background image

4 Operation

Operation manual

6

EABH/X16DF6V(7)+9W(7) + EAVH/

X16S(U)18+23DA6V(7)+9W(7)

Daikin Altherma 3 H F+W

4P644480-1A – 2021.09

Item

Description

Indoor unit /

domestic

hot water

tank

b1

b2

b1

Indoor unit:

: Floor-standing indoor unit with integrated

tank

: Wall-mounted indoor unit with separated

tank

: Wall-mounted indoor unit

b2

Water pressure

Space

operation

mode

c

: Cooling

: Heating

Disinfection

 / Powerful

d

: Disinfection mode active

: Powerful operation active

Date / time

e

Current date and time

Holiday

f

: Holiday mode active

Main zone

g3

g1

g4

g2

g1

Heat emitter type:

Underfloor heating

Fancoil unit

Radiator

g2

Leaving water temperature setpoint

g3

Room thermostat type:

:  Daikin  user  interface  used  as  room

thermostat

: External control

▪ Hidden: Leaving water temperature control

g4

Measured room temperature

Additional

zone

h3

h1

h2

h1

Heat emitter type:

Underfloor heating

Fancoil unit

Radiator

h2

Leaving water temperature setpoint

h3

Room thermostat type:

: External control

▪ Hidden: Leaving water temperature control

Domestic

hot water

i1

i2

i1

: Domestic hot water

i2

Measured tank temperature

Malfunction

j

 or 

: A malfunction occurred

See 

"7.1 To display the help text in case of a

malfunction"

 [

4

 15] for more information.

4.2.2

Main menu screen

Starting from the home screen, press (

) or turn (

) the

left dial to open the main menu screen. From the main menu, you

can access the different setpoint screens and submenus.

a

2

Main zone

Additional zone

Room

Malfunctioning

Space heating/cooling

a

Selected submenu

Possible actions on this screen

Go through the list.
Enter the submenu.
Enable/disable breadcrumbs.

Submenu

Description

[0]

 or 

Malfunctioning

Restriction: 

Only displayed if a

malfunction occurs.
See 

"7.1 To display the help text in

case of a malfunction"

 [

4

 15] for more

information.

[1]

 

Room

Restriction: 

Only displayed if a room

thermostat is connected to the indoor

unit.
Set the room temperature.

[2]

 

Main zone

Shows the applicable symbol for your

main zone emitter type.
Set the leaving water temperature for

the main zone.

[3]

 

Additional zone

Restriction: 

Only displayed if there

are two leaving water temperature

zones. Shows the applicable symbol

for your additional zone emitter type.
Set the leaving water temperature for

the additional zone (if present).

[4]

 

Space heating/

cooling

Shows the applicable symbol for your

unit.
Put the unit in heating mode or cooling

mode. You cannot change the mode

on heating only models.

[5]

 

Tank

Restriction: 

Only displayed if a

domestic hot water tank is present.
Set the domestic hot water tank

temperature.

[7]

 

User settings

Gives access to user settings such as

holiday mode and quiet mode.

[8]

 

Information

Displays data and information about

the indoor unit.

[9]

 

Installer

settings

Restriction: 

Only for the installer.

Gives access to advanced settings.

[A]

 

Commissioning

Restriction: 

Only for the installer.

Perform tests and maintenance.

[B]

 

User profile

Change the active user profile.

[C]

 

Operation

Turn heating/cooling functionality and

domestic hot water preparation on or

off.

4.2.3

Setpoint screen

The  setpoint  screen  is  displayed  for  screens  describing  system

components that need a setpoint value.

Содержание Daikin Altherma 3 H F+W

Страница 1: ...ration manual Daikin Altherma 3 H F W EABH16DF6V 7 EABH16DF9W 7 EABX16DF6V 7 EABX16DF9W 7 EAVH16S18DA6V 7 EAVH16S23DA6V 7 EAVH16S18DA9W 7 EAVH16S23DA9W 7 EAVX16S18DA6V 7 EAVX16S23DA6V 7 EAVX16S18DA9W...

Страница 2: ...Check if he has filled in the installer settings tables If NOT request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a d...

Страница 3: ...refrigerant of oil and of other parts MUST be done by an authorised installer and MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling...

Страница 4: ...the heat emitters or collectors 3 About the system Depending on the system layout the system can Heat up a space Cool down a space if a heating cooling heat pump model is installed Produce domestic ho...

Страница 5: ...to show a help text related to the current page if available e Right dial The LCD shows an arc on the right side of the display when you can use the right dial Turn then press the right dial Change a...

Страница 6: ...Space heating cooling a Selected submenu Possible actions on this screen Go through the list Enter the submenu Enable disable breadcrumbs Submenu Description 0 or Malfunctioning Restriction Only displ...

Страница 7: ...4 Detailed screen with values Example a b c a b c 7 2 1 Time date Hours 11 30 Minutes a Settings b Values c Selected setting and value Possible actions on this screen Go through the list of settings...

Страница 8: ...on mode to use To tell the system which space operation to use you can You can Location Check which space operation mode is currently used Home screen Set the space operation mode permanently Main men...

Страница 9: ...FORMATION When the DHW tank mode is reheat the risk for capacity shortage and comfort problem is significant In case of frequent reheat operation space heating cooling function is regularly interrupte...

Страница 10: ...nformation To change the user permission level You can change the user permission level as follows 1 Go to B User profile User profile B 2 Enter the applicable pin code for the user permission level B...

Страница 11: ...ious action 4 Confirm the changes Result The schedule for Monday is defined The value of the last action is valid until the next programmed action In this example Monday is the first day you programme...

Страница 12: ...Thu Tue Sun User defined 1 2 Select Rename Delete Rename Select 3 optional To delete the current schedule name browse through the character list until is displayed then press to remove the previous ch...

Страница 13: ...ule 7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection sta...

Страница 14: ...he scheduled room temperature until the next scheduled action Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about DHW...

Страница 15: ...en 7 2 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See 4 4 2 T...

Страница 16: ...If hydraulic balancing is not sufficient change the pump limitation settings 9 0D and 9 0E if applicable Various malfunctions Check if or is displayed on the home screen of the user interface See 7 1...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...4P644480 1A 2021 09 Copyright 2018 Daikin 4P644480 1 A 0000000 Verantwortung f r Energie und Umwelt...

Отзывы: