6
|
Unit installation
Installer reference guide
28
35AMV1B35AMV1B
Daikin room air conditioner
4P513661-10K – 2021.07
a
b
a
b
a
Insulation fixing screw
b
Drain hose
4
Attach the drain hose to the refrigerant piping bottom side using adhesive
vinyl tape.
A
B
C
b
a
A
Left-side piping
B
Left-back piping
C
Left-bottom piping
a
Remove the pipe port cover here for left-side piping
b
Remove the pipe port cover here for left-bottom piping
6.4.4 To check for water leaks
1
Remove the air filters.
2
Gradually pour approximately 1 l of water in the drain pan, and check for