Страница 1: ...User reference guide Daikin Altherma ground source heat pump English User reference guide Daikin Altherma ground source heat pump EGSQH10S18AA9W...

Страница 2: ...4 Contact helpdesk number 6 3 2 19 5 Energy saving tips 19 6 Maintenance and service 20 6 1 Overview Maintenance and service 20 6 2 To find the contact helpdesk number 20 7 Troubleshooting 20 7 1 Ove...

Страница 3: ...led in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set Th...

Страница 4: ...er interface at a glance 4 2 1 Buttons a e f b d c a HOME PAGES Switches between home pages when you are on a home page Goes to the default home page when you are in the menu structure b MALFUNCTION I...

Страница 5: ...home pages You can use the home pages to read out and change settings that are meant for daily usage What you can see and do on the home pages is described where applicable Depending on your system l...

Страница 6: ...ture main additional Set the space operation mode Menu structure Restrict when automatic changeover is possible To check which space operation mode is currently used 1 Go to one of the following the h...

Страница 7: ...Program schedules Define preset values that are used by the room temperature schedule and when you change the mode from scheduled to preset value See also Using the room temperature home page on page...

Страница 8: ...ily overrule the room temperature schedule 1 Go to the room temperature home page Room 2 Use or to adjust the temperature To change the mode from scheduled to preset value Prerequisite User profile De...

Страница 9: ...owing 1 Set the overrule period Temperature lock to 6 hours 2 At 20 00 go to the room temperature home page Room 3 Press to select Result The preset value Comfort will be used until 02 00 After that t...

Страница 10: ...ted it is recommended to program the start up of the disinfection function at least 4 hours later than the last expected large hot water tapping This start up can be set by installer settings disinfec...

Страница 11: ...hedule Only for field supplied domestic hot water pump for secondary return Program a domestic hot water pump schedule to determine when to turn ON and OFF the pump When turned ON the pump runs and ma...

Страница 12: ...u need hot water for 3 persons Then you can do the following 1 Go to the DHW tank temperature home page Tank 2 Overrule the next scheduled action by doing one of the following Change from 55 C to 60 C...

Страница 13: ...es is activated Holiday mode Away is activated but NOT running yet Holiday mode Home is activated You cannot see if the holiday mode is already running If is displayed Then 15 20 Mon Holiday Until Act...

Страница 14: ...ion Room tank or DHW and outside temperature 6 2 Energy metering Produced energy consumed electricity and consumed gas 6 3 Error handling Error history and contact helpdesk number 6 4 User permission...

Страница 15: ...et value Example Room temperature 3 Select a preset value and press Example Comfort heating 4 Select a temperature and press Possible preset values Control Preset value Where used Room temperature Com...

Страница 16: ...day Friday Saturday Sunday To program the schedule 1 Go to 7 3 1 1 User settings Set schedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for m...

Страница 17: ...8 00 23 00 Predefined 2 Mon Fri 07 00 09 00 17 00 12 00 23 00 14 00 Sat Sun 08 00 23 00 Predefined 3 Mon Sun 08 00 23 00 4 7 6 Predefined schedules DHW tank temperature a Start production of domestic...

Страница 18: ...n mode Unit of measurement Holiday Holiday mode From Until Holiday 2 Away Consumed elec Produced energy Energy metering 6 2 Error history Contact helpdesk number Error information 6 3 User interface I...

Страница 19: ...de 1 Weather dep Set weather dependent heating 20 15 60 25 Leaving water temperature Additional zone A 3 1 2 LWT setpoint mode 1 Weather dep Set weather dependent heating 25 60 15 20 Leaving water tem...

Страница 20: ...s for refrigerant leaks may be required depending on the applicable legislation Please contact your installer for more information 6 2 To find the contact helpdesk number Go to 6 3 2 Information Error...

Страница 21: ...pose parts of your system user interface indoor unit outdoor unit DHW tank contact your installer You can find the contact helpdesk number via the user interface 10 Glossary DHW Domestic hot water Hot...

Страница 22: ......

Страница 23: ......

Страница 24: ...4P351749 1 2013 06 Copyright 2013 Daikin...