Daikin BACnet MT3041 Скачать руководство пользователя страница 1

Installation and Maintenance 

IM 916-5

Group: 

Controls

Part Number: 

IM 916

Date: 

August 2020

BACnet

®

 IP Communication Module for  

MicroTech

®

 III and MicroTech

®

 4 Unit Controllers 

Applied Rooftop Systems and Self-Contained Units

Models: DPS, DPH, MPS, RAH, RCE, RCS, RDE, RDS, RDT, RFS, RPE, 

RPS, SWP and SWT 

Содержание BACnet MT3041

Страница 1: ...Controls Part Number IM 916 Date August 2020 BACnet IP Communication Module for MicroTech III and MicroTech 4 Unit Controllers Applied Rooftop Systems and Self Contained Units Models DPS DPH MPS RAH...

Страница 2: ...ht Emitting Diodes LEDs 5 BACnet Network Connector 5 Board to Board Connector 5 Installation 6 Installation and Mounting 6 Field Installation Kit 6 Installing a new Communication Module 6 Replacing a...

Страница 3: ...ath or serious injury if not avoided NOTICE Notices give important information concerning a process procedure special handling or equipment attributes Revision History IM 916 Oct 2008 Initial release...

Страница 4: ...ture numbers and locations Specifications General Dimensions W x H x D 1 77 x 4 33 x 2 95 in 45 x 110 x 75 mm Weight 3 5 oz 98 g Material Base plastic pigeon blue Housing plastic light gray Operating...

Страница 5: ...lashing with 2Hz Software error1 Red Hardware error1 1 In the event that this should occur cycle power to the unit controller to attempt to clear the problem Contact the Controls Customer Support Grou...

Страница 6: ...tool to the tab on the bottom of the unit controller and pull the screwdriver away from the controller 5 Carefully remove the blue plastic knockout on the far right side of the BACnet communication m...

Страница 7: ...tered a password skip to step 3 2 Enter Password 6363 3 Continue to navigate to the BMS Communications BACnet IP Set Up menu NOTE The IP Setup menu only appears if a BACnet communication module instal...

Страница 8: ...t Mask Gvn Msk provided the network is connected when Apply Changes is set to Yes Act Gwy If DHCP set to On Address automatically assigned by network If DHCP set to Off Address Given Gateway Address A...

Страница 9: ...nfirm that the DHCP parameter is set to Off when a static IP address is being used for non DHCP networks Check that the defined UDP port e g BAC0 is open in the firewall Verify if BBMDs are required B...

Страница 10: ...dentifier or their BACnet address The IP address is part of the BACnet address and may not be changed for the alarm recipient For this reason option Device Object Identifier must always be used Access...

Страница 11: ......

Страница 12: ...nt to its standard terms and conditions of sale including Limited Product Warranty Consult your local Daikin Applied Representative for warranty details To find your local Daikin Applied Representativ...