background image

 

Operation manual

 

3

 

EKHBRD011~0Y17

 

Indoor unit for air to water heat pump system and options

 

4P402192-1B – 2017.09

 

Remote controller buttons and icons

 

1.

 

ON/OFF BUTTON 

 

The ON/OFF button starts or stops the space heating.

Pressing the ON/OFF button consecutively too many times may
cause malfunction of the system (maximum 20 times per hour).

 

2.

 

OPERATION LED 

 

The operation LED is lit during space heating operation. The
LED blinks if a malfunction occurs. When the LED is OFF, space
heating is inactive while the other operation modes can still be
active.

 

3.

 

OPERATION MODE ICONS 

 

,

 

,

 

These icons indicate the current operation mode(s): space
heating (

 

), domestic water heating (

 

) or quiet mode (

 

).

Within limits, different modes can be combined, e.g. space
heating and domestic water heating. The corresponding mode
icons will be displayed simultaneously.

If the domestic hot water tank is not installed, the 

 

 icon will

never be displayed.

 

4.

 

EXTERNAL CONTROL ICON 

 

This icon indicates that the outdoor unit is working in a forced
operation. As long as this icon is displayed, the remote controller
cannot be operated.

 

5.

 

DAY OF THE WEEK INDICATOR 

 

This indicator shows the current day of the week.

When reading or programming the schedule timer, the indicator
shows the set day.

 

6.

 

CLOCK DISPLAY 

 

The clock display shows the current time.

When reading or programming the schedule timer, the clock
display shows the action time.

 

7.

 

SCHEDULE TIMER ICON 

 

This icon indicates that the schedule timer is enabled.

 

8.

 

ACTION ICONS 

 

These icons indicate the programming actions for each day of
the schedule timer.

 

9.

 

OFF ICON 

 

This icon indicates that the OFF action is selected when
programming the schedule timer.

 

10.

 

INSPECTION REQUIRED 

 

 and 

 

These icons indicate that inspection is required on the
installation. Consult your dealer.

 

11.

 

TEMPERATURE DISPLAY 

 

The display shows the current temperature of the installation
either leaving water temperature or actual room temperature.

When changing the room temperature set point, the set point will
be flashing for 5 seconds and then return to the actual room
temperature.

 

12.

 

SETTING 

 

Not used. For installation purposes only.

 

13.

 

NOT AVAILABLE 

 

This icon is displayed whenever a non-installed option is
addressed or a function is not available. A function not available
can mean insufficient permission level or can mean that a slave
remote controller is used (see installation manual).

 

14.

 

DEFROST/START UP MODE ICON 

 

This icon indicates that the defrost/start up mode is active.

 

15.

 

COMPRESSOR ICON 

 

This icon indicates that the compressor in the outdoor unit of the
installation is active.

 

16.

 

HEATER STEP 

 

If the heater kit option is installed, 

 

 icon indicate that the heater

is operating.

 

17.

 

PUMP ICON 

 

This icon indicates that the circulation pump is active.

 

18.

 

OUTDOOR TEMPERATURE DISPLAY 

 

When this icon is flashing, the outdoor ambient temperature is
displayed. Refer to 

"Temperature read-out mode" on page 10

 for

more information.

 

19.

 

WEATHER DEPENDENT SET POINT ICON 

 

This icon indicates that the controller will adapt the leaving water
temperature set point automatically, based on the outdoor
ambient temperature.

 

20.

 

TEMPERATURE ICON 

 

This icon is displayed when the actual room temperature or
room temperature set point are shown.

The icon is also displayed when the temperature set point is set
in schedule timer programming mode. Refer to 

"Temperature

read-out mode" on page 10

 for more information.

 

21.

 

TEST OPERATION ICON 

 

This icon indicates that the unit runs in test mode.

 

22.

 

FIELD SET CODE 

 

This code represents the code from the field set list. Refer to the

"Field settings table" on page 17

.

 

23.

 

ERROR CODE 

 

This code refers to the error code list and is for service purposes
only. Refer to the error code list in the installation manual.

 

NOTE

 

Remark that pushing the 

 

 button has no

influence on the domestic water heating.
Domestic water heating is only switched on or off
by means of the 

 

 button and/or disabling the

storage schedule timer.

1

3

5

6 23

8

13

33

24

11

18

20

14

4

7
9

12

10
21

32

25

26

22

19

31
30
29

27

28

2

17

15

16

 

Master

Slave

 

Permission

 

level 2

level 3

 

Operation ON/OFF

 

 

Domestic water heating operation 
ON/OFF

 

 

Setting the leaving water temperature

 

 

Setting the room temperature

 

 

Quiet mode ON/OFF

 

 

Weather dependent set point operation 
ON/OFF

 

 

Setting the clock

 

 

Programming the schedule timer

 

 

Schedule timer operation ON/OFF

 

 

 

 

Field settings

 

 

Error code display

 

 

Test operation

 

 

 

 

 = operable

 

4PEN402192-1B_2017_09.book  Page 3  Friday, October 6, 2017  8:45 PM

Содержание EKHBRD011ADV17

Страница 1: ...UAL EKHBRD011ADV17 EKHBRD014ADV17 EKHBRD016ADV17 EKHBRD011ADY17 EKHBRD014ADY17 EKHBRD016ADY17 Indoor unit for air to water heat pump system and options 4PEN402192 1B_2017_09 book Page 1 Friday October 6 2017 8 45 PM ...

Страница 2: ...ledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance INTRODUCTION General information Thank you for purchasing this unit The unit is the indoor part of the air to water ERSQ or ERRQ heat pump The unit is designed for floor standing indoor...

Страница 3: ...orage on page 7 The icon will display Hot water will be produced at next scheduled action When water heat up starts the icon will be blinking 1 second interval Manual storage one time water heat up refer to scheme below Push and hold the button for 5 seconds See Manual storage on page 8 The icon will start blinking 1 second interval Hot water will be produced Reheat continuous keeping the minimum ...

Страница 4: ... NOT AVAILABLE This icon is displayed whenever a non installed option is addressed or a function is not available A function not available can mean insufficient permission level or can mean that a slave remote controller is used see installation manual 14 DEFROST START UP MODE ICON This icon indicates that the defrost start up mode is active 15 COMPRESSOR ICON This icon indicates that the compress...

Страница 5: ...in case not zero will display 31 ROOM TEMPERATURE ADJUST BUTTONS and These multi purpose buttons are used to adjust the current room temperature set point in normal operation mode or in schedule timer programming mode When changing the room temperature set point the set point value on the display will be flashing After 5 seconds the display will show to the actual room temperature 32 QUIET MODE BU...

Страница 6: ...is mode heating will be activated as required by the water temperature set point The set point can be set manually through the schedule timer or weather dependent automatic Selecting space heating operation 1 Use the button to switch ON OFF space heating Icon appears on the display as well as the corresponding water temperature set point The operation LED lights up 2 Use the and buttons to set the...

Страница 7: ...ure Lo_A low outdoor temperature 3 01 High ambient temperature Hi_A high outdoor temperature 3 02 Set point at low ambient temperature Lo_Ti the target outgoing water temperature when the outdoor temperature equals or drops below the low ambient temperature Lo_A Note that the Lo_Ti value should be higher than Hi_Ti as for colder outdoor temperatures i e Lo_A warmer water is required 3 03 Set point...

Страница 8: ...er dependent domestic water heating is turned ON 1 or OFF 0 If enabled the storage set point will be set weather dependent In case of a higher ambient temperature e g during summer time temperature of supply water to the domestic hot water tank will be higher too so that storage temperature set point can be set lower in order to keep the overall equivalent hot water amount the same during the whol...

Страница 9: ...ter storage temperature is reached It can also be stopped at any time by pushing the button NOTE If weather dependent domestic water heating is enabled b 02 the storage temperature will be set automatically and the field setting b 03 will be of no importance NOTE Make sure the domestic hot water is only heated up to the domestic hot water temperature you require Start with a low domestic hot water...

Страница 10: ...f there are no error conditions in leaving or returning water thermistors the heater kit can start to follow emergency operation Other operation modes Start up operation During start up the icon displays indicating that the heat pump is starting up and is not working in a steady state condition Defrost operation In space heating operation or domestic water heating operation freezing of the outdoor...

Страница 11: ...edule timer The actions programmed in the schedule timer will be executed automatically The schedule timer is enabled icon displayed or disabled icon not displayed by pressing the button Space heating Refer to Programming space heating on page 13 Five actions per day of the week can be programmed totalling 35 actions The space heating schedule timer can be programmed in 2 different ways based on t...

Страница 12: ...ctive until the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last programmed command may date from the day before Refer to Consulting programmed actions on page 14 The controller will be switched off operation LED will stop working However the schedule timer icon will stay displayed which means that ...

Страница 13: ...rogram depending on remote controller model 4 or 5 actions can be programmed per mode The same actions are repeated on a daily basis Take your time to enter all data accurately Try to program the actions in a chronological way start with action 1 for the first action and end with the highest number for the last action This is not a requirement but will simplify the interpretation of the program la...

Страница 14: ...tons to set the room temperature 11 Use the button to select to switch heating and the remote controller off to select automatic temperature calculation for leaving water temperature Use the and buttons to set the appropriate shift value refer to Space heating operation on page 5 for more information about weather dependent set point 12 Repeat steps 7 to 10 to program the other actions of the sele...

Страница 15: ... when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted By pressing the button several times you return to previous steps in this procedure and finally return to normal operation 12 You automatically return to step 6 start again to program the following day Consulting programmed actions Consulting space heating domestic water heating or quiet mode is carried out as ...

Страница 16: ...gher action number than the one that is displayed E g when the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted Deleting a mode 1 Press the button to enter the programming consulting mode 2 Select the operation mode you would like to delete by means of the and buttons The actual mode is blinking 3 Press the and button simultaneously for 5 sec...

Страница 17: ...ton for a minimum of 5 seconds to enter FIELD SET MODE The icon 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed to the right 1 2 Press the button to select the appropriate field setting first code 3 Press the button to select the appropriate field setting second code 4 Press the button and button to change the set value of the select field se...

Страница 18: ... low ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 Disinfection operation day selection Fri Mon Sun 02 Disinfection operation start time 23 00 0 00 23 00 1 00 hour 5 Automatic setback and disinfection set point 00 Set point disinfection operation temperature 70 60 75 5 C 01 Dis...

Страница 19: ... C 04 Automatic maximum hot water tank storage temperature 70 55 75 1 C C Leaving water temperature limits 00 Installation related setting 80 37 80 1 C 01 Installation related setting 25 25 37 1 C 02 Not applicable Do not change the default value 20 18 22 1 C 03 Not applicable Do not change the default value 5 5 18 1 C d Domestic water heating retention times 00 Installation related setting 10 5 2...

Страница 20: ...more information If the supply cord is damaged it must be replaced by the manufacturer its agent or similar qualified persons in order to avoid hazards During longer periods of standstill e g during summer with a heating only application it is very important NOT TO SWITCH OFF THE POWER SUPPLY towards the unit Switching off the power supply stops the automatic repetitive movement of the pump in ord...

Страница 21: ...4PEN402192 1B_2017_09 book Page 1 Friday October 6 2017 8 45 PM ...

Страница 22: ...4PEN402192 1B_2017_09 book Page 2 Friday October 6 2017 8 45 PM ...

Страница 23: ...4PEN402192 1B_2017_09 book Page 1 Friday October 6 2017 8 45 PM ...

Страница 24: ...4P402192 1B 2017 09 Copyright 2015 Daikin 4P402192 1 B 0000000W 4PEN402192 1B_2017_09 book Page 1 Friday October 6 2017 8 45 PM ...

Отзывы: