Daikin Daikin Altherma 3 H F+W Скачать руководство пользователя страница 10

4 Operation

Operation manual

10

EABH/X16DF6V(7)+9W(7) + EAVH/

X16S(U)18+23DA6V(7)+9W(7)

Daikin Altherma 3 H F+W

4P644480-1A – 2021.09

t

Time

4.5.4

Using DHW powerful operation

About powerful operation

Powerful operation

 allows the domestic hot water to be heated by

the backup heater or booster heater. Use this mode on days when

there is more hot water usage than usual.

To check if powerful operation is active

If 

 is displayed on the home screen, powerful operation is active.

Activate or deactivate 

Powerful operation

 as follows:

1

Go to [5.1]: 

Tank

 > 

Powerful operation

2

Turn powerful operation 

Off

 or 

On

.

Usage example: You immediately need more hot water

You are in the following situation:
▪ You already consumed most of your domestic hot water.
▪ You  cannot  wait  for  the  next  scheduled  action  to  heat  up  the

domestic hot water tank.

Then  you  can  activate  powerful  operation.  The  domestic  hot  water

tank will start heating up the water to the 

Comfort

 temperature.

INFORMATION

When  powerful  operation  is  active,  the  risk  of  space

heating/cooling and capacity shortage comfort problems is

significant.  In  case  of  frequent  domestic  hot  water

operation,  frequent  and  long  space  heating/cooling

interruptions will happen.

4.6

Advanced usage

The  amount  of  information  you  can  read  out  and  edit  in  the  menu

structure depends on your user permission level:

User

: Standard mode

Advanced user

: You can read out and edit more information

To change the user permission level

You can change the user permission level as follows:

1

Go to [B]: 

User profile

.

User profile

B

2

Enter the applicable pin code for the user permission

level.

▪ Browse  through  the  list  of  digits  and  change  the

selected digit.

▪ Move the cursor from left to right.
▪ Confirm the pin code and proceed.

User pin code

The 

User

 pin code is 

0000

.

0000

User

Advanced user pin code

The 

Advanced user

 pin code is 

1234

. Additional menu items for the

user are now visible.

1234

Advanced user

4.7

Schedule screen: Example

This  example  shows  how  to  set  a  room  temperature  schedule  in

heating mode for the main zone.

INFORMATION

The procedures to program other schedules are similar.

To program the schedule: overview
Example: 

You want to program the following schedule:

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

Prerequisite: 

The  room  temperature  schedule  is  only  available  if

room  thermostat  control  is  active.  If  leaving  water  temperature

control is active, you can program the main zone schedule instead.

1

Go to the schedule.

2

(optional) Clear the content of the whole week schedule or the

content of a selected day schedule.

3

Program the schedule for 

Monday

.

4

Copy the schedule to the other weekdays.

5

Program the schedule for 

Saturday

 and copy it to 

Sunday

.

6

Give the schedule a name.

To go to the schedule

1

Go to [1.1]: 

Room

 > 

Schedule

.

2

Set scheduling to 

Yes

.

3

Go to [1.2]: 

Room

 > 

Heating schedule

.

To clear the content of the week schedule

1

Select the name of the current schedule.

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

2

Select 

Delete

.

Delete

Rename
Select

3

Select 

OK

 to confirm.

Содержание Daikin Altherma 3 H F+W

Страница 1: ...ration manual Daikin Altherma 3 H F W EABH16DF6V 7 EABH16DF9W 7 EABX16DF6V 7 EABX16DF9W 7 EAVH16S18DA6V 7 EAVH16S23DA6V 7 EAVH16S18DA9W 7 EAVH16S23DA9W 7 EAVX16S18DA6V 7 EAVX16S23DA6V 7 EAVX16S18DA9W...

Страница 2: ...Check if he has filled in the installer settings tables If NOT request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a d...

Страница 3: ...refrigerant of oil and of other parts MUST be done by an authorised installer and MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling...

Страница 4: ...the heat emitters or collectors 3 About the system Depending on the system layout the system can Heat up a space Cool down a space if a heating cooling heat pump model is installed Produce domestic ho...

Страница 5: ...to show a help text related to the current page if available e Right dial The LCD shows an arc on the right side of the display when you can use the right dial Turn then press the right dial Change a...

Страница 6: ...Space heating cooling a Selected submenu Possible actions on this screen Go through the list Enter the submenu Enable disable breadcrumbs Submenu Description 0 or Malfunctioning Restriction Only displ...

Страница 7: ...4 Detailed screen with values Example a b c a b c 7 2 1 Time date Hours 11 30 Minutes a Settings b Values c Selected setting and value Possible actions on this screen Go through the list of settings...

Страница 8: ...on mode to use To tell the system which space operation to use you can You can Location Check which space operation mode is currently used Home screen Set the space operation mode permanently Main men...

Страница 9: ...FORMATION When the DHW tank mode is reheat the risk for capacity shortage and comfort problem is significant In case of frequent reheat operation space heating cooling function is regularly interrupte...

Страница 10: ...nformation To change the user permission level You can change the user permission level as follows 1 Go to B User profile User profile B 2 Enter the applicable pin code for the user permission level B...

Страница 11: ...ious action 4 Confirm the changes Result The schedule for Monday is defined The value of the last action is valid until the next programmed action In this example Monday is the first day you programme...

Страница 12: ...Thu Tue Sun User defined 1 2 Select Rename Delete Rename Select 3 optional To delete the current schedule name browse through the character list until is displayed then press to remove the previous ch...

Страница 13: ...ule 7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection sta...

Страница 14: ...he scheduled room temperature until the next scheduled action Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about DHW...

Страница 15: ...en 7 2 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See 4 4 2 T...

Страница 16: ...If hydraulic balancing is not sufficient change the pump limitation settings 9 0D and 9 0E if applicable Various malfunctions Check if or is displayed on the home screen of the user interface See 7 1...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...4P644480 1A 2021 09 Copyright 2018 Daikin 4P644480 1 A 0000000 Verantwortung f r Energie und Umwelt...

Отзывы: