ESIE13-03
|
Part 5. Appendix
5. Thermistors
Page 166
13/05/15
|
Version 2.0
Ground source heat pump
5. Thermistors
Figure 82 - Thermistors
3
2
1
6
9
5
10
8
4
7
WATER
LEAVING
(space heating)
BRINE
LEAVING
DOMESTIC
HOT WATER
OUT
WATER
ENTERING
(space heating)
BRINE
ENTERING
DOMESTIC
COLD WATER
IN
1
R1T IN Outlet water temperature sensor
2
R2T IN BUH Temperature sensor
3
R2T OUT Discharge sensor
4
R3T IN Refrigerant liquid temperature sensor
5
R3T OUT Suction sensor
6
R4T IN Inlet water temperature sensor
7
R4T OUT Two phase sensor
8
R5T IN DHW Tank temperature sensor
9
R5T OUT Brine entering water
10 R6T OUT Brine leaving water
Legend