx S I Hot water storage tank EKHWCB500Bx S J Hot w...

Страница 8: ...2 Product description Installation and operating manual 8 EKHW D C P 300 500 P B Daikin Altherma ST Hot water storage tank 008 1633099_00 06 2020 Unpressurised system DrainBack 2 2 500 l models...

Страница 9: ...2 Product description Installation and operating manual 9 EKHW D C P 300 500 P B Daikin Altherma ST Hot water storage tank 008 1633099_00 06 2020 2 3 300 l models...

Страница 10: ...2 Product description Installation and operating manual 10 EKHW D C P 300 500 P B Daikin Altherma ST Hot water storage tank 008 1633099_00 06 2020 Pressurised system 2 4 500 l P models...

Страница 11: ...generator Depending on the available heat from the sun the entire hot water storage tank can be heated up The stored heat is now used both for hot water generation and for heating support The high to...

Страница 12: ...circulation pump is turned off and during periods without drinking water draw off gravitational circulation circulation brakes should be built into the connections to the hot water storage tank see 2...

Страница 13: ...the heat pump see installation and operating manual of the heat pump and the relevant storage tank connecting kit E Pac Requirement The installation site meets the applicable country specific require...

Страница 14: ...essure maximum 10 bar At higher pressure in the drinking water line a pressure reducer must be installed Connect the pressure relief line to the safety pressure relief valve customer supply and connec...

Страница 15: ...n accordance with country specific guidelines We recommend an insulation thickness of at least 20 mm 3 3 Filling Topping up INFORMATION Any optional accessories must be fitted before filling INFORMATI...

Страница 16: ...and fill the storage tank on the EKHWC EKHWP until water comes out of the safety overflow 3 5 Filling the buffer storage tank 2 416 3 5 Filling the buffer storage tank 2 4 Start up WARNING Units which...

Страница 17: ...er pressure on the heating side 3 bar Yes 11 Are the heat generator and heating system vented Yes 12 Are all hydraulic connections tight leaks Yes 13 Does the installation operate without faults Yes 1...

Страница 18: ...filling connection accessory KFE BA see 5 2 1 With pre mounted KFE filling connection 418 Without solar system INFORMATION Draining with KFE filling connection accessory KFE BA is recommended Alterna...

Страница 19: ...dstill of the solar panel circuit drain in accordance with the installation instructions of the regulating and pump unit 5 3 Final shutdown 1 Disconnect hot water storage tank from all electrical and...

Страница 20: ...0 06 2020 6 Hydraulic 6 1 Connection schemata 6 1 1 Solution for low temperature heat pumps 6 1 Standard connection schematic with heat pump and drain back solar system 1 1 The displayed system schema...

Страница 21: ...6 2020 6 1 2 Solution for systems with high hot water demand 6 2 Standard connection schematic for the incorporation of several hot water storage tanks large installations 1 1 The displayed system sch...

Страница 22: ...ording to local legislation Short name Meaning h Non return valve i Pressure reducer k Manometer l Shut off valve 3UV1 3 way switch valve DHW 3UV2 3 way switch valve cooling 3UV3 3 way switch valve he...

Страница 23: ...again DANGER RISK OF ELECTROCUTION All work performed on live components must be carried out in accordance with the proper procedures otherwise there may be a danger to the life and health of individu...

Страница 24: ...pacity V e Max permissible operating temperature Tmax f Standby heat expenditure in 24 hours at 65 C storage tank temp Qst g Operating pressure of storage water pH2O h Nominal capacity of drinking wat...

Страница 25: ...anger stainless steel 1 4404 Water capacity heat exchanger litres 10 6 Heat exchanger surface area m2 2 14 2nd storage tank charging heat exchanger stainless steel 1 4404 Water capacity heat exchanger...

Страница 26: ...a m2 1 9 1 95 2nd storage tank charging heat exchanger stainless steel 1 4404 Water capacity heat exchanger litres 10 9 Heat exchanger surface area m2 2 2 Pressurised solar heat exchanger stainless st...

Страница 27: ...r stainless steel 1 4404 Water capacity heat exchanger litres 10 9 Heat exchanger surface area m2 2 2 Pressurised solar heat exchanger stainless steel 1 4404 Water capacity heat exchanger litres 3 9 8...

Страница 28: ...ter capacity heat exchanger litres 12 85 10 18 1 Heat exchanger surface area m2 2 66 1 95 3 7 Solar heating backup stainless steel 1 4404 Water capacity heat exchanger litres 3 9 Heat exchanger surfac...

Страница 29: ...3 7 Pressurised solar heat exchanger stainless steel 1 4404 Water capacity heat exchanger litres 3 9 8 7 Heat exchanger surface area m2 0 76 1 69 Solar heating backup stainless steel 1 4404 Water capa...

Страница 30: ...Storage tank charging heat exchanger 1 EKHWCH300Bx EKHWCH300PBx e Heating support heat exchanger EKHWCH500Bx EKHWCH500PBx EKHWCB500Bx EKHWCB500PBx p mbar Pressure drop in millibar m L h Flow rate in...

Страница 31: ...1633099_00 06 2020 8 4 Tightening torque 8 6 Tightening torque Designation Thread size Tightening torque Hydraulic line connections water 1 25 to 30 Nm Electric immersion heater 1 5 max 10 Nm hand ti...

Страница 32: ...on 4 Electronic control 12 E Pac 4 14 22 F Filling 15 Filling water 4 16 Freezing 17 H Hydraulic system 14 20 I Intended use 4 K KFE filling connection 12 18 L Large installations 21 Load bearing capa...

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...008 1633099_00 06 2020 Copyright Daikin Verantwortung f r Energie und Umwelt...

Отзывы: