14
|
Troubleshooting
Installer reference guide
183
ERLA EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1B – 2021.10
14.4.1 Error codes: Overview
Error codes of the unit
Error codes of the outdoor unit
Error code
Detailed error code Description
A1
00
Zero cross detection problem.
Power reset required.
Please contact your dealer.
A5
00
OU: High pressure cooling/
Peak
cut/ freeze protection
problem.
E1
00
OU: PCB defect.
Power reset required.
E3
00
OU: Actuation of high
pressure
switch (HPS).
Please contact your dealer.
E5
00
OU: Overheat of inverter
compressor motor.
Please contact your dealer.
E6
00
OU: Compressor startup
defect.
Please contact your dealer.
E7
00
OU: Malfunction of outdoor
unit fan motor.
Please contact your dealer.
E8
00
OU: Power input overvoltage.
Please contact your dealer.
EA
00
OU: Cool/heat switchover
problem.
Please contact your dealer.
H0
00
OU: Voltage/current sensor
problem.
Please contact your dealer.
H3
00
OU: Malfunction of high
pressure switch (HPS)
Please contact your dealer.