14. Flow switch
The flow switch checks the flow in the water circuit and protects
the heat exchanger against freezing and the pump against
damage.
15. Pump
The pump circulates the water in the water circuit.
16. Backup heater thermal protector
The backup heater is equipped with a thermal protector. The
thermal protector is activated when the temperature becomes
too high.
17. Backup heater thermal fuse
The backup heater is equipped with a thermal fuse. The thermal
fuse is blown when the temperature becomes too high (higher
than the backup heater thermal protector temperature).
18. Pressure relief valve
The pressure relief valve prevents excessive water pressure in
the water circuit by opening at 3 bar and discharging some
water.
Functional diagram of hydraulic compartment (door 3)
Switch box main components (door 2)
1.
Backup heater contactors K1M and K5M
2.
Main PCB
The main PCB (Printed Circuit Board) controls the functioning of
the unit.
3.
Booster heater contactor K3M (only for installations with
domestic hot water tank)
4.
Booster heater circuit breaker F2B (only for installations with
domestic hot water tank)
The circuit breaker protects the booster heater in the
domestic
hot
water tank against overload or short circuit.
5.
Backup heater circuit breaker F1B
The circuit breaker protects the backup heater electrical circuit
against overload or short circuit.
6.
Terminal blocks
The terminal blocks allow easy connection of field wiring.
7.
Terminal block for backup heater capacity limitation.
8.
Cable tie mountings
The cable tie mountings allow to fix the field wiring with cable
ties to the switch box to ensure strain relief.
9.
Terminal blocks X3M, X4M (only for installations with domestic
hot water tank)
10. PCB fuse FU1
11. DIP switch SS2
The DIP switch SS2 provides 4 toggle switches to configure
certain installation parameters. See
12. X13A socket
The X13A socket receives the K3M connector (only for
installations with domestic hot water tank).
1
Expansion vessel
8
Heat exchanger
2
Manometer
9
Flow switch
3
Air purge valve
10
Drain/fill valve
4
Pressure relief valve
11
Filter
5
Backup heater vessel
with backup heater
12
Shut-off valve water inlet with
drain valve
6
Pump
R11T
R12T
R13T
R14T
Temperature sensors
7
Shut-off valve water
outlet
R14T
H
2
O
t >
R13T
t >
R12T
t >
R11T
t >
1
2
6
7
12
8
9
10
11
3 4
5
3
1
2
1
24
5
4
6
7
16
17
12
X13A
14
FU2
13
X9A
6
8
10
FU1
18
9
9
8
15
8
23
21
20
22
19
8
11
SS2
A
C
B
D
A
B
D
C
25
Содержание EBHQ011BA6V3
Страница 47: ...NOTES NOTES ...
Страница 48: ...4PW57621 1A Copyright Daikin ...