background image

User reference guide 

Daikin Altherma 3 M

EBLA09~16DAV3
EBLA09~16DAW1
EBLA09~16DA3V3
EBLA09~16DA3W1

EDLA09~16DAV3
EDLA09~16DAW1
EDLA09~16DA3V3
EDLA09~16DA3W1

Содержание EBLA09DAV3

Страница 1: ...User reference guide Daikin Altherma 3 M EBLA09 16DAV3 EBLA09 16DAW1 EBLA09 16DA3V3 EBLA09 16DA3W1 EDLA09 16DAV3 EDLA09 16DAW1 EDLA09 16DA3V3 EDLA09 16DA3W1...

Страница 2: ...change the desired room temperature 28 5 6 5 To change the desired leaving water temperature 29 5 7 Domestic hot water control 30 5 7 1 About domestic hot water control 30 5 7 2 Reheat mode 31 5 7 3...

Страница 3: ...3 M 4P620245 1A 2021 02 8 6 Symptom The system is making gurgling noises after commissioning 58 9 Relocation 60 9 1 Overview Relocation 60 10 Disposal 61 11 Glossary 62 12 Installer settings Tables to...

Страница 4: ...l Quick guide for basic usage Format Paper in the box of the outdoor unit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital...

Страница 5: ...screen press the help button The breadcrumbs appear in the top left corner of the screen 2 To disable the breadcrumbs Press the help button again This document also mentions these breadcrumbs Example...

Страница 6: ...uation that could result in equipment or property damage INFORMATION Indicates useful tips or additional information Symbols used on the unit Symbol Explanation Before installation read the installati...

Страница 7: ...hysical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards i...

Страница 8: ...be mixed with unsorted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible che...

Страница 9: ...e the room and contact the dealer where you purchased the unit Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired WARNING Air purging...

Страница 10: ...ls INFORMATION If underfloor heating is installed in the main zone then in cooling mode the main zone can only provide refreshment Real cooling is then NOT allowed 3 1 Components in a typical system l...

Страница 11: ...hrough the list of digits and change the selected digit Move the cursor from left to right Confirm the pin code and proceed User pin code The User pin code is 0000 0000 User Advanced user pin code The...

Страница 12: ...C 2 2 Set operation to On or Off To change the desired room temperature During room temperature control you can use the room temperature setpoint screen to read out and adjust the desired room temper...

Страница 13: ...Additional zone Cooling 3 6 Additional zone Cooling WD curve 2 Change the weather dependent curve There are 2 types of WD curves slope offset curve default and 2 points curve If needed you can change...

Страница 14: ...fset Confirm changes and return to the submenu 2 points curve Y1 Y2 X1 X2 X1 X2 Outdoor ambient temperature Y1 Y2 Desired leaving water temperature Possible actions on this screen Go through the tempe...

Страница 15: ...Off To change the tank temperature setpoint In Reheat only mode you can use the tank temperature setpoint screen to read out and adjust the domestic hot water temperature 1 Go to 5 Tank Tank 5 2 Adju...

Страница 16: ...onnector With a USB memory stick the installer can Update the software This requires a correct config file on the USB memory stick Import the settings generated by E Configurator Heating Solutions Nav...

Страница 17: ...your choice or go to a submenu b Back button Press to go back 1 step in the menu structure c Home button Press to go back to the home screen d Help button Press to show a help text related to the curr...

Страница 18: ...4 Quiet Activation Schedule Level 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 4 Space heating cooling Operation mode Operation mode schedule Room comfort setpoi...

Страница 19: ...reen with weather dependent curve c4 Screen with schedule 5 3 1 Home screen Press the button to go back to the home screen You see an overview of the unit configuration and the room and setpoint tempe...

Страница 20: ...eat pump failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is...

Страница 21: ...floor heating Fancoil unit Radiator i3 21 Measured room temperature a i4 35 Leaving water temperature setpoint a j Holiday mode Holiday mode active k Additional zone k1 Installed room thermostat type...

Страница 22: ...fort Interface BRC1HHDA used as room thermostat is controlling the outdoor unit Set the room temperature 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving water t...

Страница 23: ...in Residential Controller app 5 3 3 Setpoint screen The setpoint screen is displayed for screens describing system components that need a setpoint value Examples 1 Room temperature screen 21 C 1 Room...

Страница 24: ...30 Minutes a Settings b Values c Selected setting and value Possible actions on this screen Go through the list of settings Change the value Go to the next setting Confirm changes and proceed 5 4 Turn...

Страница 25: ...ternal room thermostat control the protection is NOT guaranteed NOTICE Water pipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe...

Страница 26: ...mode 8 7 About Version information about the system 8 8 Connection status Information about the connection status of the unit the room thermostat and WLAN 8 9 Running hours Running hours of specific...

Страница 27: ...ating mode the icon is shown When the unit is in cooling mode the icon is shown The status indicator shows if the unit is currently in operation When the unit is not in operation the status indicator...

Страница 28: ...using method 2 You can see on the home screen which temperature control you are using 6 22 19 55 21 35 45 a2 a1 b 18 Feb 2020 a1 Heat emitter of the main zone in this example Underfloor heating a2 Hea...

Страница 29: ...You can avoid scheduled behaviour by temporarily turning off scheduling To turn off room temperature scheduling 1 Go to 1 1 Room Schedule 2 Select No 5 6 5 To change the desired leaving water temperat...

Страница 30: ...he following 2 1 Main zone Schedule 3 1 Additional zone Schedule 2 Select No To enable weather dependent operation for the leaving water temperature See 5 9 4 Using weather dependent curves 447 5 7 Do...

Страница 31: ...ank the tank temperature is determined automatically by the outdoor temperature For more information see 5 9 Weather dependent curve 444 To determine which domestic hot water mode you are using method...

Страница 32: ...C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time Initially the DHW tank temperature is the same as the temperature of the domestic water entering the DHW tank example 15 C At 00 00...

Страница 33: ...setpoint screen but not modify it Instead you can modify the settings for the Comfort setpoint 5 2 Eco setpoint 5 3 and Reheat setpoint 5 4 When weather dependent operation is used for the tank the t...

Страница 34: ...time then reuse the values in other screens such as the scheduling screen If you later want to change the value you only have to do it in one place Possible preset values You can set the following us...

Страница 35: ...schedules You can Consult which schedule is currently selected Schedule Control in Possible schedules 435 Select another schedule if needed To select which schedule you currently want to use 435 Progr...

Страница 36: ...3 Activation screen 1 1 Schedule Possible actions Temperatures within range 1 3 Room Cooling schedule Schedule for the desired room temperature in cooling mode Predefined schedules 1 Activation scree...

Страница 37: ...your normal domestic hot water needs Predefined schedules 1 Activation screen Not applicable This schedule is automatically activated if the DHW mode is one of the following Schedule only Schedule reh...

Страница 38: ...ater operation allowed 5 8 3 Schedule screen Example This example shows how to set a room temperature schedule in heating mode for the main zone INFORMATION The procedures to program other schedules a...

Страница 39: ...Fri Thu Tue Sun User defined 1 2 Select Delete Delete Rename Select 3 Select OK to confirm To clear the content of a day schedule 1 Select the day of which you want to clear the content For example Fr...

Страница 40: ...action set its time as the time of the previous action 4 Confirm the changes Result The schedule for Monday is defined The value of the last action is valid until the next programmed action In this ex...

Страница 41: ...n for all other weekdays Mon Sat Wed Fri Thu Tue Sun User defined 1 C To program the schedule for Saturday and copy it to Sunday 1 Select Saturday 2 Select Edit 3 Use the left dial to select an entry...

Страница 42: ...ers 5 Confirm the new name INFORMATION Not all schedules can be renamed Usage example You work in a 3 shift system If you work in a 3 shift system you can do the following 1 Program 3 room temperature...

Страница 43: ...city supplier 3 Confirm the changes INFORMATION The values correspond with the electricity price values for High Medium and Low previously set If no schedule is set the electricity price for High is t...

Страница 44: ...es weather dependent if the desired leaving water or tank temperature is determined automatically by the outdoor temperature It therefore is connected to a temperature sensor on the North wall of the...

Страница 45: ...4 Using weather dependent curves 447 Availability The weather dependent curve is available for Main zone Heating Main zone Cooling Additional zone Heating Additional zone Cooling Tank only available t...

Страница 46: ...t Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the leaving water for different ambient temperatures For example if...

Страница 47: ...ing Main zone or additional zone cooling Domestic hot water X1 X2 Examples of outdoor ambient temperature Y1 Y2 Y3 Y4 Examples of desired tank temperature or leaving water temperature The icon corresp...

Страница 48: ...type for all zones main additional and for the tank go to 2 E Main zone WD curve type Viewing which type is selected is also possible via 3 C Additional zone WD curve type 5 E Tank WD curve type Restr...

Страница 49: ...eratures Slope Offset OK Cold OK Hot Cold OK Cold Cold Cold Hot Hot OK Hot Cold Hot Hot To fine tune the weather dependent curve 2 points curve The following table describes how to fine tune the weath...

Страница 50: ...ion Only possible if enabled by the installer 1 Go to 7 4 2 User settings Quiet Schedule 2 Program the schedule Possible actions You can use the following system defined preset values Quiet More quiet...

Страница 51: ...3 Set the last day of your holiday Go to 7 3 3 Till Select a date Confirm the changes 5 10 4 Using WLAN INFORMATION Restriction WLAN settings are only visible when a WLAN cartridge is inserted in the...

Страница 52: ...access point 1 Go to D 1 Wireless gateway Mode 2 In the Enable AP mode screen select Yes D 2 Reboot Reboot the WLAN cartridge 1 Go to D 2 Wireless gateway Reboot 2 In the Reboot the gateway screen se...

Страница 53: ...BLA09 16DA EDLA09 16DA Daikin Altherma 3 M 4P620245 1A 2021 02 D 6 Cloud connection Read out the status of the connection to the cloud 1 Go to D 6 Wireless gateway Cloud connection 2 Read out the conn...

Страница 54: ...are leaving for a couple of hours For longer periods You can use the holiday mode Tips about leaving water temperature In heating mode a lower desired leaving water temperature results in lower energ...

Страница 55: ...erant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING MILDLY FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING The applianc...

Страница 56: ...f a malfunction the following will appear on the home screen depending on the severity Error Malfunction You can get a short and a long description of the malfunction as follows 1 Press the left dial...

Страница 57: ...mitter type See 5 6 5 To change the desired leaving water temperature 429 The weather dependent curve is set incorrectly Adjust the weather dependent curve See 5 9 Weather dependent curve 444 8 4 Symp...

Страница 58: ...reduced but domestic hot water is still available auto SH reduced DHW off space heating is reduced and domestic hot water is NOT available auto SH normal DHW off space heating operates as normally but...

Страница 59: ...air purge function of the unit to be performed by the installer If you purge air from the heat emitters or collectors mind the following WARNING Air purging heat emitters or collectors Before you purg...

Страница 60: ...16DA Daikin Altherma 3 M 4P620245 1A 2021 02 9 Relocation 9 1 Overview Relocation If you want to relocate parts of your system contact your installer You can find the contact helpdesk number via the u...

Страница 61: ...0245 1A 2021 02 10 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units...

Страница 62: ...Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application explaining...

Страница 63: ...9 2 1 Emergency 9 5 Number of zones 4 4 Glycol Filled system overview field setting E 0D Booster heater capacity 9 4 1 if applicable Backup heater Voltage 9 3 2 Configuration 9 3 3 Capacity step 1 9...

Страница 64: ...herma 3 M 4P620245 1A 2021 02 Setting Fill in Heat up mode 5 6 Comfort setpoint 5 2 Eco setpoint 5 3 Reheat setpoint 5 4 Setpoint mode 5 B WD curve type 5 E read only 12 2 Settings menu Setting Fill i...

Страница 65: ......

Страница 66: ......

Страница 67: ......

Страница 68: ...4P620245 1A 2021 02 Copyright 2020 Daikin Verantwortung f r Energie und Umwelt...

Отзывы: