4PW65343-1A – 10.2010

3.

I

NTRODUCTION

3.1.

This manual

This manual describes how to start up and switch off the unit, set
parameters and configure the schedule timer by means of the
controller, maintain the unit and solve operational problems.

3.2.

General information

Thank you for purchasing the domestic hot water heat pump.

This unit consists out of two parts, a heat pump unit
(EKHVWQ002AAV3) and a domestic hot water tank (EKHHS). Only
this type of domestic hot water tanks can be combined with the heat
pump unit.

The domestic hot water tank is available in two sizes: 200 and 260
litre and can be mounted on top of the heat pump unit. For installation
of the domestic hot water tank on the floor next to the heat pump unit,
the dedicated EKFMHHSAA connection kit is required.

The domestic hot water tank contains an electric heater of 1.5 kW as
backup system.

4.

Q

UICK

 

START

-

UP

 

OF

 

THE

 

UNIT

In this chapter the step-by-step procedure is explained for starting up
domestic water heating.

The more detailed information of how the unit must be operated is
explained in the chapter "Operating the unit" on page 4.

The quick start-up offers the user the possibility to start up the
system before reading the entire manual.

4.1.

Domestic water heating operation
– quick start-up

Schedule timer operation

Continuous operation

Powerful operation

INFORMATION

Refer to the installation manual of the unit for installation
procedures.

Icon 

p

 is displayed

(a)

(a) To display or remove the 

p

 icon press the 

pr

 button.

Schedule timer operation

Push the 

ba

 button

Push the 

Y

 button

Push the 

Y

 button

The 

0

 LED will light up and the 

unit will start according to 
default scheduled time and 
default set point (see 
"Schedule timer operation" on 
page 7)
For changing the default 
values, refer to "Setting the 
schedule timer" on page 6.

The 

0

 LED will light up and the 

unit will start according to 
default scheduled time and to 
auto adaptive set point
For changing the default 
values, refer to "Setting the 
schedule timer" on page 6.

Icon 

p

 is not displayed

(a)

(a) To display or remove the 

p

 icon press the 

pr

 button.

Continuous operation

Push the 

wbi

 or the 

wbj

 button

Push the 

ba

 button

Set the desired domestic hot 

water temperature (e.g. 45°C)

Push the 

Y

 button

Push the 

Y

 button

The 

0

 LED will light up and the 

unit will start continuous 

operation according to set point

The 

0

 LED will light up and the 

unit will start continuous 

operation according to auto 

adaptive set point

Push the 

Y

 button

Icon 

p

 is displayed or not displayed

Powerful (one time water heat-up)

Push the 

P

 button.

Refer to "Powerful domestic water heating operation (

P

)" on page 8.

The 

w

 icon will start blinking (0.2 second interval).

Hot water will be produced rapidly.

Содержание EKHHS200AA1V3

Страница 1: ...OPERATION MANUAL EKHVWQ002AAV3 EKHHS200AA1V3 EKHHS260AA1V3 Domestic hot water heat pump ...

Страница 2: ...ance activities 16 7 3 Standstill 16 8 Troubleshooting 17 9 Disposal requirements 17 The English text is the original instruction Other languages are translations of the original instructions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruc...

Страница 3: ...s a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices NOTICE Indicates situations that may result in equipment or property damage accidents only INFORMATION This symbol identifies useful tips or additional information Electric current Danger of burning and scalding DANGER ELECTRICAL SHOCK Switch off all ...

Страница 4: ...nual 4 1 Domestic water heating operation quick start up Schedule timer operation Continuous operation Powerful operation INFORMATION Refer to the installation manual of the unit for installation procedures Icon p is displayed a a To display or remove the p icon press the pr button Schedule timer operation Push the ba button Push the Y button Push the Y button The 0 LED will light up and the unit ...

Страница 5: ...fers full control over your installation Basic controller functions The basic controller functions are Turning the unit ON OFF Schedule timer continuous mode Selection of features quiet mode refer to page 8 auto adaptive set point control refer to page 9 Temperature set point adjustment refer to page 6 Powerful mode The digital controller supports a power cut off of maximum 2 hours When autorestar...

Страница 6: ...ailable 14 DEFROST MODE ICON d This icon indicates that the defrost mode is active 15 COMPRESSOR ICON ç This icon indicates that the compressor of the heat pump unit is active When freeze protection mode is active this icon is blinking 16 BOOSTER HEATER ICON m This icon indicates that the booster heater is active The booster heater provides auxiliary heating for the domestic hot water tank if a hi...

Страница 7: ...e by 10 minutes 3 Use the wi or wj button to adjust the day of the week Each time the wi or wj button is pressed the next or previous day is displayed 4 Press the button to confirm the current set time and day of the week To leave this procedure without saving press the pr button If no button is pressed for 5 minutes the clock and day of the week will return to their previous setting Setting the sc...

Страница 8: ... command It is clear that the last programmed command may date from the day before Refer to Consulting programmed actions on page 12 INFORMATION Default the schedule timer is set as follows Time Set point temperature Sunday until thursday 7 4 22 6 h 45 C Friday and saturday 5 6 22 6 h 55 C If this does not fullfill the customers demands it has to be set as explained in Programming and consulting th...

Страница 9: ...he desired quiet mode is set through a field setting Refer to the field settings explained in the installation manual for a detailed description how to set one or more field settings Disinfection operation This mode will disinfect the domestic hot water tank by periodically heating the domestic water to a specific temperature During the operation of this mode the w icon will be blinking slowly with 0 ...

Страница 10: ...more actions are programmed for the same day and at the same time only the action with the lowest action number will be executed You can always alter add or remove the programmed actions later Example 1 Example 2 If on mondays the customer is usually at home and uses a lot of hot water the set point for monday will increase untill the required amount of hot water is reached as shown in the figure b...

Страница 11: ...s e g 4 and 5 are not displayed 7 Press the button for 5 seconds to enter the programming mode 8 Use the button to select the action number you would like to program or to modify 9 Use the pi and pj buttons to set the correct action time 10 Use the ba button to select x to switch heating and the controller off 9 set the temperature by means of the wi and wj buttons 11 Repeat steps 8 to 10 to progr...

Страница 12: ...rogramming mode 6 Use the button to select the action number you would like to program or to modify 7 Use the pi and pj buttons to set the correct action time 8 Use the ba button to select or deselect x as action 9 Repeat steps 6 to 8 to program the other actions of the selected mode When all actions have been programmed make sure that the display shows the highest action number you would like to ...

Страница 13: ...i e after pressing the button for 5 seconds press the pr button once You can now select another day by using the pi and pj buttons and restart consulting and programming Copying programmed actions to next day In heating mode program it is possible to copy all programmed actions of a specific day to the next day e g copy all programmed actions from 1 to 2 To copy programmed actions to the next day p...

Страница 14: ...on If the P button is pressed the heat pump module heats up the domestic hot water tank as fast as possible to a predefined setpoint This means that the inverter compressor frequency will be higher then in normal operation mode and that sound level and power consumption can be higher This mode might be usefull when exceptional high hot water consumption depletes all the available domestic hot water...

Страница 15: ...ed defines whether the reheat operation is turned ON 1 or OFF 0 1 Automatic domestic hot water tank temperature set point calculation 1 00 Renewal time for set point calculation The automatic temperature set point calculation is done on a daily basis The algorithm calculates for each day of the week an optimum domestic hot water tank temperature set point To calculate this temperature setpoint the ...

Страница 16: ...lated setting 1 ON 02 Installation related setting 23 00 03 Installation related setting 0 OFF 04 Installation related setting 32 3 Miscellaneous 00 Installation related setting 1 ON 01 Installation related setting 3 02 Installation related setting 0 OFF 03 Installation related setting 0 OFF 4 Miscellaneous 03 Installation related setting 0 04 Installation related setting 1 6 Miscellaneous 00 Inst...

Страница 17: ...dissipate this gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not at a dishwasher clothes washer or other appliance During this procedure there must be no smoking open flame or any electrical appliance operating nearby If hydrogen is discharged through the tap it will probably make a sound as of air escaping Each inspection has to be carried...

Страница 18: ...zed treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative consequences for the environment and human health Please contact the installer or local authority for more information NOTES POSSIBLE CAUSES CORRECTIVE ACTIONS No readings on the remote controller blank display Check if the mains power is still con...

Страница 19: ......

Страница 20: ...4PW65343 1A 10 2010 Copyright 2010 Daikin ...

Отзывы: